REPORT SENT TO
INSTALLER:
YES
NO
DATE:
SIGNATURE:
REPORT No:
INSTALLER NAME & ADDRESS:
SITE ADDRESS:
COMMISSIONING DATE:
COMMISSIONING REPORT
Brooks House, Coventry Road, Warwick, CV34 4LL.
Tel: (08706) 050607 Fax: (08706) 001516
1.0
BOILER
1.1
Type:
1.2
No. of Sections:
1.3
No. of Boiler/position
1.4
Serial No.
1.5
Fuel:
N/Gas
LPG
2.0
BURNER/CONTROLS
2.1
Type:
Atmospheric
Pre-Mix
2.2
Flame Detection
Probe:
UV Cell
Thermocouple
2.3*
Control Box Type:
2.4
Electrical Supply:
2.5
Main Gas Valve Type & Size:
2.6
Pilot Gas Valve Type & Size:
2.7
Gas Train Serial Number:
2.8
Gas Booster Type & Size:
2.9
Gas Booster Serial No:
3.0
BURNER SETTINGS
3.1
Main Burner Injector Size
mm
3.2
Pilot Burner Injector Size
mm
3.3
Electrode Setting
(to manufacturers instructions)
mm
3.4*
Ionisation Probe Setting
(to manufacturers instructions)
mm
3.5
Are Burners & Injectors Clean
4.0
FLUE SYSTEM CHECK
Yes
No
N/A
Conventional
Fan Assisted
Fan Dilution System
Monodraught System
4.1
Flue
Type
Plant Room Door Interlocked
4.2
Draught Stabiliser Fitted
4.3
Dampers Fitted
4.4
Fan Assisted Ventilation
4.5
Fan Interlock Checked
4.6
Is Flue System Clear
4.7
Flue Header Diameter
mm
4.8
Stack Diameter
mm
4.9
Approximate Overall Height of Flue
M
5.0
PRE-COMMISSIONING PRELIMINARY
CHECKS (See Notes)
Yes
No
N/A
5.1
Is boiler house ventilation as per the
relevant B.S.
5.2
Electricity supply fused, isolated & earth
wire connected.
5.3
Check external controls allow operation
5.4
Check boiler/system filled and pumps
operational & any isolation valves open
5.5
Check gas available at burner
5.5
Check gas available at burner
5.6
Check oil available at burner
5.7
Check gas meter fitted & sized
adequately
5.8
Check that gas pipe has been purged.
6.0
COMBUSTION
Pilot Low
High
Unit
6.1
Inlet Gas Supply Pressure
(Boilers running)
mbar
6.2
Burner Pressure
mmwg
6.3
Gas Rate
m
3
/hr
6.4*
Ionisation Probe/UV Cell Current
6.5
c
Air Shutter Position
----
6.6
O
2
%
6.7
CO
2
%
6.8
0CO
ppm
6.9
Gross Flue Gas Temperature
o
C
6.11
Ambient Temperature
o
C
6.12
Flue Draught
mm
wg
6.13
Burner Fan Static Pressure
mmwg
7.0
OPERATIONAL SAFETY CHECKS
7.1
Check Control Thermostat Operation
7.2
Check Limit Thermostat Operation
7.3
Check High/Low Thermostat Operation
7.4
Check For Gas Leaks
7.5
Check For Gas Leakage Past Valve Assembly
7.7*
Check Boiler Locks Out On Loss Of Flame Signal
7.8
Check boiler Locks Out On Air Pressure Switch
Operation
7.9
Check Boiler Locks Out On Gas Inlet Pressure
Switch
7.10
Check Boiler Locks Out On All Other Safety
Functions
7.11
Check For Flue Sillage
7.12
$
Check Thermocouple Operation
7.13
$
Check Thermocouple Interrupter Operation
7.14
Check Gas Booster Interlock Operational
Record INLET and OUTLET Pressure Switch Settings:-
INLET……………………… OUTLET………………………….
8.0
BOILER/SYSTEM CHECK LIST
8.1
Control Thermostat Setting
O
C
8.2
High/Low Thermostat Setting
O
C
8.3
Maximum Flow Temperature Recorded
O
C
8.4
Maximum Return Temperature Recorded
O
C
8.5
Boiler Water Pressure
8.6
Are Pipework Connections As Per Manual
Is Safety Valve Fitted
If So, SIZE:-…………………………..………….
PRESSURE RATING…………………...
YES
NO
8.8
Are Water Isolating Valves Fitted
8.9
Are Water Flow Switches Fitted
8.10
Are Return Water Shut Off Or Diverter
Valves Fitted
8.11
Is Shunt Pump Fitted
8.12
Is Pump Overrun Fitted