Regular Cleaning 

For regular cleaning of the bump bar, please use only adequate amount of mild 
kitchen cleaning detergent for obstinate stains and wipe it off with dry clean 
soft clothes. Don’t allow any liquid to seep in through any seam in the metal 
enclosure. It could also be a brilliant idea to seal the whole bump bar with thin 
transparent wrap foil and replace the foil regularly. 

Specifications

 

Buttons  10-key buttons  

(8 buttons for SERVE/PREV/RECALL/SIDE 
ON/SERVE/NEXT/RECALL/SIDE OFF; 2 buttons for reserved buttons)

 

I/O Port  RS-232 COM port 

DIP Switch  8-segment dip switch 

Temp  

& Humidity

 

Operation temp.: -25 to +70 

 / storage temp.: -30 to +80

   

Humidity: 10 to 90 %; 5 to 90 % (operation condition)

 

 

DIP SWITCH 

(Pin No.)

 

Functions 

Pin 7 

Pin 8 

Enabling or disabling DIP switch 

 

Pin 7 : OFF / Pin 8 : OFF 
Enabling SW1 ~ SW10 

 

Pin 7 : OFF / Pin 8 : ON 
Enabling SW1, SW2, SW5~SW7, and SW10 

 

Pin 7 : ON / Pin 8 : OFF 
Enabling SW3~SW5 and SW8~SW10 

Содержание BB-3000

Страница 1: ...f the Bump Bar Top View Bottom View Front View BB 3000 Bump Bar User Manual RS 232 Port Reset Button Status LED Indicator Rubber Pad Rubber Pad Fixed Portion 19100900010 Ver Original SERVE Button NEXT Button SIDE ON Button RECALL Button Reserved SIDE OFF Button SERVE Button PREV Button RECALL Button ...

Страница 2: ...0 to a specified COM port of your host terminal through a dedicated RS 232 cable 2 By using your dedicated application select the specified COM port and a baud rate 3 Enable the COM port you selected Jumper Setting for a Baud Rate To set a baud rate please adjust the dip switch on the main board of the device Refer to the following steps to locate the dip switch on the main board 1 Loosen and remo...

Страница 3: ...change Code page 1 Pin 3 OFF Pin 4 OFF Pin 5 OFF Pin 6 OFF SW1 E2h SW6 E1h SW2 D2h SW7 D1h SW3 B2h SW8 B1h SW4 A2h SW9 A1h SW5 C2h SW10 C1h Code page 2 Pin 3 ON Pin 4 OFF Pin 5 ON Pin 6 OFF SW1 62h SW6 61h SW2 52h SW7 51h SW3 32h SW8 31h SW4 A2h SW9 A1h SW5 C2h SW10 C1h Code page 3 Pin 3 ON Pin 4 ON Pin 5 ON Pin 6 ON SW1 E2h SW6 E1h SW2 D2h SW7 D1h SW3 B2h SW8 B1h SW4 22h SW9 21h SW5 42h SW10 41h ...

Страница 4: ...p foil and replace the foil regularly Specifications Buttons 10 key buttons 8 buttons for SERVE PREV RECALL SIDE ON SERVE NEXT RECALL SIDE OFF 2 buttons for reserved buttons I O Port RS 232 COM port DIP Switch 8 segment dip switch Temp Humidity Operation temp 25 to 70 storage temp 30 to 80 Humidity 10 to 90 5 to 90 operation condition DIP SWITCH Pin No Functions Pin 7 Pin 8 Enabling or disabling D...

Отзывы: