OM-183 304 Page 12
3-7. Installing Gas Supply
ssb3.1* 5/94
−
158 697-A
Obtain gas cylinder and chain to
running gear, wall, or other station-
ary support so cylinder cannot fall
and break off valve.
1
Cap
2
Cylinder Valve
Remove cap, stand to side of valve,
and open valve slightly. Gas flow
blows dust and dirt from valve.
Close valve.
3
Cylinder
4
Regulator/Flowmeter
Install so face is vertical.
5
Gas Hose Connection
Fitting has 5/8-18 right-hand
threads.
6
Flow Adjust
Typical flow rate is 20 cfh (cubic feet
per hour). Check wire manufactur-
er’s recommended flow rate.
Make sure flow adjust is closed
when opening cylinder to avoid
damage to the flowmeter.
7
CO
2
Adapter
8
O-Ring
Install adapter with O-ring between
regulator/flowmeter and CO
2
cylinder.
Tools Needed:
1-1/8, 5/8 in
CO
2
Gas
7
8
3
1
2
4
5
6
1
2
3
Argon Gas
OR
Содержание SGS 30A
Страница 1: ...Processes OM 183 304A September1998 SGS 30A Description MIG GMAW Welding Feeder Gun ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 25: ...OM 222 Page 19 SECTION 6 ELECTRICAL DIAGRAMS 138 956 B Figure 6 1 Circuit Diagram For Gun Feeder ...