background image

WARNINGS

 

CONTINUED:

 

DANGER

 

OF

 

EXPLOSION.

 

BATTERY CHARGING,

 

DISCHARGING

 

AND

ENGINE

 

OPERATION

 

PRODUCE

 

EXPLOSIVE

 

GASSES.

 

MAKE

 

SURE

 

THE

AREA AROUND

 

THE

 

BATTERY IS

 

WELL VENTILATED

 

AND

 

NO

 

BATTERY

CHARGING

 

IS

 

OCCURRING.

 

WEAR

 

PROTECTIVE

 

EYEWEAR

 

WHILE

CONNECTING

 

TO

 

NON-SEALED

 

LEAD

 

ACID

 

BATTERY.

  

Place

 

the

 

inverter

 

as

 

close

 

to

 

the

 

battery

 

supply

 

a

 

practical

 

making

 

sure

 

the

 

inverter

is

 

secure,

 

dry,

 

and

 

cool.

Make

 

sure

 

the

 

length

 

and

 

gauge

 

of

 

cable

 

are

 

correct

 

for

 

the

 

installation.

 

(See

Appendix

 

A)

 

Use

 

cables

 

that

 

have

 

6”

 

of

 

extra

 

length

 

for

 

stripping

 

insulation

 

and

fastening

 

(crimping

 

or

 

soldering)

 

ring

 

terminals.

CONNECTION

 

PROCEDURE:

1. Make

 

sure

 

the

 

inverter's

 

On/Off

 

Switch

 

is

 

turned

 

OFF.

2. Identify

 

the

 

Positive

 

and

 

negative

 

terminals

 

on

 

the

 

12

 

volt

 

DC

 

battery

 

and

identify

 

the

 

positive

 

(+)

 

and

 

negative

 

(-)

 

terminals

 

on

 

the

 

inverter.

 

3. Loosen

 

the

 

terminal

 

screws

 

from

 

the

 

terminal

 

connections.

 

4. Attach

 

the

 

red

 

cable

 

terminal

 

connecction

 

to

 

the

 

Positive

 

(POS

 

or

 

“+”)

terminal

 

and

 

the

 

black

 

cable

 

terminal

 

connection

 

is

 

attached

 

to

 

the

Negative

 

(NEG

 

or

 

“-”)

 

terminal

 

of

 

battery.

 

Secure

 

the

 

cables

 

by

 

tighting

 

the

 

flathead

 

screws

 

on

 

the

 

terminals.

5. Remove

 

the

 

retaining

 

nut

 

and

  

washer

 

from

 

the

 

grounding

 

terminal.

6. Carefully

 

attach

 

a

 

single

 

stranded

 

insulated

 

AWG

 

12

 

ground

 

wire

 

to

 

the

grounding

 

stud

 

on

 

the

 

back

 

of

 

the

 

inverter.

 

7. Replace

 

the

 

washer

 

and

 

nut

 

on

 

the

 

grounding

 

stud.

8. Connect

 

the

 

other

 

end

 

of

 

the

 

wire

 

to

 

Vehicle

 

Chasis

 

(non-moving

 

engine

 

part)

 

or

 

Earth

 

Ground.

 

See

 

Figure

 

4

 

for

 

connection

 

diagram.

9.

Attach

 

the

 

fuse

 

holder

 

to

 

the

 

red

 

cable

 

end

 

close

 

to

 

the

 

battery.

10. Prepare

 

a

 

very

 

short

 

AWG

 

4

 

cable

 

with

 

ring

 

terminals

 

to

 

connect

 

the

other

 

end

 

of

 

the

 

fuse

 

holder

 

to

 

the

 

battery

 

POS

 

terminal

 

of

 

the

 

battery.

FIGURE

 

4

 

-

 

THE

 

INVERTER

 

AND

 

FUSE

 

AND

 

SAFETY WIRE

 

CONNECTIONS


+

GND

+

INVERTER

12

 

VOLT

BATTERY

ANL FUSE

HOLDER

AND

 

300

 

AMP

FUSE

9

NOTE: DO

 

NOT CONNECT THIS

SAFETY WIRE

 

TO

 

THE

NEGATIVE

 

DC

 

INPUT

TERMINAL OF

 

THE

 

INVERTER

CHASIS

Содержание VEC550POB

Страница 1: ...ETY OPERATION MAINTENANCEAND STORAGE OF THIS PRODUCT BEFORE USE READAND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 SW 28th Way FT LAUDERDALE FL 33312 Tel 954 584 4448 Fax 954 584 5556 Toll Free 866 584 5504 ...

Страница 2: ...Disconnect DC power before servicing 6 Not approved for marine applications CAUTIONS 1 No user serviceable components inside opening unit will void warranty 2 Do not use with positive ground electrical systems the majority of modern automobiles RVs and trucks are negative ground Reverse polarity connection will result in a blown fuse may cause permanent damage to the inverter and will void the war...

Страница 3: ...ll Power on Board inverters have two methods of preventing batteries from being completely discharged When your batteries begin to drop in voltage the inverter will sound an alarm You can either turn off the inverter or leave it unattended Further discharge will automatically turn off the inverter If your battery does go to complete discharge it s because some other appliances are drawing power fr...

Страница 4: ...ED that lights when the inverter is operating One ON OFF switch that shuts off all inverter functions The ON OFF switch can also be used to reset the inverter after the inverter shutsdown due to a fault condition such as overload over temperature short circuit or high voltage FIGURE 1 FRONT PANEL FIGURES 2A SIDE VIEW FIGURES 2B CABLES 4 AC OUTLET FANS GROUNDING TERMINAL FAULT LED Red POWER LED Gre...

Страница 5: ...NOT plug small appliances into the inverter receptacles to directly recharge their nickel cadmium batteries Always use the recharger provided with that appliance Do NOT plug in battery chargers for cordless power tools if the charger carries a warning that dangerous voltages are present at the battery terminals Not all fluorescent lamps operate properly with this type of inverter If the bulb appea...

Страница 6: ...procating Saw 720 watts 1 3 Submersible Pump 920 watts Mini Microwave 1000 watts Chest Freezer 1200 watts Full Sized Microwave Oven 1400 watts NOTE APPLIANCE SPECIFICATIONS MAY VARY FROM BRAND TO BRAND THIS TABLE IS OFFERED ONLY AS A GUIDE TO APPROXIMATE POWER RATINGS CHECK APPLIANCE MANUALS OR PRODUCT LABELING FOR ACTUAL RATINGS TO ESTIMATE THE POWER CONSUMPTION OF APPLIANCE MULTIPLY CURRENT RATI...

Страница 7: ... INVERTER or Battery At full 1500 watt load the DC input requirements are up to 150 amperes at 12 volts DC For most continuous duty applications multiple battery configuration and the use of deep cycle batteries is a requirement With vehicles using multiple batteries inverters should be operated from one of the vehicles 12 volt batteries so there s always one battery with adequate charge to start ...

Страница 8: ...nerally battery capacity should be rated at least twice the calculated amp hours MOUNTING THE INVERTER The inverter should be mounted and close to the battery supply as safe from engine fumes explosive gas and high temperatures The inverter must have nonrestrictive airflow to maintain adequate cooling Use appropriate screws or other means to fasten the inverter to a shelf floor wall etc Make sure ...

Страница 9: ...terminal connections 4 Attach the red cable terminal connecction to the Positive POS or terminal and the black cable terminal connection is attached to the Negative NEG or terminal of battery Secure the cables by tighting the flathead screws on the terminals 5 Remove the retaining nut and washer from the grounding terminal 6 Carefully attach a single stranded insulated AWG 12 ground wire to the gr...

Страница 10: ...t Power on Board Technical Support at 954 584 4446 EXT 119 for professional direction SERVICE AND REPLACEMENT PARTS FUSES It is recommended but not required since there is internal fuse protection that the user use an external inline ANL 300 fuse and fuse holder not supplied The fuse holder and the ANL 300 fuse not supplied can be purchased at most electrical supply companies It is also recommende...

Страница 11: ...tenna Do not operate high power appliances or tools when you are watching TV TROUBLESHOOTING GUIDE TROUBLE INDICATION POSSIBLE CAUSE SUGGESTED REMEDY No AC output Green POWER LED DC input below 10 Volts Recharge or replace battery not lit FAULT LED not lit No AC output Green POWER LED DC Input fuse s blown Investigate for short circuit repair not lit FAULT LED not lit replace with same type fuse L...

Страница 12: ...an Standard Power Transistor Type MOSFET Weight 7 3 lbs Length 10 825 in Width 8 5 in Height 3 12 in APPENDIX A PROPER GAUGE CABLE FOR 2 3 PERCENT DC VOLT LOSS 2 CONDUCTOR COPPER MAXX UL SERIES INVERTER CONTINUOUS WATTAGE LENGTH FT 800 1000 1500 3000 2 8 8 6 3 4 6 4 3 1 O 6 4 3 2 2 O 8 3 2 1 O 4 O 10 2 1 2 O 250mcm 12 1 1 O 2 O 300mcm 14 1 1 O 3 O 350mcm 16 1 O 2 O 4 O 350mcm 18 1 O 2 O 4 O 400mcm...

Страница 13: ...ing the warranty period Power on Board Manufacturing Ltd will be responsible for the return shipping charges lIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations un...

Отзывы: