2

Climate Control Duplex

Basic Alternator Package

All Powerex duplex air compressors may be ordered with a 
simplified line voltage basic alternator package. The basic 
alternator package consists of an alternating coil and two 
magnetic motor starters. Motor starters are selected and 
wired for intended input voltage and  are furnished with 
properly sized overload heaters.

Automatic Tank Drain

Powerex air compressors may be ordered with a manual 
or electric type automatic tank drain. A manual drain 
attachment is furnished with each unit.

Vibration Dampening Pads

Waffle type design vibration pads are provided as standard 
equipment.

Operation

Factory calibrated DPST pressure switches provide lead and lag 
settings. When using an alternator-starter package, the lead 
switch energizes the alternator and the alternator activates 
the compressor that was on standby during the previous cycle. 
If the demand exceeds the capacity of one compressor, the lag 
switch will cause both compressors to run simultaneously. Upon 
failure of either compressor, the lag switch will continue to 
activate the workable compressor.
Single-phase motors (3/4 HP & 1 HP) have built-in overload 
protection with manual reset. Three-phase motors require 
a magnetic starter and three overload heaters. Heaters are 
included with three-phase compressors that have a factory 
mounted alternator.

NOTE:

 All pump models operate turning clockwise opposite 

the motor shaft / pump flywheel / belt guard side of the unit. 
Improper rotation will cause oil to spray out of the breather 
vent opening.

Safety Guidelines

This manual contains information that is very important 
to know and understand. This information is provided for 
SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help 
recognize this information, observe the following symbols.

 

Danger indicates an imminently  

  hazardous situation which, if 

not avoided, WILL result in death or serious injury.
 

Warning indicates a potentially  

  hazardous situation which, if 

not avoided, COULD result in death or serious injury.
 

Caution indicates a potentially 

  minor or moderate injury.

 

Notice indicates important  

  information, that if not 

followed, may cause damage to equipment.

NOTE:

 Information that requires special attention.

CAlifOrNiA PrOPOSiTiON 65

 

This product or its power cord  

  may contain chemicals known 

to the State of California to cause cancer and birth defects or 
other reproductive harm. Wash hands after handling.

installation

MOuNTED AND CONNECTED OPTiONS
Deluxe Alternator Package

All Powerex Duplex air compressors may be ordered with 
an optional deluxe alternator package consisting of two 
magnetic motor starts with thermal overloads, an alternating 
coil, a 120 VAC control transformer and a three-position 
selector switch. The three-position switch allows for 
automatic alternation or only running one unit at a time. This 
will allow for service on one unit while other unit is running.

Performance Specifications

Base Model

Motor rating

Compressor rPM

Compressor Capacity ACfM @ 80 psig

HP

rPM

100% runtime

50% runtime

33% runtime

AD-107

0.75

1725

980

2.1

1.07

0.71

AD-007

0.75

1725

980

2.1

1.07

0.71

AD-110

1.0

1725

1120

3.5

1.74

1.15

AD-010

1.0

1750

1120

3.5

1.74

1.15

AD-015

1.5

1760

860

4.6

2.3

1.5

AD-020

2.0

1755 

1250

6.9

3.4

2.3

AD-030

3.0

1725

1050

10.3

5.2

3.4

AD-050

5.0

1750

1150

19.0

9.5

6.3

AD-075

7.5

1750

950

28.6

14.3

9.5

AD-100

10.0

1765

880

37.8

18.9

12.5

NOTE:

 0.75 HP pumps must be used under altitudes of 5000 feet.

Above 5000 feet, 1 HP pumps must be used.

Содержание ad series

Страница 1: ... break in and are tested for air delivery leakage and power consumption Tank mounted units are shipped with a proper fill of compressor oil in the crankcase and are furnished with an intake filter with a replaceable cartridge This filter is designed to remove contaminates in the inlet air as well as provide a quiet operation All models have conveniently located oil drain and filler ports to facili...

Страница 2: ...derstand This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help recognize this information observe the following symbols Danger indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentia...

Страница 3: ...il DTE heavy oils Dispose of oil in accordance with state or local codes Lead Switch Cut In 70 psig 490 kPa Cut Out 90 psig 630 kPa Lag Switch Cut In 60 psig 420 kPa Cut Out 80 psig 560 kPa L1 L2 L3 IT 1 IT 2 IT 3 A1 A2 1M Motor 1 Motor 2 2M Selector Switch L1 L2 L3 A1 A2 2T 1 2T 2 2T 3 X1 X2 FU FU FU Alt Figure 3 Basic Alternator package wiring diagram for three phase units L1 Lag Switch Cut In 6...

Страница 4: ...5 00 20 00 43 30 40 00 18 00 14 60 69 80 462 442 AD 015 1XX 41 50 25 80 17 75 38 75 18 00 15 75 12 25 57 10 322 302 AD 015 3XX 63 75 25 00 20 00 43 30 40 00 18 00 14 60 69 80 487 467 AD 020 3XX 63 75 26 00 20 00 43 60 40 00 18 00 14 60 80 60 512 492 AD 030 3XX 64 10 25 4 20 00 43 70 40 00 18 00 14 60 80 25 715 695 AD 030 4XX 70 75 28 10 24 00 48 20 42 00 18 00 16 80 81 75 845 825 AD 050 4XX 71 60 ...

Страница 5: ...hs Pressure gauge Inspect l Every 2500 hours or less l Inspect s Replace NOTES 1 Inspect and perform maintenance periodically according to maintenance schedule 2 The maintenance schedule relates to the normal operating conditions If the circumstances and load condition are adverse shorten the cycle time and do maintenance accordingly 3 The tension of the V belt should be adjusted during initial st...

Страница 6: ...trol rings cylinder gasket and sealant Motor HP 3 4 1 2 4 8 A 010 6004AP 1 1 2 2 2 4 8 A 010 6004AP 3 4 5 5 A 030 6004AP 5 4 10 A 050 6004AP 7 1 2 4 10 A 075 6004AP 10 6 10 A 075 6004AP D Intake Filter Element Motor HP 3 4 1 2 0 1 A 010 6023AP 1 1 2 2 2 0 2 A 010 6023NP 3 4 0 2 A 010 6023NP 5 4 0 2 A 010 6023NP 7 1 2 4 0 2 A 010 6023NP 10 4 0 2 A 010 6023NP E In Tank Check Valve Motor HP Size 3 4 ...

Страница 7: ...P J Pressure Electric Switches For all models Lead Switch Set at approximately 70 psig 490 kPa cut in and 90 psig 630 kPa cut out 1 0 9 A 100 6010 Lag Switch Set at approximately 60 psig 420 kPa cut in and 80 psig 560kPa cut out 1 0 9 A 100 6011 K Tank Motor HP Tank Size 3 4 Through 1 1 2 30 gallon 1 134 0 A 015 6030AP 3 4 Through 1 1 2 80 gallon 1 235 0 A 015 6080AP 2 3 80 gallon 1 243 0 A 030 60...

Страница 8: ...ctions iii that have been materially modified without the prior written approval of Powerex or iv that experience failures resulting from operation either intentional or otherwise in excess of rated capacities or in an otherwise improper manner f The warranty provided herein shall not apply to i any defects arising from corrosion abrasion use of insoluble lubricants or negligent attendance to or f...

Отзывы: