TRACKSO INSTALLATION GUIDE FOR POWER ONE INVERTERS 

 

Brand:

 POWERONE 

Type:

  Solar On Grid String Inverter 

Models:  

10kW-SGTU-103, 12.5kW-SGTU-1253, 15kW-SGTU-153, 17kW-SGTU-173, 20kW-SGTU-203, POM 

SGTU 30kW, SGTU-333N, POM SGTU 50kW 

DOCUMENT DETAILS 

Following Document Explains Connections of TrackSo Logger with PowerOne Inverters for Following Type 

1)

 

10kW-SGTU-103, 12.5kW-SGTU-1253, 15kW-SGTU-153, 17kW-SGTU-173, 20kW-SGTU-203, SGTU-333N 

a.

 

Type A- with RS485 Output  

b.

 

Type B- with RS232 Output 
 

2)

 

POM SGTU 30kW, POM SGTU 50kW, POM SGTU 60kW (RS485) 

 

 

 

 

For a Modbus-RTU-RS232 type Inverter you will require logger with RS232 Communication port. 

For a Modbus-RTU-RS485 type inverter you will require logger with RS485 Communication port. 

 

 

 

 

Note: 

 

 

Before Proceeding further kindly identify the Inverter type you are 

connecting with the Datalogger and accordingly proceed with the instruction 

mentioned for that model

 

Содержание 10kW-SGTU-103

Страница 1: ...kW SGTU 103 12 5kW SGTU 1253 15kW SGTU 153 17kW SGTU 173 20kW SGTU 203 SGTU 333N a Type A with RS485 Output b Type B with RS232 Output 2 POM SGTU 30kW POM SGTU 50kW POM SGTU 60kW RS485 For a Modbus RT...

Страница 2: ...GURATION AT THE INVERTER END SETTING THE BAUD RATE The communication baud rate is to be set at 9600 bit s SETTING THE INVERTER ID The inverter ID is used to identify the inverter in a RS485 connection...

Страница 3: ...ease make the connections from the connector RS232 of PowerOne Inv RS232 Output to TrackSo IoT Gateway as mentioned in the Table KT2 4 Please provide 12V external supply to TrackSo IoT Gateway via 12V...

Страница 4: ...ter settings SETTING THE BAUD RATE The communication baud rate is to be set at 9600 bit s Menu Setup Comm Param Baud Rate SETTING THE INVERTER ID The inverter ID is used to identify the inverter in a...

Страница 5: ...monitoring system date and time have to be correct Menu Setup System Param Time Set The above details are mentioned in the Installation Operation Manual for PowerOne Inverters Valid for 10kW SGTU 103...

Страница 6: ...the RS485 terminal as shown in A part of Figure K1 Please make the connections from the Terminal Block to TrackSo IoT Gateway as mentioned in Table P2T1 Table PT2 PowerOne RS485 connections with Track...

Страница 7: ...9200 38400 Data Bits 8 Stop Bit 1 Parity None CONFIGURATION AT THE INVERTER END Press Enter on LCD panel and get into settings menu After entering into the setup interface the system will prompt to in...

Страница 8: ...input figure confirm input and return back setup interface by pressing ENTER button press ESC button to cancel input and return back setup interface the input numerical value is between 1 and 32 Opti...

Страница 9: ...e installed location LED NAME DESCRIPTION GREEN POWER Light when Power on the device RED GSM LED Status Connection State Flashing ON for 100ms and OFF for 100ms SIM Card not found Flashing ON for 500m...

Страница 10: ...ed NC not connected PIP Connected to TrackSo Server or not CONT connected NC not connected LOG no of data points stored in devices incase of no interet 6 If the GSM light starts flashing 5 times then...