Installation of the equipment in a rack should be such that the amount of airflow
required for safe operation of the equipment is available.
Connect the unit only to a properly rated supply circuit.
During installation and service, do not connect to a live power source. Ensure
that fuses/breakers on the main power source are in the OFF/OPEN position or
that power cords are unplugged from the unit.
Mounting of equipment in a rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
WARNING:
The intra-building ports (Electrical Ethernet
– RJ-45, G.hn, V.24
console) of the equipment are suitable for connection to intra-building or
unexposed wiring or cabling only. The intra-building ports of the equipment
MUST NOT be metallically connected to interfaces which connect to the OSP or
its wiring. These interfaces are designed for use as intra-building Interfaces only
(Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 4) and require
isolation from the exposed OSP cabling. The addition of Primary Protectors is not
sufficient protection in order to connect these interfaces metallically to OSP
wiring.
THIS PRODUCT IS SUITABLE FOR MOUNTING ON OR ABOVE CONCRETE
OR OTHER NON-CONDUCTIVE SURFACE ONLY.