8843641
Pistol Grip Air Shear
V1.0
12
For technical questions call 1-800-665-8685
Problem(s)
Possible Cause(s)
Suggested Solution(s)
Tool runs slowly.
Air flows slightly
from exhaust.
1. Air regulator in closed
position.
2. Damage or excessive
wearing of internal parts.
1. Open the air regulator to
desired airflow.
2a. Have a qualified technician
service the tool.
2b. Replace tool or parts.
Tools will not run.
Air flows freely
from exhaust.
Damage or excessive
wearing of internal parts.
1.
Have a qualified technician
service the tool.
2. Replace tool or parts.
Tool will not shut
off.
1. Throttle valve o-ring
dislodged from inlet
valve seat.
2. Trigger mechanism
jammed or dirty.
1. Replace throttle valve
o-rings.
2. Clean trigger mechanism and
lubricate.
Loss of power or
erratic
performance.
1. Excessive drain on the
air hose. Incorrect size or
type of hose connectors.
2. Moisture or restriction in
the air hose/tank
3. Air compressor has
insufficient flow.
1. Check the air hose and
confirm the hose fitting is
correct for the inlet bushing.
2. Depressurize system and
drain tank and air hose of
water.
3. Ensure tool is connected to a
compressor with a rate flow
that matches the tool.