![Power Fist 8142564 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/power-fist/8142564/8142564_owners-manual_1586850008.webp)
Stopping Engine
1. Turn the engine switch to the OFF position.
2. Turn the fuel valve lever to the OFF position. When the engine is not in use, leave
the fuel valve lever in the OFF position to prevent carburetor flooding and to
reduce the possibility of fuel leakage.
Powering 120 Volt AC Tools And Equipment:
1. Prior to powering tools and equipment, make sure the generator’s rated voltage,
and amperage capacity (120V AC @ 19 AMPs) is adequate to supply all electrical
loads that the unit will power. If powering exceeds the generator’s capacity, it
may be necessary to group one or more of the tools and/or equipment for
connection to a separate generator.
CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC
EQUIPMENT WITHOUT THE USE OF AN APPROVED LINE
CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT.
2. Once the generator is running, simply connect the power cords of 120 volt AC
powered tools and equipment into the 120 volt AC dual outlets.
NOTE: THE GENERATOR FEATURES AN AC NON-FUSE CIRCUIT BREAKER
TO PROTECT THE AC CIRCUIT IN CASE OF AN OVERLOAD.
SHOULD AN OVERLOAD OCCUR, THE BREAKER WILL “TRIP” TO
ITS “OFF” POSITION, CAUSING THE GENERATOR TO AUTOMATICALLY SHUT DOWN. IN THIS
CASE, REFER TO ABOVE IN THIS POSITION. THEN, RESET THE CIRCUITRY SYSTEM BY
TURNING THE CIRCUIT BREAKER TO ITS “ON” POSITION. RESTART THE GENERATOR AND
CONTINUE POWERING THE REMAINING TOOLS AND EQUIPMENT.
3. Note: The Generator features an AC Non-Fuse Circuit Breaker “OFF” position. Turn the fuel valve to its “OFF”
position.
4. Disconnect all electrical powered tools and equipment from the generator’s 120 volt AC duel outlets.
Starting
1. Turn the engine switch to the ON position. The engine switch enables and
disables the ignition system.
OFF: To stop the engine
ON: To run the engine
2. The fuel valve is located under the fuel tank. When the valve lever is in the ON
position, fuel is allowed to flow from the fuel tank to the carburetor. Be sure to
return the fuel valve lever to the OFF position after stopping the engine.
3. To start a cold engine, move the choke lever to the CLOSED position. To restart a
warm engine, leave the choke lever in the OPEN position. The choke lever opens
and closes the choke valve in the carburetor. The CLOSED position enriches the
fuel mixture for starting a cold engine. The OPEN position provides the correct
fuel mixture for operation after starting, and for restarting a warm engine.
4. Operate the Recoil Starter: Pull the starter grip lightly until you feel resistance,
then pull briskly. Return the starter grip gently. Pulling the starter grip operates
the recoil starter to crank the engine
5. If the choke lever has been moved to the CLOSED position to start the engine,
gradually move it to the OPEN position as the engine warms up.
Содержание 8142564
Страница 1: ...2 800 Watt Generator 8142564 Owner s Manual...
Страница 13: ...Parts Diagram...