22
TIP SEAL SET REPLACEMENT
every 5,000 HOURS – MAINTENANCE (High pressure model)
10,000 HOURS – MAINTENANCE (Regular pressure model)
1.
CONFIRMATION OF THE PARTS
i.
Confirm if the Tip Seal you purchased is correct for the air end you are replacing (see below parts listing).
WARNING
Per OSHA regulations, ALL power must be
locked out before performing any maintenance.
CAUTION
This service should be performed by an authorized
Powerex Service Center to avoid failure.
Tip Seal Set
SLAE03E
SLAE05E
SLAE05EHP
92834090
92832070
92832080
Содержание SLAE03E
Страница 1: ...Scroll Compressor Service and Maintenance Manual ...
Страница 4: ...4 INTAKE AIR FILTER REPLACEMENT every 2 500 HOURS MAINTENANCE 1 Remove the Filter Cover ...
Страница 6: ...6 3 Reassemble the Filter Cover ...
Страница 8: ...8 2 Clean FS fins with a blow gun ...
Страница 9: ...9 3 Reassemble the FS cover ...
Страница 10: ...10 BLOWER FAN CLEANING every 5 000 HOURS MAINTENANCE 1 Remove five screws and take the Fan Cover off ...
Страница 11: ...11 2 Blow off dirt and dust ...
Страница 12: ...12 FAN DUCT CLEANING 5 000 HOURS MAINTENANCE Wipe out dirt and dust ...
Страница 17: ...17 v Put the removed Plastic Dust Cap back ...
Страница 18: ...18 2 PIN CRANK BEARINGS i Remove the Fan Duct 2 Remove these three bolts ...
Страница 19: ...19 ii Remove FS Fixed Scroll Set Remove bolts and nuts and remove the FS 5 HP models only 5 HP models only ...
Страница 24: ...24 2 REPLACEMENT i Remove the fan duct 2 Remove these bolts ...
Страница 25: ...25 ii Remove FS Fixed Scroll Set Remove bolts and nuts and remove the FS 5 HP models only 5 HP models only ...
Страница 27: ...27 iv Remove dust from both OS and FS plates with clean cloth or air ...
Страница 30: ...30 vii Insert LP Tip Seal all the way and cut excessive material ...
Страница 31: ...31 viii Repeat the same procedure for FS Tip Seal set ...
Страница 32: ...32 ix Insert new Backup Tube in the FS then insert new Dust Seal on the Backup Tube Backup Tube Dust Seal ...
Страница 34: ...34 PARTS LIST ...