4. DUAL LINK AMP TO AMP BRIDGED CONNECTION
Bridging two amplifiers ( of same model) can be done via the BRIDGED switch and wiring the two amplifiers
as follows:
Fig.13 Dual Link minimum 2 ohm load
SPEAKER
FUSE
POWER
LINE
OUT
LINE
IN
LEVEL
PHASE
MIN
MAX
POWER
STATUS
R
L
LPF
50Hz
150Hz
SUB
SONIC
15Hz
50Hz
BASS
BOOST
0
+18dB
0
180
BRIDGED
BRIDGED
CONNECTION
REMOTE
MASTER
SLAVE
BATT
+
REM
GND
SPEAKER
FUSE
POWER
BATT
+
REM
GND
LINE
OUT
LINE
IN
LEVEL
PHASE
MIN
MAX
POWER
STATUS
R
L
LPF
50Hz
150Hz
SUB
SONIC
15Hz
50Hz
BASS
BOOST
0
+18dB
0
180
BRIDGED
BRIDGED
CONNECTION
REMOTE
MASTER
SLAVE
HEAD UNIT
MASTER AMP SIDE PANEL
SLAVE AMP SIDE PANEL
MASTER AMP SIDE PANEL
SLAVE AMP SIDE PANEL
2 – 4 ohm
SUBWOOFER
SWITCH POSITION
BRIDGED
MASTER
SLAVE
SWITCH POSITION
BRIDGED
MASTER
SLAVE
RJ45 Cable
NOTE: SPEAKER CONNECTION FOR BRIDGING TWO AMPS
•
The mono woofer must be connected between the speaker (+) terminals of the two amplifiers and use
at least #12 gauge speaker wiring.
•
Install a #12 gauge wire link between the speaker (–) terminals of the two amplifiers. If this is not done,
the system will not function properly, and damage to the amplifiers may result.
•
Total impedance of speakers must be over 2-ohms. If the impedance drops under 2-ohms, critical dam-
age to the amplifier will occur.