Powelectrics Metron 4 Скачать руководство пользователя страница 2

Getting to Know…

The Metron4

The Metron4 makes remote monitoring 
simple and affordable, interfacing with 
sensors, taking periodic readings and 
transmitting them over the mobile 
phone networks. 

•  Compatible with 1000s of sensors
•  Remotely programmable
•  Self-contained, weatherproof
•  Proven and reliable

Intelligent solar regulator maximises battery life and solar charging potential and 
includes pre charge conditioning if battery is in poor condition. There is also 
temperature com pensation, meaning charge rate is adjusted according to battery 
temperature, maximizing battery life.

Solar capability depends on orientation, sight of sun and location ( ie the further 
from the equator the less power from the sun). In England, 10 minute transmissions 
possible, in Scotland need a 2nd solar cell to achieve this.

Dimensions 

185 × 337 mm base plate

The Metron4 is housed in a panel with the barriers. This panel needs to be in the safe area and 
suitable sensors fitted in the field.

This augmented solution offers a sophisticated interface on site, with high resolution, colour 
display of actual process (eg tank levels & graphics). It is used where more complex calculations 
and commands are needed on site. MetronAS offers instant response to programmable inputs/
events, triggering immediate alarms and beacons Contact Powelectrics to discover more about 
MetronAS and bespoke, application specific solutions.

Enclosure 

400 × 300 mm wall mount panel with 
hinged door.

ATEX Barrier(s) 

Includes up to 4 ATEX barries,  
such  as MTL 554.

Sensor Cabling 

Consider inductance and capacitance of cable 
as well as characteristics of sensor. 
For SPS Ex (from Powelectrics) with 
LAPP12420 cable max. = 754m.

Metron4/S/SOL SYS

 runs from a 10 Watt solar power 

and lead acid battery via an intelligent charge regulator.

Metron4/S/...ATEX

 for use in explosive atmospheres. For 110/230 Vac power supply.

MetronAS

 (Augmented Solution)

Technical Specifications

Parameter

Details

Inputs

4 (4 – 20 mA, 0 – 10 V DC sensors or volt free contacts).
Expansion cards: 5 channel pulse (volt free, 10 Hz max.) & RS232 / R S485  
(contact Powelectrics regarding protocols).

Outputs

Optional 2 relay outputs controlled either remotely or when threshold breached.

Communications

GSM (4G (CatM1 / NB1) with 2G fallback – worldwide frequencies).

Data Logging

80 per channel, first in first out.

Power Supply

Battery, 6 – 24 Vdc, 110/230 Vac, internal battery and solar options.

Sensor Excitation

Will provide power to sensors (5 V or 21.6 V, 31 mA max.) for a programmable length of time.

Environmental

IP67, -20 to +65ºC.

Programming

Normally remotely from MetronVIEW or locally via USB (Windows software free of charge from 
Powelectrics. Mini USB not provided by Powelectrics).

Configurable Parameters

System

Inputs

Wake up interval (min: 1 min, max: 24 hr)

Type (analogue or digital)

Transmit interval (min: 5 min, max: 24 hr)

Tag name

Modem state (including idle, transmit on power 
up, pollable)

Units of measure

Zero & span (scaling) and linearisation

Antenna selection (internal or external)

Alarm thresholds (10 high (rising) and 10 low 
(falling))

Synchronisation time

Call out delay

Transmission window

Sensor excitation time and settling voltage

Display

The built-in back lit 40x40mm LCD display acts as a local gauge to help test the device and ensure 
it is communicating well. It is also used to check sensors and wiring. Can be used as a local display 
to show measured values on wake up.

138

75

68

Metron4/S

 runs on 6-24Vdc. Allow 0.5 A. Ensure supply is well regulated.  

For mains power 110/230 Vac, options are:

/MPSU

 Mains (110 / 230 Vac) 

power supply with backup 
battery and regulator, housed in 
a weatherproof enclosure and 
a Metron4 fixed on base plate 
(185 x 371 mm). Provides 6 Vdc 
to Metron4

UPS 12 V

 Uninterruptable power 

supply is a separate box  
(262 × 188 mm). Mains 110 / 230 
Vac in 12 Vdc maintained output via 
battery backup. Battery can typically 
support 50 transmissions. IP54 
protection rating. Run cable from UPS 
12 V to Metron4.

Battery life depends on regime. The Metron4 is designed to maximise battery life. More 
frequent readings, weak signal and cold temperatures will shorten battery life. Battery duration 
also dependent on the type of sensor used. Typical life is 4 years if powering a 2 wire, 4-20 
mA sensor for 2 seconds and transmitting once per day. Only use Powelectrics approved 
batteries.

Metron4/SSM

 runs from an internal battery.

Отзывы: