SAFETY RULES

SAFETY RULES

POWERGRIP  power  console  should  be  connected  directly  to  the 
stationary  grounded  outlet  of  the  power  network.  Do  not  connect 
console  in  parallel  (i.e.  daisy  chain  connection)  to  other  electrical 
devices, such as power supply protection devices, power filters or 
UPS. Do not use extension cords or T-connectors. Non-compliance 
with these requirements may cause injuries or equipment damage, 
which  will  automatically  incur  warranty  termination.  If  you  are  not 
sure which power outlet is duly grounded, consult a competent elec-
trician.

Although POWERGRIP console is intended for considerable current 
surges,  it  is  recommended  to  unplug  the  device  in  case  of  heavy 
thunderstorm. To disconnect the equipment connected to the con-
sole is not necessary.

Avoid water ingress in the console or the housing. In case of water 
ingress  disconnect  the  console  from  the  power  outlet.  Use  the 
device only idoors. Do not use the console in the rooms with high 
humidity.

In case any problems in console operation or its complete damage 
may  occur,  do  not  try  to  remedy  them  unassisted.  It  may  cause 
serious  injuries  or  death.  Do  not  dissemble  the  console.  This  will 
automatically  incur  warranty  termination.  Disconnect  the  console 
from the network immediately and contact autorized . The manufac-
turer is not liable for console functioning and reparation of unauthor-
ized  interference  effects  if  the  maintenance  was  performed  in  an 
uncertified service center.

Содержание YG-2

Страница 1: ...OPERATION MANUAL YG 2 CLEAN POWER CONSOLE...

Страница 2: ...e through large current impulses unlike traditional power filters Switching relays operate using Zero cross technology switching on and off the load is performed while crossing zero point supply volta...

Страница 3: ...ts Energy indicator in Joules 2 220 J Maximum peak current 65 000 A Limits at which emergency shutdown of power supply occurs 190 256 V may vary depending on harmonic distortion in the network as well...

Страница 4: ...Correct switching indicator lights up in case of correct plug ging of equipment in the outlet Phase of the outlet must be on the left while the power cable is directed downwards If the indicator does...

Страница 5: ...pes of filters see the Equipment connection section 9 Trigger signals input is intended for switching on and off the console by the signal from another device RS232 signal trans mission by means of an...

Страница 6: ...to the outlets of the first or the second group thus providing reliable seg regation of the interference emitted by digital power modules If you are not able to determine what kind of power module is...

Страница 7: ...it is recommended to unplug the device in case of heavy thunderstorm To disconnect the equipment connected to the con sole is not necessary Avoid water ingress in the console or the housing In case of...

Страница 8: ...ss bring the hand close to the screen 10 15 mm 2 Light touch with one finger The action is assigned via the menu 3 Light touch with two fingers activates the second group it can be deactivated via the...

Страница 9: ...the power button for some time with switched off automatic restarting ES Automatic restarting of permanently operating outlets after protection activation This menu item is accessible only when at le...

Страница 10: ...er touch see Measurement mode and the second group activation by two fingers touch To save the settings you need to go through the menu to the end MEASUREMENT MODE To switch to measurement mode the fo...

Страница 11: ......

Страница 12: ...n Federation Assembled in Taiwan Manufacturer AO Barnsly Import Office 10 3 bld 1 Signalny Proezd Moscow 127106 Russia www powergrip com For detailed information on port RS232 application for control...

Отзывы: