background image

POWERFIX PDM 250 A2 

English - 33 

Replacing the fuse 

To replace the fuse, proceed as follows: 

 

Switch off the multimeter and remove all test leads before opening the multimeter! 

 

Remove the holster [2]. 

 

Remove the two screws on the back of the multimeter and remove the back panel. 

 

 

Replace faulty fuse F1 (F 250mA / 250V) or F2 (F 10A / 250V) with a new one of the 

same type. 

 

 

Replace the back panel and screw it tight with the two screws. 

 

Re-insert the multimeter in the holster [2]. 

Содержание 108029

Страница 1: ......

Страница 2: ......

Страница 3: ...V 2 3 Deutsch 2 English 19...

Страница 4: ...11 Gleichspannungsmessung DC 11 Wechselspannungsmessung AC 11 Wechselstrommessung AC 12 Gleichstrommessung DC 12 Batterietest 13 Widerstandsmessung 13 Durchgangspr fung 14 Diodentest 14 HOLD Funktion...

Страница 5: ...Multimeter ist nicht f r den Betrieb in einem Unternehmen bzw den gewerblichen Einsatz vorgesehen Verwenden Sie dieses Multimeter ausschlie lich f r den privaten Gebrauch jede andere Verwendung ist ni...

Страница 6: ...einem ausklappbaren Umschlag versehen Auf der Innenseite des Umschlags ist das Multimeter mit einer Bezifferung abgebildet Die Ziffern haben folgende Bedeutung 1 Display 2 Holster 3 HOLD Taste Speich...

Страница 7: ...atur Luftfeuchte 0 C bis 40 C max 75 rel Feuchte Lagertemperatur Luftfeuchte 10 C bis 50 C max 85 rel Feuchte Abmessungen B x H x T 85 x 164 x 35 mm ohne Holster 93 x 178 x 52 mm mit Holster Gewicht 2...

Страница 8: ...mA 0 1mA 10A 10mA 2 0 5 berlastungsschutz F1 F 250mA 250V Sicherung F2 F 10A 250V Sicherung Maximaler Eingangsstrom 10A Eingangsstrom 2A f r kontinuierliche Messung 15 Sek und Intervall 15 Min Wechsel...

Страница 9: ...n 75 gew hrleistet Sicherheitshinweise Vor der ersten Verwendung des Multimeters lesen Sie die folgenden Anweisungen genau durch und beachten Sie alle Warnhinweise selbst wenn Ihnen der Umgang mit ele...

Страница 10: ...sundheitssch dlich sein Die Messspitzen d rfen nur hinter den Fingerschutzkragen angefasst werden sonst besteht beim Messen Gefahr durch Stromschlag Bei Besch digungen des Multimeters oder der Messspi...

Страница 11: ...izungen oder keinem direkten Sonnenlicht oder Kunstlicht ausgesetzt werden Vermeiden Sie auch den Kontakt mit Spritz und Tropfwasser und aggressiven Fl ssigkeiten Betreiben Sie das Multimeter nicht in...

Страница 12: ...t das Symbol im Display 1 F r eine ordnungsgem e Funktion sollte die Batterie bei n chster Gelegenheit gewechselt werden Entfernen Sie das Holster 2 L sen Sie die zwei Schrauben an der R ckseite des M...

Страница 13: ...m glich sofort in einen h heren Messbereich oder entfernen Sie die Messspitzen 7 vom Messobjekt Gleichspannungsmessung DC Verbinden Sie die schwarze Messleitung mit dem COM Anschluss 5 und die rote M...

Страница 14: ...ich ein und wechseln Sie dann nach und nach in die niedrigeren Bereiche bis ein zufriedenstellendes Messergebnis vorliegt Verbinden Sie die Messspitzen 7 in Reihe mit dem Messobjekt Das Messergebnis w...

Страница 15: ...nte sowie andere Messobjekte unbedingt spannungslos und entladen sind Andernfalls k nnte das Multimeter besch digt werden Verbinden Sie die schwarze Messleitung mit dem COM Anschluss 5 und die rote Me...

Страница 16: ...haltungsteile Schaltungen und Bauelemente sowie andere Messobjekte unbedingt spannungslos und entladen sind Andernfalls k nnte das Multimeter besch digt werden Verbinden Sie die schwarze Messleitung m...

Страница 17: ...auf der R ckseite des Holsters 2 aus Weiterhin befindet sich oberhalb des Aufstellers eine Aussparung um das Multimeter aufh ngen zu k nnen Wartung Reinigung Wartung Wartungsarbeiten sind erforderlich...

Страница 18: ...das Multimeter ffnen Entfernen Sie das Holster 2 L sen Sie die zwei Schrauben an der R ckseite des Multimeters und entfernen Sie die R ckwand Tauschen Sie die defekte Sicherung F1 F 250mA 250V oder F2...

Страница 19: ...m Entsorgungsamt oder in dem Gesch ft in dem Sie das Ger t erworben haben Denken Sie an den Umweltschutz Verbrauchte Batterien geh ren nicht in den Hausm ll Sie m ssen bei einer Sammelstelle f r Altba...

Страница 20: ...ird durch unsere Hotline in Abh ngigkeit der Fehlerursache ein weiterf hrender Service veranlasst In der Garantie wird das Produkt bei Material oder Fabrikationsfehler nach unserer Wahl kostenlos repa...

Страница 21: ...voltage measurement 28 AC voltage measurement 28 AC current measurement 29 DC current measurement 29 Battery test 29 Resistance measurement 30 Continuity test 30 Diode test 31 HOLD function 31 One ha...

Страница 22: ...igned for commercial use or installation and operation in a company This multimeter may only be used for private purposes and any other use is not as intended This multimeter meets all relevant norms...

Страница 23: ...These instructions have a fold out cover The multimeter is illustrated with a numbering system on the inside of the cover The numbers indicate the following 1 Screen 2 Holster 3 HOLD button Save butto...

Страница 24: ...function yes Operating temperature air humidity 0 C to 40 C max 75 rel humidity Storage temperature air humidity 10 C to 50 C max 85 rel humidity Dimensions W x H x D 85 x 164 x 35 mm without holster...

Страница 25: ...0mA 0 1mA 10A 10mA 2 0 5 Overload protection F1 F 250mA 250V fuse F2 F 10A 250V fuse Maximum input current 10A input current 2A for continuous measurement 15 seconds and interval 15 minutes AC current...

Страница 26: ...and maximum air humidity of 75 Safety instructions Before using this multimeter for the first time always read the following instructions and pay attention to all warnings even if you are familiar wit...

Страница 27: ...est probes may be handled only behind the finger protection as otherwise there is a risk of an electric shock when measuring If the multimeter or the test probes are damaged including test lead they m...

Страница 28: ...ged The multimeter may not be exposed to any direct heat sources e g heating or any direct sunlight or artificial light Also avoid contact with dripping water and splashes and corrosive liquids Never...

Страница 29: ...icon appears on the display 1 The battery should be replaced as soon as possible to ensure that the multimeter continues to work properly Remove the holster 2 Remove the two screws on the back of the...

Страница 30: ...nt Connect the black test lead to the COM jack 5 and the red test lead to the V jack 6 Set the range selector switch 4 to the desired range in the DC voltage measuring range V If you do not know the v...

Страница 31: ...e in the DC current measuring range A If you do not know the current first set the highest possible measuring range and then reduce it gradually to the lower ranges until you obtain a satisfactory mea...

Страница 32: ...behind the finger protection to avoid a distorted measurement result For measurements of low resistances 200 range the internal resistance of the test leads can lead to a distorted result To avoid su...

Страница 33: ...tch 4 to the position in the measuring range Connect the red test probe 7 to the anode and the black test probe 7 to the cathode of the diode to be tested The forward voltage is indicated in volts on...

Страница 34: ...nd at the back of the holster 2 to set up the multimeter There is also a slot above the stand to facilitate hanging up the multimeter Cleaning maintenance Maintenance Maintenance work is necessary if...

Страница 35: ...test leads before opening the multimeter Remove the holster 2 Remove the two screws on the back of the multimeter and remove the back panel Replace faulty fuse F1 F 250mA 250V or F2 F 10A 250V with a...

Страница 36: ...posal office or the shop where you bought the device Remember to protect the environment Used batteries should not be disposed of in domestic waste They must be taken to a collection point for old bat...

Страница 37: ...ur hotline support staff will initiate further servicing procedures depending on the fault Within the warranty period the product will be repaired or replaced free of charge as we deem appropriate No...

Страница 38: ......

Отзывы: