Commissioning of solar controller
3.1.5 Menu “Info”
In this menu mode all measured values and operating
states are shown.
If the values are marked as “resettable”, they may be
reset in the following way:
Choose the value with buttons
and
Reset value by means of the button
Message “OK?” confirm with
= no or
= yes
Indication
Description
Reset possible
75ºC
Indication of current collector temperature
no
min. 12ºC
Indication of minimum collector temperature
yes
Re-settable to current temperature
max. 105ºC
Indication of maximum collector temperature
yes
Re-settable to current temperature
52ºC
Indication of current temperature storage tank (lower)
no
min. 40ºC
Indication of minimum temperature storage tank (lower)
yes
Re-settable to current temperature
max. 67ºC
Indication of maximum temperature storage tank (lower)
yes
Re-settable to current temperature
25ºC
Indication of universal temperature measuring points (T3)
no
55ºC
Indication of current temperature storage tank thermostat
no
60ºC
Indication of current temperature collector return
no
60ºC
Heating, cooling, temperature differential controller
no
heat source. Sensor T1...T6
35ºC
Temperature differential controller
no
heat target
1234 h
Operating hours for charging storage tank
Yes
Resettable to 0 h
927 kWh
Energy productivity for storage tank
Yes
Resettable to 0 kWh