Figure 14: Start Wiegand Pulse Test in CW direction
3. The Wiegand Sensor Test status window will appear.
The “CW running” light will turn on.
Please
wait until the “CW done”
light turns on. The execution will take about 60 seconds.
Figure 15: Wiegand Sensor Test status window
4. Run the motor in CCW direction. Once the motion is established, confirm with
“OK”
button.
Figure 16: Start Wiegand Pulse Test CCW direction
5. After the CCW direction testing is finished successfully
, the “C
C
W done” light in the status window
will turn on. In the main Wiegand Sensor Test window,
the “
Test
done” light will turn on
and the
results will be shown in the result panel. The average pulse height of the analyzed pulses and its
standard deviation is saved for CW and CCW direction. A Wiegand pulse height average minus 4x
standard deviation greater than 5.3 V is recommended for operation.