9 Settings
9.1
List of parameters
9.1.1
Shortcuts menu
Tab.46 Functions accessible with the shortcut key
Parameter
Description
Adjustment range
Standby/operation
Boiler standby / start-up
Standby : Boiler put on standby.
The symbol is displayed.
The boiler's operating modes are deactivated.
The frost protection function is activated.
On : Putting the boiler into operation
316:Hot water boost
Forcing domestic hot water pro
duction.
On :
Activates forcing of domestic hot water.
The symbol
is displayed.
If a domestic hot water tank is connected to the
boiler circuit, the boiler will give priority to forcing
heating of the DHW tank, independently of the oth
er parameters.
Off : Deactivates forcing of domestic hot water.
Central heating mode CH1
Boiler operating mode.
On :
Heating is always activated.
The symbols ,
1 2 3
and are displayed.
Reduced :
Heating is deactivated.
The symbols ,
1 2 3
and are displayed.
Timed :
Heating is dependent on the time range program
med.
The symbols and
1 2 3
are displayed.
Off :
The boiler is shut down and frost protection is ac
tive.
The symbol is displayed.
Room temperature CH1
Room temperature set point in
comfort mode.
Hot water heating
Setting domestic hot water pro
duction.
On : Enables domestic hot water production.
Off :
Disables domestic hot water production.
The symbol
disappears from the display.
Eco : Not used.
Hot water temp setpoint
Domestic hot water temperature
set point.
9.1.2
Information menu
Tab.47 Information menu
Information
Description
Value
Room temperature
Is displayed if the control system unit is configured as a room
temperature appliance
Room temperature min
Room temperature max
Boiler temperature
Boiler flow temperature
°C
Outside temp
Outside temperature
°C
9 Settings
70
7609493 - v08 - 24072018