- 15 -
5.5. AEDEX/EMAX Mode Command List
Command
Code (hex)
Function Description
! # 1
[DATA]
CR
21 23 31
[DATA]
0D
Upper line display
Maximal
[DATA]
length is 20
! # 2
[DATA]
CR
21 23 32
[DATA]
0D
Bottom line display
Maximal
[DATA]
length is 20
! # 4
[DATA]
CR
21 23 34
[DATA]
0D
Upper line message scroll
Maximal
[DATA]
length is 60
! # 5
h h
:
m m
CR
21 23 35
h h
':'
m m
0D
Display time
h
,
m
= '0' ~ '9'
! # 8
n m
CR
21 23 38
n m
0D
Change attention code
n
,
m
= 1 ~ 20
! # 9
[DATA]
CR
21 23 39
[DATA]
0D
Two line display
Maximal
[DATA]
length is 40
! # 6
[DATA]
CR
21 23 36
[DATA]
0D
Upper line message scroll once pass
Maximal
[DATA]
length is 60
5.6. ADM787/788 mode command list
Command
Code (hex)
Function Description
CLR 0C
Clear
display
CR 0D
Carriage
return
SLE1 0E
Clear upper line and move cursor to upper
left-end position
SLE2 0F
Clear bottom line and move, Cursor to bottom
left-end position
DC0
n
10
n
Set period to upper line last n position
n
= 31H ~ 37H
DC1
n
11
n
Set line blinking, upper line
n
= '1' ~ '2'
n
= '1': up line
n
= '2': low line
DC2
n
12
n
Clear line blinking, upper line
n
= '1' ~ '2'
n
= '1': up line
n
= '2': low line
SF1 1E
Clear field 1 and move cursor to field 1, first
position
SF2 1F
Clear field 2 and move cursor to field 2, first
position