background image

 5 

TROUBLESHOOTING 

 

NO INDICATOR LIGHT 

- If the indicator light is dark, check the fuse and replace if necessary. If the fuse 

is good, check the voltage switch setting and input power (is the receptacle controlled by a light 
switch?). If all else appears normal then the charger probably needs repair. 
 

NO CHARGE INDICATOR, NOT CHARGING 

- If the charger will not go into charge mode (yellow indica-

tor) then the battery is probably already charged. Try again with another battery which you know is 
not charged. 
 

FAULT INDICATOR 

- If the indicator light is red then either the outputs are hooked up in reverse or 

shorted together. Make sure of the connection to the battery. Note: A nearly completely dead battery 
(less than one volt) looks like a short to the charger. If you suspect the battery is dead, leave the 
charger on the battery to see if it will go into charge mode. The charger will deliver a small amount of 
current into a dead battery and may eventually go into normal charge mode and recover the battery. 
If the charger will not go into charge mode within one hour, and then into float mode within 24 hours, 
the battery is probably damaged beyond recovery. 
 

MAINTENANCE INSTRUCTIONS 
 

FUSE REPLACEMENT - The AC input module contains the main fuse and a spare fuse. Detach the 
power cord. Use a flat head screwdriver or a coin to pry open the fuse drawer or holder. Replace the 
blown fuse with the spare. You can use the old fuse to push out the spare fuse. Now is a good time to 
install a new spare fuse. Replace fuses only with the same type (as indicated in this manual) and value 
(as indicated on the charger). 
 
CLEANING - Unplug the charger before attempting any cleaning. If it becomes necessary to clean the 
enclosure, wipe the exterior of the enclosure with a damp cloth and a mild detergent. Do not use an 
abrasive cleanser. Do not spray cleaners directly onto the charger or immerse unit in water. 
 

BATTERY CHARGER SPECIFICATIONS 
 

Operating temperature 

  

0 to 35° C (32 to 95° F) 

Storage temperature   

 

 -40 to 80° C (-40 to 176° F) 

Dimensions  

 

 H 3.40” (8.6cm) x W 6.65” (16.9cm) x D 5.30” (13.5cm) 

Weight  

 

About 7.4lbs. (3.4kg) 

Input fuse type  

 

5x20mm fast acting, miniature glass fuse, UL & CSA approved. 

Power Requirements 

  

115/230 V~, 50-60 Hz, .98 A RMS 

 

OUTPUT RATING @ 25° C 

 
Charge Amps (lmax)   

 

4A ± 2% 

Charge Voltage Load With Battery   14.70 ± 0.30 
Load With Battery  

 

 

2.00A 

Float Voltage Load with battery  

13.68± 0.12 

Switch Amps (lsw)  

 

 

2A ± 5% 

Содержание PSC-124000AP

Страница 1: ...odel PSC 124000AP CAUTION TO PREVENT THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER NO USER FRIENDLY PARTS CAUTION THIS UNIT SHOULD NOT BE USED IN OUTDOOR APPLICATIONS EXPOSURE TO MOISTURE MAY RESULT IN FIRE OR SHOCK HAZARD OPERATING PROCEDURES AND SAFETY INSTRUCTIONS ...

Страница 2: ...maintenance free rechargeable batteries Attempting to charge other types of batteries may result in personal injury and battery damage The heat sink and enclosure will become hot during the charge cycle DO NOT TOUCH Connect or disconnect the output connectors only when the unit is disconnected from AC power or arcing and burning may result due to the possible presence of explosive gases DANGER Nev...

Страница 3: ...ntermittent parallel load The use of an optional low voltage cut out is rec ommend when using parallel loads This unit is not designed to operate as a standalone power supply OPERATING INSTRUCTIONS Before using this battery charger make sure it is compatible with your battery Refer to the ratings on the battery charger the specifications in this manual and your battery documentation Determine the ...

Страница 4: ...ge It will increase the charge voltage in cold conditions and decrease charge voltage in warm conditions For this feature to work properly the battery and charger should be located in the same environment allow the battery and charger to stabilize at room temperature before charging Initially the charger open circuit voltage may read a little high until its internal temperature warms during operat...

Страница 5: ...hin 24 hours the battery is probably damaged beyond recovery MAINTENANCE INSTRUCTIONS FUSE REPLACEMENT The AC input module contains the main fuse and a spare fuse Detach the power cord Use a flat head screwdriver or a coin to pry open the fuse drawer or holder Replace the blown fuse with the spare You can use the old fuse to push out the spare fuse Now is a good time to install a new spare fuse Re...

Страница 6: ...6 Power Sonic Corporation 7550 Panasonic Way San Diego CA 92154 Tel 619 661 2020 Fax 619 661 3650 E Mail quality assurance power sonic com Website http www power sonic com ...

Отзывы: