background image

PowerBoss 5,500 Watt Storm-Plus Generator

3

• When using generator for backup power, notify utility

company. Use approved transfer equipment to isolate
generator from electric utility.

• National Electric Code requires generator to be properly

grounded to an approved earth ground. Call an electrician for
local grounding requirements.

• Use a ground circuit fault interrupter (GFCI) in any damp or

highly conductive area, such as metal decking or steel work.

• Do not touch bare wires or receptacles.

• Do not use generator with electrical cords which are worn,

frayed, bare or otherwise damaged.

• Do not operate generator in the rain.

• Do not handle generator or electrical cords while standing in

water, while barefoot, or while hands or feet are wet.

• Do not allow unqualified persons or children to operate or

service generator.

Generator produces powerful voltage.
Failure to properly ground generator can result
in electrocution.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.

WARNING

• Do not allow any open flame, spark, heat, or lit cigarette

during and for several minutes after charging a battery.

• Wear protective goggles, rubber apron, and rubber gloves.

Storage batteries give off explosive hydrogen gas
during recharging.
Hydrogen gas stays around battery for a long
time after battery has been charged.
Slightest spark will ignite hydrogen and cause
explosion.
You can be blinded or severely injured.
Battery electrolyte fluid contains acid and is
extremely caustic.
Contact with battery fluid will cause severe
chemical burns.

DANGER

• Do not touch hot surfaces.

• Allow equipment to cool before touching.

Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.

WARNING

• Do not tamper with governed speed. Generator supplies

correct rated frequency and voltage when running at governed
speed.

• Do not modify generator in any way.

Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.

CAUTION

• See “Don’t Overload Your Generator” on page 9.

• Start generator and let engine stabilize before connecting

electrical loads.

• Connect electrical loads in OFF position, then turn ON for

operation.

• Turn electrical loads OFF and disconnect from generator

before stopping generator.

Exceeding generators wattage/amperage cappacity can
damage generator and/or electrical devices connected
to it.

CAUTION

• Use generator only for intended uses.

• If you have questions about intended use, ask dealer or call

the Generac generator helpline at 1-800-270-1408.

• Operate generator only on level surfaces.

• Do not expose generator to excessive moisture, dust, dirt, or

corrosive vapors.

• Do not insert any objects through cooling slots.

• If connected devices overheat, turn them off and disconnect

them from generator.

• Shut off generator if:

-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.

Improper treatment of generator can damage it and
shorten its life.

CAUTION

Содержание 5500 Storm-Plus

Страница 1: ...zards Obey all safety messages that follow this symbol to avoid possible injury or death Questions Help is just a moment away Call Generac Generator Helpline 1 800 270 1408 M F 8 5 CT Web www generac...

Страница 2: ...ath or serious injury CAUTION indicates a hazard which if not avoided might result in minor or moderate injury CAUTION when used without the alert symbol indicates a situation that could result in equ...

Страница 3: ...can be blinded or severely injured Battery electrolyte fluid contains acid and is extremely caustic Contact with battery fluid will cause severe chemical burns DANGER Do not touch hot surfaces Allow...

Страница 4: ...lectrical overload Fuel Tank Capacity of five 5 U S gallons Grounding Wing Nut Used for proper grounding of unit see page 3 Oil Fill Add engine oil here Recoil starter Used to start the engine Rocker...

Страница 5: ...rton down flat Remove all packing material carton fillers etc Remove the generator from the shipping carton CARTON CONTENTS Check all contents If any parts are missing or damaged call the generator he...

Страница 6: ...ricated and sealed ball bearing that requires no additional lubrication for the life of the bearing Add Gasoline WARNING Never fill fuel tank indoors Never fill fuel tank when engine is running or hot...

Страница 7: ...ften builds up in ungrounded devices OPERATING THE GENERATOR CAUTION Never start or stop the engine with electrical loads connected to the receptacles AND with the connected devices turned ON Starting...

Страница 8: ...to run a 120 Volt load This receptacle powers 120 240 Volt AC 60 Hz single phase loads requiring up to 5 500 watts of power 5 5 kW at 30 Amps for 120 Volts or 240 Volts The outlet is protected by a p...

Страница 9: ...e generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each...

Страница 10: ...se skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Gene...

Страница 11: ...the Generator Check that cooling air slots and openings on generator are open and unobstructed CAUTION Storage covers can be flammable Do Not place a storage cover over a hot generator Let the unit c...

Страница 12: ...lug wire not connected to spark plug 8 Bad spark plug 9 Water in gasoline 10 Overchoking 11 Excessively rich fuel mixture 12 Intake valve stuck open or closed 13 Engine has lost compression 1 Set swit...

Страница 13: ...PowerBoss 5 500 Watt Storm Plus Generator 13 NOTES...

Страница 14: ...14 PowerBoss 5 500 Watt Storm Plus Generator SCHEMATIC...

Страница 15: ...PowerBoss 5 500 Watt Storm Plus Generator 15 WIRING DIAGRAM...

Страница 16: ...16 PowerBoss 5 500 Watt Storm Plus Generator EXPLODED VIEW MAIN UNIT...

Страница 17: ...Holder 33 66849GS 2 TAPTITE M5 0 8 x 16 34 B4871GS 1 COVER Bearing Carrier 35 23762GS 2 WASHER 10 Ext Shakeproof 36 86494GS 1 SCREW M6 1 0 x 16 Wing Item Part Qty Description 37 B2153GS 4 SCREW 10 Sel...

Страница 18: ...KIT Item Part Qty Description 1 B4217GS 1 ASSEMBLY Handle 2 B1764GS 1 LEG Mounting 3 52858GS 4 NUT Locking Hex M8 1 25 4 39287GS 2 HHCS M8 1 25 x 45 5 93693HGS 1 AXLE 6 B4966GS 2 WHEEL 10 Diameter 7...

Страница 19: ...G Hinge Pin 5 189166GS 2 PIN Hinge Cover Compact 6 68759GS 2 OUTLET 120V 20Amp Duplex 7 189165GS 4 NUT Palnut Pushnut 5 32 8 84198GS 2 CAP Circuit Breaker 9 75207GS 2 CIRCUIT BREAKER 10 43437GS 1 OUTL...

Страница 20: ...iesgo el cual si no se evita puede causar heridas menores o moderadas PRECAUCI N cuando se usa sin el s mbolo de alerta indica una situaci n que podr a resultar en el da o del equipo Siga los mensajes...

Страница 21: ...uedar ciego o sufrir heridas muy graves El fluido de electrolito de la bater a contiene cido y es extremadamente c ustico El contacto con el fluido de la bater a puede causar quemaduras qu micas sever...

Страница 22: ...el motor y est equipado con una pantalla apagachispas Tanque del Combustible El tanque tiene una capacidad de 5 galones americanos de gasolina sin contenido de plomo Tomacorriente Dobles de 120 Voltio...

Страница 23: ...alguna de las partes no est presente o est da ada por favor llame a la linea de ayuda para generadores al 1 800 270 1408 La unidad principal Manual del propietario Aceite para motor Tapones de fijaci...

Страница 24: ...e el tanque del combustible cuando el motor est en funcionamiento o caliente No encienda cigarrillos o fume cuando est llenando el tanque del combustible ADVERTENCIA No llene excesivamente el tanque d...

Страница 25: ...EL GENERADOR PRECAUCI N Nunca encienda o pare el motor con las cargas el ctricas conectadas a los recept culosY con los aparatos conectados ENCENDIDOS Encienda el Motor Desconecte todas las cargas el...

Страница 26: ...Voltios Este recept culo le provee poder a cargas de 120 240 Voltios AC de 60 Hz fase sencilla que requieren hasta 5 500 vatios de energ a 5 5 kW a 30 Amps para 120 Voltios o 240 Voltios La salida es...

Страница 27: ...nte y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que...

Страница 28: ...iar el generador El agua podr a introducirse en el sistema de combustible del motor y causar problemas Adem s si el agua se introduce al generador a trav s de las ranuras para aire de enfriamiento alg...

Страница 29: ...29 PowerBoss 5 500 Watt Storm Plus Generador NOTAS...

Страница 30: ...a en la gasolina 9 Sobrecebado 10 Mezcla de combustible excesivamente rica 11 La v lvula de corte de combustible 12 La v lvula de entrada est atascada est cerrada 13 El motor ha perdido compresi n 1 C...

Страница 31: ...ido autorizada o a cualquier tipo de alteraci n el mal uso negligencia accidentes sobrecarga velocidad excesiva mantenimiento inadecuado reparaci n o almacenamiento que seg n la opini n de los Product...

Страница 32: ...en subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in Generac Portable Products judgme...

Отзывы: