FUEL SYSTEM 

 

 

The diesel fuel system for the generator set must be designed to operate independently from the vehicles 

main engine if both engines are to be operated at the same time. The best way to do this is to have separate fuel 
tanks, but this is usually impractical because of space restrictions. In most installations both engines operate 
from a common fuel tank with separate pick-up tubes for each engine, not a Tee fitting arrangement. This 
prevents either or both engines from being starved for fuel. The generator set fuel pick-up tube is generally 
shorter than the vehicles; therefore fuel may not be available to the generator when fuel supply is low. This will 
prevent the generator from depleting the fuel supply needed by the main engine. 

 
NOTE: 

Using a simple Tee fitting to supply both engines from a common fuel line is not recommended. This 

practice may possible cause a fuel starvation situation to either or both engines. Also, if excessive pressure were 
to build up in the main supply line it could possible cause a failure of the generators fuel lines or connectors and 
a hazardous fuel leak may occur. 
 
 

Care must be taken when routing the fuel line from the main tank to the generator set. Keep the fuel line 

as short as possible while maintaining adequate clearance from the exhaust system. Fuel lines must be run along  
the frame side rails or coach under carriage. Never run fuel lines inside of the coach.  Securely fasten the fuel 
lines with hardware that is recommended for the type of fuel line used. The fuel lines should enter the generator 
compartment at a point nearest to the generators fuel line connection fittings. Allow for a minimum of 8inches 
of flexible fuel line to make the connection. Use proper size fuel line to accommodate the fuel flow needed. 
Steel fuel line or high quality fuel hose is recommended, either one should have a minimum of ¼” ID and 
strong enough to withstand road and climatic conditions. 
 
 
 

EXHAUST SYSTEM 

 

Exhaust system components will vary from one installation to another; therefore a muffler and tailpipe 

may not always be furnished with the Genset. However, it is imperative to install a muffler and tailpipe to 
reduce exhaust noise and direct exhaust gases beyond the vehicles perimeter and away from the normal head-on 
air stream. Install a tail pipe with as few bends as possible to prevent excessive backpressure. A properly 
installed exhaust system must be vapor tight, quiet and completely safe for the vehicle, its occupants and 
surroundings. Installation of an approved Spark Arrestor is required. 
 

 
The exhaust system components must be approved and properly installed to meet the codes and 

regulations required by Federal and State agencies. Exhaust Mufflers and Spark Arrestors supplied by Power 
Technology meet code and standard requirements set forth by the USDA Forest Service.  
 

 
Laws pertaining to application and maintenance of a Spark Arrestor may vary depending on your 

location and State regulations. Federal laws apply on Federal lands. If a generator is used in a forest, on brush or 
grass covered unimproved land it must be equipped with a Spark Arrestor. It is the responsibility of the vehicle 
owner or operator to install and maintain the entire exhaust system in good working condition. 
 

CAUTION: 

Any person (s) who installs an unapproved Muffler, Spark Arrestor or other exhaust system 

component, and/or modifies an exhaust system or component that may result in a hazardous condition is liable 
for damages, injuries or warranty expense caused by such unapproved installation and/or modification. 

 

10

 

Содержание PT-10000

Страница 1: ...PT 8000 PT 10000 PT 12000 Operators Manual Power Technology Southeast Inc 634 State Road 44 Leesburg FL 34748 8103 352 365 2777 Fax 352 787 5545 3 2013 MANPT8 12 SINGLE OR THREE PHASE...

Страница 2: ...your Kubota engine or for the number of your local Kubota dealer TO OUR CUSTOMERS Thank you for your purchase of a Power Technology Generator The information contained in this manual applies to PT 8 1...

Страница 3: ...Loss of revenue or the rental of equipment due to down time N Generator repairs made within the warranty period other than by an authorized Power Tech service dealer without prior written approval fro...

Страница 4: ...RATION 1 2 8 10 12 KW EXCITER TYPE GENERATOR ASSEMBLY 3 GENERATOR END TROUBLESHOOTING GUIDES 4 6 WIRING SCHEMATICS 7 10 SECTION 4 INSTALLATION SAFETY PRECAUTIONS 1 2 GENERATOR INSTALLATION in RECREATI...

Страница 5: ...e industry s Safety Alert Symbol is used throughout this manual and on labels attached the machine itself It warns of the potential for personal injury It is essential that you carefully read the inst...

Страница 6: ...ODIFICATIONS to the engine may impair the function and or safety and affect engine life WEAR SAFETY CLOTHING DO NOT wear loose torn or bulky clothing around machinery Entanglement in rotating parts co...

Страница 7: ...ine exhaust fumes can be very harmful if allowed to accumulate Be sure to run the engine in a well ventilated area where there are no people or livestock near by The exhaust gas from the muffler is ve...

Страница 8: ...he radiator cap while the engine is running or immediately after stopping Wait approximately ten minutes for the radiator to cool before removing the cap Be sure the radiator drain valve petcock and h...

Страница 9: ...hat is only supported by a lift jack or hoist Detach the battery from the engine before conducting service Put a DO NOT OPERATE tag in the key switch to avoid accidental starting To avoid sparks from...

Страница 10: ...ULE 4 ENGINE OIL MAINTENANCE 5 Checking Engine Oil Level Lubricating Oil Specifications Engine Refill Capacities Lubricating Oil Viscosity Recommendations ENGINE COOLANT MAINTENANCE 6 Coolant Recommen...

Страница 11: ...to the engine when operating To prevent a fire hazard keep foreign materials fuel and oil away from the battery wiring muffler and engine Check and clear them daily Be aware of the muffler and exhaus...

Страница 12: ...or 8 seconds per attempt 9 To shut down the engine under normal operations hold the Start Stop Switch for 1 second and release 10 If a fault occurs turn Generator Main Switch OFF and then ON to reset...

Страница 13: ...Output 13 6HP 1800 rpm 17 9HP 1800 rpm Cubic Capacity 68 53 in 1 123 L 91 41in 1 498L Bore and Stroke 3 07 x 3 09 78 0 x 78 4mm 3 07 x 3 09 78 0 x 78 4mm Cylinder Arrangement 3 In Line 4 In Line Firi...

Страница 14: ...acement X Or Once a Year Damaged Worn Or Loose Belts X Or Every Two Years Replace Fuel Hoses X Or Every Two Years Check Radiator Hoses Clamps X Once a Year Abnormal Engine Noise X Abnormal Generator N...

Страница 15: ...lter systems will require additional oil KUBOTA ENGINE REFILL CAPACITIES D1105 EBG1 Crankcase Oil Sump 5 38Qts 5 1L and Filter V1505 EBG1 6 34Qts 6 0L LUBRICATING OIL VISCOSITY RECOMMENDATIONS The min...

Страница 16: ...Power Technology recommends a 1 1 mixture of water glycol NOTE Use a mixture that will provide protection against the lowest ambient temperature NOTE 100 percent pure glycol will freeze at a temperatu...

Страница 17: ...LOG IS PROVIDED TO HELP YOU KEEP AN ACCUMULATIVE RECORD OF OPERATION HOURS ON YOUR GENERATOR SET AND THE DATES REQUIRED SERVICES WERE PERFORMED ENTER TIME TO THE NEAREST HOUR OPERATING HOURS SERVICE R...

Страница 18: ...ssure Switch with Jumper Wire 2 pole Check Power to Hold Circuit of Run Solenoid Check Oil Pressure With Gauge Replace Oil Pressure Switch Defective Solenoid REPLACE Plug Remote Back IN Remote OK Prob...

Страница 19: ...vel Replace Fuel Filter Air IN Fuel System Check Fuel PUMP Excessive Oil Level Dirty Air Filter Engine Overheated Engine Over Loaded Clogged Muffler Over Fueling Injector HIGH ALTITUDE Engine Cold Inc...

Страница 20: ...wer While Cranking Defective Solenoid No Power From Starter Terminal Check Fuel Supply Check Fuel Pump Air IN Fuel System Check Glow Plugs Check Glow Plug Relay Main Switch Battery Dead Turn Switch ON...

Страница 21: ...ING GUIDES 5 7 Zero or Low Voltage Voltage Test 12 Volt Battery Test Overload Condition WIRING SCHEMATICS 8 15 120 Volt Connection C Series Exciter Type 120 240 Volt Connection C Series Exciter Type 1...

Страница 22: ...tage regulator An additional voltage adjustment range is provided if desired by turning the Voltage Adjust Rheostat ELECTRONIC VOLTAGE REGULATION Electronic Voltage Regulator EVR also referred to as a...

Страница 23: ...ogether to form a single laminated assembly The field windings are wound around this assembly FIELD COIL Field coils of heavily insulated wire are wet wound directly onto the poles Field coil leads ar...

Страница 24: ...6206 7 DIODE PLATE 02PLD8CD 02PLD8CD 02PLD8CD 8 EXCITER ROTOR 02RTR8EXC 02RTR10EXCR 02RTR12EXCR 9 MAIN ROTOR 02RTRMN8EXC 02RTR10E 02RTR12E 10 END BELL ASSEMBLY 02EB8 02EB10 02EB12 11 MAIN ROTOR ASSEMB...

Страница 25: ...a one piece unit The Stator cannot be separated from the Generator s outer housing 8 10 12KW C or M BRUSH TYPE GENERATOR ASSEMBLY DESCRIPTION 1 COVER SCREEN 2 BEARING PLATE 3 STATOR ASSEMBLY 4 ROTOR B...

Страница 26: ...120V L L See Note 2 8 AVR 7 AVR T1 T4 L1 T3 L2 T2 T3 T2 T1 L3 L2 L1 8 AVR 7 AVR 6 AVR N T10 T11 T12 Low Parallel Wye 3P4W Approx 190V to 240V L L 110V to 139V L N T4 T5 T6 T9 T8 T7 T4 T5 N Low Zig Za...

Страница 27: ...W VOLTAGE Check Gen Fuse Check Main Breaker is ON Replace Fuse Turn ON Breaker Main Coil Output to Breaker OK BAD Check Ohm s on Exciter Leads 12 V Battery Test Replace Exciter Wiring To Panel Defecti...

Страница 28: ...One Voltage Line may be Higher than the other Check AMP Draw From equipment Check Main Breaker On GenSet Check Gen End 12 VOLT BATTERY TEST One Coil Low Voltage Both Coils Low Voltage Sensing Voltage...

Страница 29: ...K 7 OVERLOAD CONDITION Disconnect AVR Engine Problem Check Stator Coil Resistance See Engine Troubleshooting Replace Stator Replace AVR And Test Check AMP Draw Check Load Distribution Conduct 12 Volt...

Страница 30: ...W W SENSING WINDING 0 4 0 4 0 4 BLUE BROWN NOTE THESE READINGS WILL VARY DEPENDING ON AMBIENT TEMPERATURE POWER TECHNOLOGY SOUTHEAST INC 634 STATE ROAD 44 LEESBURG FL 34748 8103 352 365 2777 FAX 352 7...

Страница 31: ...SENSING WINDING 0 4 0 4 0 4 BLUE BROWN NOTE THESE READINGS WILL VARY DEPENDING ON AMBIENT TEMPERATURE POWER TECHNOLOGY SOUTHEAST INC 634 STATE ROAD 44 LEESBURG FL 34748 8103 352 365 2777 FAX 352 787 5...

Страница 32: ...85 W NOTE THESE READINGS WILL VARY DEPENDING ON AMBIENT TEMPERATURE POWER TECHNOLOGY SOUTHEAST INC 634 STATE ROAD 44 LEESBURG FL 34748 8103 352 365 2777 FAX 352 787 5545 AC ELECTRICAL CIRCUIT FOR MB G...

Страница 33: ...NOTE THESE READINGS WILL VARY DEPENDING ON AMBIENT TEMPERATURE POWER TECHNOLOGY SOUTHEAST INC 634 STATE ROAD 44 LEESBURG FL 34748 8103 352 365 2777 FAX 352 787 5545 AC ELECTRICAL CIRCUIT FOR MB GENER...

Страница 34: ...BLUE BROWN NOTE THESE READINGS WILL VARY DEPENDING ON AMBIENT TEMPERATURE POWER TECHNOLOGY SOUTHEAST INC 634 STATE ROAD 44 LEESBURG FL 34748 8103 352 365 2777 FAX 352 787 5545 AC ELECTRICAL CIRCUIT FO...

Страница 35: ...BROWN NOTE THESE READINGS WILL VARY DEPENDING ON AMBIENT TEMPERATURE POWER TECHNOLOGY SOUTHEAST INC 634 STATE ROAD 44 LEESBURG FL 34748 8103 352 365 2777 FAX 352 787 5545 AC ELECTRICAL CIRCUIT FOR 8K...

Страница 36: ...UE BROWN NOTE THESE READINGS WILL VARY DEPENDING ON AMBIENT TEMPERATURE POWER TECHNOLOGY SOUTHEAST INC 634 STATE ROAD 44 LEESBURG FL 34748 8103 352 365 2777 FAX 352 787 5545 AC ELECTRICAL CIRCUIT FOR...

Страница 37: ...E THESE READINGS WILL VARY DEPENDING ON AMBIENT TEMPERATURE POWER TECHNOLOGY SOUTHEAST INC 634 STATE ROAD 44 LEESBURG FL 34748 8103 352 365 2777 FAX 352 787 5545 AC ELECTRICAL CIRCUIT FOR 10 12KW C GE...

Страница 38: ...ize Compartment Frame Air Requirements SYSTEMS CONNECTION 7 12 Remote Radiator Cooling System Remote Radiator Cooling System with AC Fan Remote Radiator Cooling System with DC Fan Fuel System Exhaust...

Страница 39: ...d be well ventilated to prevent the accumulation of explosive gases To avoid sparks never disturb the battery charging connections while the battery is being charged Always turn off the battery charge...

Страница 40: ...to avoid electrical connections by contacting the battery terminals with tools Remove wristwatch rings and all jewelry when working on the generator set 12 BACKFIRE A sudden backfire can cause seriou...

Страница 41: ...s a Kubota diesel engine rotating field alternating current generator and a relay controller The generator is directly connected to the engine for permanent alignment Each controller includes a Start...

Страница 42: ...here be sufficient room around the set to maintain the minimum clearance of one inch 2 AIR REQUIREMENTS Are the compartment air inlets and outlets sized to allow adequate circulation of air for coolin...

Страница 43: ...mpartment Line the compartment with a good sound deadening material The material selected must be fireproof or highly fire resistant An available type of 3 layer foam material is very efficient for ab...

Страница 44: ...compartments and interior spaces Plugging holes and sealing all seams will greatly reduce this hazard WARNING Drip Proofing When installing a generator the area directly beneath the generator end of t...

Страница 45: ...enerally the discharge chute opening should be approximately one and one half times the size of the radiator core NOTE If the radiator is to be located in a compartment separate from the engine refer...

Страница 46: ...s of flexible fuel line to make the connection Use proper size fuel line to accommodate the fuel flow needed Steel fuel line or high quality fuel hose is recommended either one should have a minimum o...

Страница 47: ...ust system in located in an area which may become susceptible to road damage from curbs speed bumps or other road obstacles a protective device such as a skid bar or plate should be installed 7 To pre...

Страница 48: ...12...

Страница 49: ...te battery cables should be kept short in length thus eliminating problems with excessive voltage drop See the Table below for cable size AWG to length requirements NOTE A heavy gauge 4 ground strap m...

Страница 50: ...g and running requirements of some motor loads common to mobile applications are listed in the table below Use this as a guide when selecting generator set capacity requirements involving motor loads...

Страница 51: ...0 SUMP PUMP 1 3 HP 500 REFRIGERATOR 500 FURNACE FAN 1 3 HP 600 FREEZER 800 JET WATER PUMP HP 900 ELECTRIC STOVE ELEMENT 1000 SUBMERSIBLE WATER PUMP 1 HP 1000 TOASTER 1000 COFFEE MAKER 1200 DISHWASHER...

Страница 52: ...ndby Current Draw 175mA Operating Current Draw Internally Protected against Reverse Polarity Speed Sensing accepts Generator AC Output Speed Sensing rated to a Maximum of 300V AC 40 C to 85 C Operatin...

Страница 53: ...d relay Replace fuse relay and re test controller again Out of fuel Check fuel level add fuel if necessary Ignition control wiring not installed properly Refer to engine control wiring and check ignit...

Страница 54: ...p the engine will immediately shut down and go into a fault mode Likewise for a high temperature situation 8 If engine will not start on the first attempt the PT ECU 63 will initiate the start cycle 2...

Страница 55: ...12 VOLT DC CHARGING BLUE to 12V GENERATOR WINDING BLUE to 12V GENERATOR WINDING RED to 12V DC YELLOW to RUN RELAY BLACK to GROUND GREEN NOT USED 06REG12DC 06REG12DCAT 19...

Страница 56: ...12V DC ENGINE CONTROL PT ECU 63 POWER TECHNOLOGY SOUTHEAST INC 634 STATE ROAD 44 LEESBURG FL 34748 8103 352 365 2777 FAX 352 787 5545...

Страница 57: ...OVERLOAD CONDITION Check AMP Draw Check Load 10 Engine Problem See Engine Troubleshooting Check Stator Coil Resistance Replace Stator...

Отзывы: