34
ADJUSTMENT TABLE FOR HEATING ENGINEERS
Display on room control module RRG
Function
Basic setting
New
Program
.
No.
BUM parameter final user level
(set at factory)
setting *)
700
Stoer1
1
st
history value for fault code counter
Display
4)
701
StrPn1
1
st
history value for fault phase
Display
4)
702
StrDia1
1
st
history value for SW diagnostic code b0
Display
4)
703/706/ Stoer2 / Stoer3
2
nd
/3
rd
/4
th
and 5
th
history value for
Display
4)
709/712 Stoer4 / Stoer5
fault code counter
704/707/ StrPn2 / StrPn3
2
nd
/3
rd
/4
th
and 5
th
history value for
Display
4)
710/713 StrPn4 / StrPn5
fault phase
705/708/ StrDia2 / StrDia3
2
nd
/3
rd
/4
th
and 5
th
history value for SW
Display
4)
711/714 StrDia4 / StrDia5
diagnostic ode b0
715
Stoer_akt
Current value of fault code counter
Display
4)
716
StrPn_akt
Current value of fault phase
Display
4)
717
StrDia_akt
Current value of internal SW diagnostic code b0
Display
4)
718
BetrStd
Burner operating time
Display (h)
719
BetrStdHz
Heating mode operating time
Display (h)
720
BetrStdBw
Hot-water mode operating time
Display (h)
721
BetrStdZone
Zone operating time
Display (h)
722
InbetrSetz
Startup counter
Display (h)
723
Pmittel
Average boiler output
Display (kW)
724
MmiStatus
Current summer/winter setting for boiler module
Display
725
OT_SwVersLMU
Parameter level
Display
755
IonStrom
Display of actual ionization current value
Display
Other parameters displayed are not relevant for operation of EUROCONDENSE PLUS!
*) Note: Any new settings to be recorded in manual!
1) These parameters should be optimized for adaptation to the specific heating system!
2) These parameters should be adjusted only when absolutely necessary!
3) These parameters should never be adjusted!
4) For a list of the internal software diagnosis codes, see manual of the RRG (room control) service module for a selection of
fault codes, see table 6.