Note the charging capacity is usually higher than the actual capacity 
of the battery owing to some energy lost as heat. Charging capacity 
cannot be used to judge the performance the battery. Instead, it can 
only be used to determine the progress of the charger. It is normal 
for this number to exceed the actual capacity by as much as 20-
30%.  

 

Q: I see that the charging capacity is much higher than the capacity I 
programmed. Why doesn’t the charger terminate correctly?  

 
A: The charger terminates by voltage and by temperature 
simultaneously. For certain older (and low quality) batteries, they do 
not produce the proper end-of-charge signal (a small voltage drop at 
the conclusion of the charge) needed for the charger to stop. At the 
same time, the battery temperature failed to reach the termination 
limit as the charging rate was probably too low. 
 
To address this issue, you should attempt to perform a BREAK-IN 
mode on the batteries first. You should also use a higher charging 
rate.  

 

Q: Using the BREAK-IN mode, I am seeing a charging capacity 
much higher than the capacity I programmed.   

 
A: When using the BREAK-IN mode, the charger puts in 1.6 times 
the capacity of the battery (entered at the start of the charge). This 
does not cause any harm to the battery as the charging rate is very 
low (only 10% of the battery capacity). The increased total charging 
capacity compensates for energy lost as heat.  

 

 

Time

 

:  

This is the number followed by the unit “

MIN

.” This is the time 

elapsed for the particular routine such as charging, discharging or 
rest in the program.  

 

 

 

 

 

Voltage: 

This is the number followed by the unit “

VOLT

.” It represents the 

battery voltage. If you compare this with a voltmeter while charging, 
the values will not match as a voltmeter is unable to measure the 
battery voltage during charging or discharging.  

 

 

 

 

At any given time during the program, the charger will either be 
charging, discharging or resting. The LCD displays the action in 
black boxes containing 

CHARGE

DISCHG

, or 

REST

 

 
 

8. 

If CYCLE mode is selected, it is also possible to review the battery 
capacity of the completed cycle after the first cycle finishes.  

 

Press the 

UP

 or 

DOWN

 key while the active slot is in the cycle mode 

will display the discharge capacity for that cycle. The LCD will also 
display “

CYCLE HISTORY

.”  

 

 
 

9. 

When the program for a slot is completed, 

DONE

 will displayed to 

the right of the bank number. With the exception of DISCHARGE 
mode, topoff charge and trickle charge (continuous) will be applied.  
 
For CHARGE mode, the total charged capacity will be displayed.  
 
For REFRESH & ANALYZE, BREAK-IN, DISCHARGE mode, the 
total discharge capacity will be displayed. “AVAILABLE CAPACITY” 
icon will also be shown.  
 
For CYCLE mode, the discharge capacity of the final cycle is 
displayed. “CYCLE HISTORY” icon will also be shown. Use the 

UP

 

and 

DOWN

 key to access discharge capacity for all the cycles 

performed.  
 
The capacity information will be stored as long as the battery is 
inserted in the charger. It will be lost upon removal of the battery. 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Warning!  
Batteries should be disposed of seperately from 
the municipal waste stream via designated 
collection facilities appointed by the government 
or the local authorities.  
 
For more detailed information about the disposal 
of batteries, please contact your city office, waste 
disposal service or the shop where you 
purchased the product. 

 

 
 
 
 
 

Manufactured By: 

MAHA ENERGY CORP.  

1647 Yeager Ave. La Verne, CA 91750 USA 
Tel: 1-800-376-9992, 1-909-392-1568

 

http://www.mahapowerex.eu/

 

Copyrighted ® 1993-2007 Maha Energy Corp.

 

Содержание MH-C9000

Страница 1: ...rge Termination Voltage 0 90V Discharging Current Programmable from 0 1A to 1 0A in increments of 0 1A Capacity Storage Memory 12 Cycle mode only Supported Capacity 100 to 20 000mAh Charger Input Power 12V 2 0A Adapter Input 100 240V 50 60Hz Always ensure that the batteries can accept the programmed rates GENERAL BATTERY EDUCATION What is 0 1C 0 2C etc C stands for the battery capacity and the num...

Страница 2: ...ed frequently at least once every two weeks Charge Batteries in storage for more than two weeks but less than 3 month Refresh Analyze Batteries in storage for more than 3 month Break In Battery Rescue Steps For batteries that do not perform favorably after using the mode recommended above the following sequence can be applied 1 Refresh Analyze for one to three times 2 If capacity is still low use ...

Страница 3: ...tion 6 To ensure safety the charger performs a battery health impedance check at the beginning of the program If the battery fails this test HIGH would be displayed and program will be terminated Typically alkaline and extremely aged battery will fail this test For a rechargeable battery it is recommended for the battery to be discarded NOTE This test is not performed for the discharge mode If thi...

Страница 4: ...tage If you compare this with a voltmeter while charging the values will not match as a voltmeter is unable to measure the battery voltage during charging or discharging At any given time during the program the charger will either be charging discharging or resting The LCD displays the action in black boxes containing CHARGE DISCHG or REST 8 If CYCLE mode is selected it is also possible to review ...

Отзывы: