Thank  you  for  selecting  this  uninterruptible  power  system  (UPS).  It  provides  you  with  a  perfect 
protection for connected equipment. The manual is a guide to install and use the UPS. It includes 
important safety instructions for operation and correct installation of the UPS. If you should have 
any problems with the UPS, please refer to this manual before calling customer service. 

Please save or recycle the packaging materials 

The  UPS‘s  shipping  materials  are  designed  with  great  care  to  provide  protection  within  delivery. 
These materials are invaluable if you ever have to return the UPS for service. Damage happened 
during transit is not covered under the warranty. 

1.

 

Introduction 

The UPS is a line interactive uninterruptible power system (UPS). When utility input is normal, 

the  UPS  would  provide  surge  protection  and  energy  to  charge  the  internal  battery.  If  the  utility 
input is abnormal, the UPS can supply AC power to the loads immediately. 
(1)

 

Utilizes microprocessor based controls, it will minimizes the dependency on hardware. Beside 
this, it maximizes system flexibility and optimizes the assurance of reliability. 

(2)

 

Automatic frequency selection to match with utility power. 

(3)

 

High-grade battery charger to prolong battery’s life and fully charge the battery. 

(4)

 

With actual overload protection both in line and battery mode. 

2.

 

System Description 

Intelligent microprocessor control 

The product is an advanced line-interactive UPS based on microprocessor control. This means that 
it operates with the newest technology, high performance and powerful function. 
The  line-interactive  UPS  is  an  intelligent  protector  and  provides  pure,  reliable  AC  power  to  the 

critical loads - protecting them from utility power blackout, swells, sags, surges and interference. 
The loads could include sensitively medical instruments, computers, telecommunication systems, 
and industrially automatic equipment. Under power normal condition, the line-interactive design 
enables the system to adjust and filter power fluctuations continuously and automatically.    In the 
event of power failure, it can provide immediately back-up power from the batteries without any 
interruption. Complete transference will be achieved within 4m seconds, with no interruption.   
Beside  this,  when  the  utility  power  is  connected,  the  charger  would  work  automatically  even 
under  power  switch  is  OFF.  Furthermore,  in  order  to  save  the  battery  energy,  UPS  can  be  set  to 
turn it off under backup mode if none of the connected loads is operating. 

Advanced battery management 

The visual and audible indications of the UPS present the battery’s status including capacity degree 
and battery condition. Self-test function let UPS detect a weak battery before it is put into service. 
The UPS normally perform a self-test at power up and manual self-test condition. Self-test function 
can be conducted manually with the ON/TEST switch at any time. 

Advanced monitoring software 

The  line-interactive  UPS  and  UPSMON  series  monitoring  software  (optional  kits)  make  your 
computer operate intelligent and provide you with the ability of perfect protection of your critical 

devices.  The  software  is  available  for  most  operation  systems  and  is  supplied  with  a 

communication cable that connects to the UPS. 

 

 

Содержание 1025VA

Страница 1: ...U P S Line Interactive Simulated Sine Wave 1025VA 3000VA USER S MANUAL...

Страница 2: ...S to Computer with USB RS232 port 6 6 Operations 7 6 1 Switch on with Green Mode Function 7 6 2 Switch on with Disabled Green Mode Function 7 6 3 Switch off UPS 7 6 4 Silence Function 7 6 5 Self test...

Страница 3: ...n essential before connection supply CAUTION Do not dispose of batteries to fire the battery may explode CAUTION Do not open or mutilate the battery released electrolyte is harmful to human skin eyes...

Страница 4: ...oprocessor control This means that it operates with the newest technology high performance and powerful function The line interactive UPS is an intelligent protector and provides pure reliable AC powe...

Страница 5: ...of 15 C to 25 C Only a technician from the manufacturer or an authorized agent may service the unit Do not open UPS cabinet as the components may contain high voltage and may be fatal The output rece...

Страница 6: ...P mode indicator Yellow The indicator illuminates when the power is supplied from the battery AVR BUCK mode indicator Yellow The indicator illuminates when the UPS buck the input power to associate th...

Страница 7: ...e connected loads exceed the protected receptacle s capacity UPS SURGE PROTECTED OUTLETS When utility power is normal the UPS outlets are powered by utility power with AVR function Any higher or lower...

Страница 8: ...witch off UPS Press the OFF button at LINE or BACKUP modes and keep pressing more than 3 second to turn off the UPS ATTENTION UPS can automatically charge itself under OFF mode Advanced Battery Manage...

Страница 9: ...teries ELECTRIC ENERGY HAZARD Do not attempt to rewire alter or change any battery wiring or connectors Attempting to make such alterations can cause injury 8 Trouble Shooting 8 1 BACKUP slow alarm Wh...

Страница 10: ...n to the input utility power Check the connection between UPS input outlet and utility power Fuse melted or circuit breaker tripped Replace fuse or reset circuit breaker you can find a spare fuse for...

Страница 11: ...2V 9Ah Quantity 2 2 3 Typical Recharge Time 6 8 hr to 90 Management Communication Indicator LED Control Panel IMP model LCD Control Panel IMD model Communication Port USB B type AP model Physical Dime...