Powerfinn PAP3200 Скачать руководство пользователя страница 1

 

Switched Mode Power Supply

 

Operating manual

 

PAP3200

 

 

Perämiehenkatu 6, FIN 24100 Salo, Tel. +358 2 777 290, Fax +358 2 777 2918, [email protected], www.powerfinn.fi

 

 

 

 

 

 

Features: 

Wide output range 0…320Vdc 

Analog control by an external 
0…5Vdc 

Power failure alarm output 

Master-slave connection

 

 

Powerfinn PAP series is a high power, lightweight, advanced power supply using modern switching technology. 
All  units  can  be  used  as  a  power  supply  or  constant  voltage  battery  charger.  The  output  voltage  and  output 
current  can  be  adjusted  from  0  to  maximum  value  by  an  external  0-5V  analog  control,  with  internal  adjustment 
trimmers or from serial bus. 

 

 

Specifications 

Input voltage 

70…264Vac 1–phase ( 70…230Vac, reduced power ) 

 

70…369Vdc  

Efficiency 

89% at full load, >90% at 50% load ( 230Vac input ) 

Input current 

16A ( max) 

Frequency 

47–63Hz 

Power factor 

>0,98 

 
Inrush current 

soft start 

Output ripple 

<1% from output voltage, rms 

Mechanics 

Wall mounting, see dimensions p. 3 

Connectors 

Input 

Input power cord 

 

Output 

Models 12V, 24V, 36V, 48V 

     copper busbar terminals 

 

 

Models 72V, 110V, 160V, 220V      10mm

2

 3m output cables 

Enclosure 

Aluminum case, IP20 

Weight 

 

7,1 kg without cables 

Output Grounding 

Floating 

Ambient temperature range 

-20°C…+40°C at full load, abs. max. +55°C  

Overtemperature protection 

Processor controlled on/off 

Overcurrent protection 

Electrical current limit 

Reverse polarity protection 

With fuse   ( 12VDC version doesn’t have fuse ) 

 
Standards 

Safety 

Class 1 

                                                                        EN60335-2-29:2004 
                                                                        EN60335-1:2002 +A11:2004 +A1:2004 +A12:2006 +A2:2006 
                                                                        EN50366:2003 +A1:2006 

                                                                                Conformity can be limited depending end application, 
                                                                                output control method or unit mechanical structure 

 
 

EMC 

Limits EN55022 Class A or B, 

Application must discuss in detail

 

                                                                

  

                                                                   

 

 

Содержание PAP3200

Страница 1: ...d 90 at 50 load 230Vac input Input current 16A max Frequency 47 63Hz Power factor 0 98 Inrush current soft start Output ripple 1 from output voltage rms Mechanics Wall mounting see dimensions p 3 Conn...

Страница 2: ...Vac Intelligent optional models 24V models as type designation example Model Option description Cable set PAP3200 24AI Analog control by external 0 5Vdc voltage Control signal isolated from power supp...

Страница 3: ...ck and damages to the charger Wall mounting The power supply can be mounted to the wall with the aid of the two mounting holes on both ends of the power supply unit as shown in the figure The power su...

Страница 4: ...ion Both voltage and current can be adjusted from zero to the maximum value Maximum 3200W 3000W output power is available within the adjustment range Temperature compensated models type example PAP320...

Страница 5: ...lay alarm temp comp sense Ext ON OFF Ext LED and serial bus connections Screw terminals connector J101 1 Alarm relay common 2 Alarm relay nc 3 Alarm relay no 4 Aux 12 5V 5 Aux 6 Serial bus out 7 Seria...

Страница 6: ...is connected to NC when the power is switched off Common is connected to NO when the power is switched on Isolation Output to case 500V Output to GND 120V Technical data 1A 24Vdc 0 5A 120Vac Optional...

Страница 7: ...nal potentiometers The 5V can be used as a supply for external circuits The circuit shown to the left lets the power supply operate ass a potentiometer controlled device It is important to keep in min...

Страница 8: ...h has an alarm relay output If more current or a higher voltage is needed the adjustable master power supply can be connected in parallel or in series via the digital bus with the slave unit which fol...

Отзывы: