background image

Standalone Power Supply Unit 120 V dc to -24 V dc

17

7885-2 & 7885-3

5.

Service and Support

Technical Customer Support

Positron is committed to providing excellent ongoing technical support to its 
customers. A team of specialists is always available at our Technical Support 
Center in Montreal for either telephone consultations or on-site visits, to assist 
Field Technical personnel in the maintenance and troubleshooting of Positron 
equipment. During normal business hours, (8:30 a.m to 5:00 p.m. EST), any one 
of our Technical Customer Support (TCS) staff may be reached by dialing 
1-888-577-5254 from anywhere in the continental United States or from Canada. 
Customers outside North America should dial 1-514-345-2200. Staff may also be 
contacted via fax at 514-345-2271 or e-mail at [email protected].

Positron TCS staff are available to provide technical assistance and/or to 
supervise the installation of Positron equipment. Assistance in the planning, 
configuration, and implementation of the installation will be provided as 
requested. Arrangements and pricing information regarding field assistance may 
be obtained by contacting the Technical Customer Support department. Please 
contact Positron for scheduling at least four weeks prior to the actual requested 
visit date.

Customer Training

Positron offers full customer training courses, as requested. Seminars are also 
available on High Voltage Interface (HVI). For more information, contact a 
customer representative by dialing 1-888-577-5254 or use our e-mail address, 
[email protected].

Warranty

Positron warrants that all equipment shall perform in accordance with Positron’s 
specifications. The warranty remains valid for five (5) years from the date of 
shipment. The warranty will be honored provided that the equipment has not 
been abused and provided that the equipment has been installed and used in 
accordance with Positron’s installation instructions and specifications. The 
warranty fully covers workmanship, materials and labor.

This warranty is in lieu of all other warranties, whether expressed or implied, 
including warranties of merchantability and fitness for a particular purpose. 
Positron guarantees that all equipment shall perform in accordance with 
Positron’s specifications. Positron disclaims any warranty that Positron 

Содержание 7885-2

Страница 1: ...Standalone Power Supply Unit 120 V ac to 48 V dc 7885 2 7885 3 Description and Installation...

Страница 2: ...d 2 shall use same for operating and maintenance purposes only DISCLAIMER NOTICE Although Positron Inc has made every effort to ensure the accuracy of the information contained herein this document is...

Страница 3: ...nd Battery Unit 1 2 Hardware Description 4 3 Technical Specifications 6 4 Installation 7 4 1 Mechanical Installation 11 4 1 1 Wall Mount 11 4 1 2 Teleline Shelf Mount 12 4 2 Electrical Installation 13...

Страница 4: ......

Страница 5: ...attery Unit model 7885 3 holds two maintenance free backup batteries as does the Power Supply Unit model 7885 2 When the 7885 2 is connected to the 7885 3 the 7885 2 provides 5 7 ampere hours of batte...

Страница 6: ...7885 2 3 3 7 8 MOUNTING TRAY 7885 2 RIGHT SIDE VIEW 16 1 4 7885 2 FRONT VIEW POSITRON 7885 2 MOUNTING TRAY INPUT CABLE 9 2 3 INPUT FUSE ANCHORING BRACKET OUTPUT CONNECTOR 3 7 8 7885 3 RIGHT SIDE VIEW...

Страница 7: ...full wave rectification filtering and voltage regulation to perform the AC to DC conversion When model 7885 2 and 7885 3 are connected together they provide 5 7 ampere hours of charge at 48 V dc The...

Страница 8: ...dc 2 Hardware Description For the block diagram of model 7885 2 refer to Figure 2 Figure 2 Block Diagram Under Voltage Detection Rectifier Output Breaker Input Breaker Transformer Voltage Regulator Ba...

Страница 9: ...the filtered voltage from the input and gives out 48 V dc to the output Current Limit The Current Limit circuit is a linear current limit circuit that drops the output voltage as the current increase...

Страница 10: ...ameter Specifications Battery GS Battery 12V 5 7 A h P N PE12V7F1 or equivalent Input station voltage 104 to 127 V ac Input power at full load 160 VA Nominal output voltage 48 V dc Maximum output curr...

Страница 11: ...lation procedure It is preferable to perform these procedures on a clear dry day when a Ground Potential Rise GPR or transients are less likely to occur 1 Verify that you are not using any equipment w...

Страница 12: ...ards variations B and C only 7501 15B C OPX Trunk Card variation B only 7501 16B Four Wire AC Data Card 7501 24 Expandable Telephone Card configured for 24 V only 751321 751321 A 751321C Two wire HDSL...

Страница 13: ...r Card 7501 06A Four Wire T1 Carrier Card 751329 DC Trip DC Pilot Wire Card variation B only 7501 15B OPX Card variations B and C only 7501 16B C Four Wire AC Data Card 7501 24 Two Wire AC Data Card 7...

Страница 14: ...n document 1 7885 24 02 Battery backup case assembly 1 244 040029 401 Battery backup connection assembly 1 7885 03 02 Kit for power supply 1 241 010196 401 Power supply cable 1 207 010087 401 Phillips...

Страница 15: ...battery terminal Replace the power supply enclosure 4 1 Mechanical Installation The Standalone Power Supply Unit can be installed on a self supporting wall mounted tray or directly on the Teleline sh...

Страница 16: ...upply enclosure with those on the left side of the mounting tray Use the two 1 2 bolts and washers to attach the two parts together 4 Model 7885 3 may be stacked on top of the model 7885 2 4 1 2 Telel...

Страница 17: ...ad 0 12 or 36 volts there may be a polarity reversal of one or more batteries If there is a polarity reversal do not plug in the Power Supply Unit until the polarity reversal has been corrected For fu...

Страница 18: ...the standard AC cable and plug it to a 120 V ac outlet 7 Verify the installation by making sure that you obtain 48 V dc in the shelf 8 Test the battery backup after 24 hours of continuous operation o...

Страница 19: ...ssis out 3 Remove the metal plate holding the batteries to the chassis 4 Disconnect the batteries and dispose of them in a government approved waste site Caution The batteries contain toxic lead and c...

Страница 20: ...dc to 24 V dc Figure 4 7885 2 3 Component Layout PCB POWER TRANSFORMER 7885 3 COMPONENT LAYOUT TOP VIEW 7885 2 COMPONENT LAYOUT TOP VIEW HEAT SINK BATTERY BATTERY 12 V DC 12 V DC BATTERY BATTERY 12 V...

Страница 21: ...ents and pricing information regarding field assistance may be obtained by contacting the Technical Customer Support department Please contact Positron for scheduling at least four weeks prior to the...

Страница 22: ...ore please take this into consideration when requesting a Return Material Authorization RMA number Before returning any items to Positron for repair warranty repair or replacement call the Repair depa...

Страница 23: ...ate required on site All orders must be followed by a confirming order Equipment will not be shipped until such confirmation is received For a list of our contact information refer to Table 7 Table 7...

Страница 24: ......

Отзывы: