background image

DC TO AC POWER INVERTER 

 

 

     

                             

  

 

 
 
 
 

 
 

 
 
 
 
 
 
 

 

L-Series User Manual 

  

 

           

 

Before install and use your Inverter,  

read the User Manual and safety instructions.

 

12V / 24V / 48Vdc Input 

115V / 230Vac Output 

150W ~ 6000W Output cont. 

Cooler housing design!! 

Anytime, Anywhere 

Power it up wherever you go!!

 

 

 

 

 

  

VER.C/980720 

Содержание 0150LN

Страница 1: ...ser Manual Before install and use your Inverter read the User Manual and safety instructions 12V 24V 48Vdc Input 115V 230Vac Output 150W 6000W Output cont Cooler housing design Anytime Anywhere Power...

Страница 2: ...ns 3 E Front View Main Functions 5 F Rear View Main Functions 7 G Pre Installation Information 8 H Electrical Requirements 8 I Installation Requirements 8 J Connection and Testing 10 K Operation 11 L...

Страница 3: ...ard specially designed AC and DC line filters Panel indicators for battery voltage load level Specific chassis for harsh environments Standard inputs 12V 24V 48V Custom design No problem with microwav...

Страница 4: ...ash immediately with soap and water If acid gets into eyes immediately flood eyes with running cold water for at least 20 minutes and get medical attention immediately NEVER smoke or allow a spark or...

Страница 5: ...5 E Front View Main Functions 0150LN 0350LN 0650L 1200L 1800L 3000L 6000L...

Страница 6: ...r Temp Over Temperature Protection Under Volt Under Voltage Protection Over Load Over Load Protection Power Power ON Run Green Power Indicates current operating condition of the inverter 3 AC outlet O...

Страница 7: ...7 F Rear View Main Functions 0150LN 0350LN 0650L 1200L 1800L 3000L 6000L...

Страница 8: ...plash on the inverter free of salt or moisture laden air Temperature Ambient air temperature should be between 0 and 40 Safety Do not install in a battery compartment or other areas where flammable fu...

Страница 9: ...e inverter to a suitable surface paying close attention to the mounting requirements previously mentioned in this manual 2 AC Wiring Important to satisfy warranty requirements and conditions a qualifi...

Страница 10: ...terminal on the inverter The connection to the negative NEG terminal of the Inverter should be the last connection made A spark when making this final connection is normal 3 Before proceeding further...

Страница 11: ...olts to 16 volts for 12V models and 20 volts to 32 volts for 24V models and 42 volts to 62 volts for 48V models from 150Watts up to 6000Watts 2 Over voltage indicator The over voltage indicator indica...

Страница 12: ...n is indicated by the inverter turning off after every eight to ten seconds then back on again The AC Status lamp will also be flashing orange There are two possible solutions Increase the sensitivity...

Страница 13: ...mptoms Possible Cause Solution Low output voltage Using average reading Use true RMS and cable 110V 95 105VAC Voltmeter See page 7 Point 6 7 of manual 220V 190 210VAC Load LED flashes Overload Reduce...

Страница 14: ...16 VDC 20 32 VDC 42 62 VDC 20 32VDC 42 62VDC Green Power Recovery Time 1 Second LED Status Indication RUN trip Green power LED All in one Power ON OFF RUN STAND BY High Low Battery Shutdown Over Tempe...

Отзывы: