2
•
For dedicated interface BIT 7 of S2 must be set to OFF and BIT 8 of S2 set
to ON. Please refer to Fig 3.
Model CR-3102/3202 with Non-Dedicated Interface:
•
Connect the drawer to the computer as shown in Figure 1. Connect the
power adapter output to the Power Input jack.
•
Whenever the POS application software transmits the pre-set security code
to the COM1 (or COM2) port, the drawer will be opened. The pre-set
security code was preset by the manufacturer at (07 Hex) and can be
changed as shown in Fig 3. Under normal operations, the selected pre-set
code should be a non-displayable ASCII character. For example, a
hexadecimal number between 01 to 1F. Note that other RS232C devices can
be connected to the same serial port, as long as this preset security code
makes no influence to the other RS232C device.
•
For non-dedicated interface, BIT 7 of S2 must be set to ON and BIT 8 of S2
must be set to OFF. Please refer to Fig 3.
Model CR-3103/3203 with Parallel Interface:
•
Connect the drawer to the computer as shown in Figure 2. Connect the
power adapter output to the Power Input jack.
•
Whenever the POS application software transmits the pre-set security code
to the parallel LPT1 port, the drawer will be opened. The pre-set security
code was preset by the manufacturer at (07 Hex) and can be changed as
shown in Fig 3. Under normal operations, the selected pre-set code should
be non-displayable ASCII character. For example, a hexadecimal number
between 01 to 1F. Note that other parallel devices such as printer can be
connected to the same parallel port, as long as this preset security code
makes no influence to the other parallel devices.
Model CR-3101~3/3201~3 Keylock Operation:
:
Permanent lock the drawer.
:
Open the drawer by the key.
:
Automatic open the drawer by or the
computer control.
Содержание CR-3101
Страница 9: ...7 ...
Страница 10: ...8 ...
Страница 11: ...9 ...
Страница 12: ...10 ...
Страница 13: ...11 Figure 5 ...
Страница 14: ...12 Figure 6 ...