Switched Mode Power Supply

 

Operating manual

 

PAP3200HV

 

 

Perämiehenkatu 6, FIN 24100 Salo, Tel. +358 2 777 290, Fax +358 2 777 2918, [email protected], www.powerfinn.fi

 

 

 

Dimensions 

 

Installation

 

The location must be dry, dust-free and indoors. Equipment must be connected to an earthed mains socket outlet. For 
unplugging the unit, make sure the wall socket is near and in an easy access area. The acceptable full power temperature 
range is 0

°C…+40°C. The thermal protection will cause the unit to power down at too high an operating temperature. The 

power supply is not waterproof. Keep it dry and away from areas with high humidity in order to avoid the risk of electrical 
shock and damage to the charger.  

 

 

 

Wall mounting 
The power supply can be mounted to the wall with the two mounting holes on 
both ends of the power supply unit as shown in the figure. 

It is recommended that the power supply is mounted vertically on to the wall. It 
is suitable for mounting on a concrete or other non-combustible surface only. 

Leave at least 10 cm free space at the cooling fan end and at both sides of the 
power supply to ensure sufficient ventilation. 

When used as a charger, the charging process generates explosive hydrogen 
gas.  Install  the  power  supply  as  far  away  from  the  battery  as  possible  to 
prevent  hydrogen  gases  from  entering  the  charger.  Keep  the  area  well 
ventilated. Never use an open flame or equipment that produces sparks close 
to the power supply and battery.

 

 

Charging operation 

1.

 

Ensure  that the  power  supply  is  switched  off  and  that  the  environment  meets  the  conditions  as  described  in 
the previous section. 

2.

 

Connect  the  output  cables  to  the  load  /  battery  terminals:  +  cable  to  the  +  terminal  and 

–  cable  to  the  – 

terminal

 

3.

 

Turn the power on by turning the switch to position 1.

 

4.

 

During normal power supply operation / charging process, the STATUS LED is continuously orange.

 

5.

 

To avoid sparking, turn off the power supply before disconnecting the cables.

 

Содержание PAP3200HV

Страница 1: ...d using nominal output voltage Mechanics Wall mounting see dimensions p 3 Connectors Input Input power cord Output SPT5 2 H 7 5 Phoenix Enclosure Aluminum case IP20 Weight 7 1 kg without cables Output...

Страница 2: ...Cable set PAP3200HV 24AI Analog control by external 0 5Vdc voltage Control signal isolated from power supply input and output 1 5 m modular connector other ends open PAP3200HV 24H Power failure alarm...

Страница 3: ...power supply is mounted vertically on to the wall It is suitable for mounting on a concrete or other non combustible surface only Leave at least 10 cm free space at the cooling fan end and at both si...

Страница 4: ...top cover See the instructions for choosing the programmed voltage and the fine tune adjustment LED s STATUS LED indicates different phases during the charging process In normal power supply operatio...

Страница 5: ...and J69 for optional features Optional relay alarm temp comp Ext ON OFF Ext LED and serial bus connections Screw terminals connector J101 1 Alarm relay common 2 Alarm relay nc 3 Alarm relay no 4 Aux 1...

Страница 6: ...round connection Common is connected to NC when the power is switched off Common is connected to NO when the power is switched on Internal alarm relay Isolation Terminals to case 120Vac Terminals to O...

Страница 7: ...as a potentiometer controlled device It is important to keep in mind that the 5V output may not be loaded more than 20 mA otherwise proper operation cannot be guaranteed Instructions for calibration...

Страница 8: ...er with a slave unit The master unit can be either a trimmer adjustable model e g PAP3200 24 or an analog controllable model e g PAP3200 24AI The slave unit is a separate unit without any adjustment p...

Страница 9: ...Switched Mode Power Supply Operating manual PAP3200HV Per miehenkatu 6 FIN 24100 Salo Tel 358 2 777 290 Fax 358 2 777 2918 info powerfinn fi www powerfinn fi 9...

Страница 10: ...Switched Mode Power Supply Operating manual PAP3200HV Per miehenkatu 6 FIN 24100 Salo Tel 358 2 777 290 Fax 358 2 777 2918 info powerfinn fi www powerfinn fi 10...

Страница 11: ...Switched Mode Power Supply Operating manual PAP3200HV Per miehenkatu 6 FIN 24100 Salo Tel 358 2 777 290 Fax 358 2 777 2918 info powerfinn fi www powerfinn fi 11...

Страница 12: ...Switched Mode Power Supply Operating manual PAP3200HV Per miehenkatu 6 FIN 24100 Salo Tel 358 2 777 290 Fax 358 2 777 2918 info powerfinn fi www powerfinn fi 12...

Отзывы: