Potterton Gold Combi 28 HE LPG Скачать руководство пользователя страница 2

2

© Baxi Heating UK Ltd 2010

© Baxi Heating UK Ltd 2010 

All rights reserved. No part of this publication may

be reproduced or transmitted in any form or by any means, or stored in any
retrieval system of any nature (including in any database), in each case whether
electronic, mechanical, recording or otherwise, without the prior written
permission of the copyright owner, except for permitted fair dealing under
Copyrights, Designs and Patents Act 1988.

Applications for the copyright owner’s permission to reproduce or make other
use of any part of this publication should be made, giving details of the proposed
use, to the following address:

The Company Secretary, Baxi Heating UK Ltd, The Wyvern Business Park,
Stanier Way, Derby, DE21 6BF.

Full acknowledgement of author and source must be given.

WARNING:

Any person who does any unauthorised act in relation to a

copyright work may be liable to criminal prosecution and civil claims for damages.

1.0

Quick Reference Guide

3

2.0

Troubleshooting

4

3.0

Repressurising System

6

4.0

Clearances

7

5.0

Care of the Boiler

8

6.0

Legislation

9

7.0

Setting the Timer

10

8.0

Emergency

11

9.0

Warranty & Service

12

Section

Page

Contents

Boiler Controls - see opposite page

for Operating Quick Reference Guide

Propane

Potterton Gold Combi 28 HE 

LPG

G.C.N

o

49-393-30

0086

ISO 9001

FM 00866

The Benchmark Scheme

Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims
to improve the standards of installation and commissioning of domestic heating
and hot water systems in the UK and to encourage regular servicing to optimise
safety, efficiency and performance.

Benchmark is managed and promoted by the Heating and Hotwater Industry
Council. For more information visit 

www.centralheating.co.uk

Содержание Gold Combi 28 HE LPG

Страница 1: ...010 User Guide and Important Warranty Information Please keep these instructions in a safe place If you move house please hand them over to the next occupier Gold Combi HE A LPG Condensing Combination Boiler You can rely on ...

Страница 2: ...rce must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubleshooting 4 3 0 Repressurising System 6 4 0 Clearances 7 5 0 Care of the Boiler 8 6 0 Legislation 9 7 0 Setting the Timer 10 8 0 Emergency 11 9 0 Warranty Service 12 Section Page Contents Boiler C...

Страница 3: ...mestic Hot Water Indicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water Boiler Output Temperature In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in ...

Страница 4: ... on Reset Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure needle in the GREEN section between 1 and 2 5 bar If the reading falls below 1 bar repressurise the system as described in section 3 1 Does the display show an error code e g E133 E110 Boiler not working NO NO YES YES YES ...

Страница 5: ...oom Thermostat if fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible YES NO CONTACTYOUR INSTALLER OR SERVICE ENGINEER YES 1 2 3 4 5 P M 7 8 9 1 0 1 1 1 2 1 2 3 4 5 A M 7 8 9 1 0 11 12 0 ...

Страница 6: ...cate a leak on the central heating system Fig 2 Error Code E119 will be shown on the display 3 2 To Re Pressurise the System 1 Look at the boiler from underneath There will be two taps one connected to the cold inlet valve and one to the central heating return valve Do not operate these taps yet 2 Your installer will have left a short copper pipe with wing nuts the filling loop with you for safe k...

Страница 7: ... the following minimum clearances for Safety and Maintenance Fig 4 Top 200mm Bottom 150mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing This is the MINIMUM recommended dimension Greater clearance than this will aid installation and maintenance 7 If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation...

Страница 8: ... faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 or E130 is displayed overheat of the primary water or flue system has occurred Turn the selector switch to the reset position and hold for at least 5 seconds If the boiler does not relight or the code is displayed regularly contact your installer or service engineer 5 E119...

Страница 9: ... or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production certified by Notified Bodies 0086 For GB IE only 6 2 Benchmark Commissioning Checklist 1 Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you...

Страница 10: ...e on demand To set the time of day Turn the timer outer bezel clockwise to align the pointer with the correct time to the nearest 15 minutes ensuring that A M P M is considered Do not at any time attempt to turn the bezel anti clockwise To set the timed heating program Decide which times of the day the central heating is required The heating will operate when the white tappets are set to the outer...

Страница 11: ...rning their taps to the right towards the wall Fig 8 3 Call your Installer or Service Engineer as soon as possible If you smell gas Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Open windows and doors in the hazardous area Turn off the gas supply at the meter Warn any other occupants an...

Страница 12: ... You should always contact your installer first because the cause of the fault may not be related to the boiler If your installer confirms that the fault is with the boiler and he she can t repair it our friendly customer service team is on hand to help Simply call our service division heateam on 0844 871 1560 to book an engineer visit or for any general advice that you may need Our contact centre...

Отзывы: