background image

9

Figure 5 - Replacement Parts Illustration for B65114

Replacement Parts for Model B65114

Item #

Part #

Description

Qty.

1

B65161

Extension Tube (19-1/2")

1

2

B65160

Extension Tube (16-1/2")

1

3

B65159

Extension Tube (8-1/2")

1

4

B65158

Extension Tube (6-1/8")

1

5

B65157

Extension Tube (3")

1

6

B65177

Male connector

1

7

B65153

Wedge Head (offset)

1

8

B65151

Serrated Saddle

1

9

B65156

Flat Base

1

10

B65154

Plunger Toe (offset)

1

11

B65155

Ram Toe (offset)

1

12

B65178

Rubber Head

1

13

B65152

Combination Head 90

0

1

14

B65123

1/2 Ton Spreader

1

15

434-6-3313-101

Dust Cover - Hose

1

16

434-6-3312-109

Dust Cover - Ram

1

17

B69478

Hose Coupler, Male

1

18

B69477

Ram Coupler, Female

1

19

B65187

4 Ton Hydraulic Ram

1

20

426-3-1301-203

Release Valve Knob

1

21

431-6-1702-404

Pump Handle

1

22

B65291

Hose w/ Coupler

1

23

324-4-1900-208

Oil Filler Screw

1

24

B65186

4 Ton Hydraulic Pump

1

25

B65067

Plastic Case 

1

-

B65114-L0

Label (not shown)

1

-

B65114-M0

Manual

1

Содержание PORTO-POWER B65114

Страница 1: ...efore using this product read this manual and follow all its Safety Rules and Operating Instructions SFA Companies 10939 N Pomona Ave Kansas City MO 64153 816 891 6390 sales blackhawk automotive com Made in China B65114 M0 rev 11 05 Porto PowerBlackhawkAutomotiveisalicensedtrademark U S PATENT 5 520 400 ...

Страница 2: ...E OR LOSS WHATSOEVER 3 ANY IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE SHALLBELIMITEDTOONEYEAR OTHERWISE THE REPAIR REPLACEMENT OR REFUNDAS PROVIDED UNDER THIS EXPRESS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER AND IS PROVIDED IN LIEU OFALL OTHER WARRANTIES EXPRESS OR IMPLIED 4 ANY MODIFICATION ALTERATION AB...

Страница 3: ...ning and knowledge It is recommended that an annual inspection be done by qualified personnel and that any missing or damaged parts decals warning safety labels or signs be replaced with factory authorized replacement parts only Any component of this Porto Power Kit that appears to be damaged in any way is worn or operates abnormally shall be removed from service immediately until such time as it ...

Страница 4: ...le until ram is fully extended then open release valve until ram has fully retracted 8 With ram fully retracted and release valve open place pump in horizontal position Locate and open oil filler screw on reservoir body near the back This will release air trapped within the reservoir Retighten the oil filler screw 4 All WARNING statements must be carefully observed to help prevent personal injury ...

Страница 5: ...d or in poor condition Do not use rams with bent or damaged coupler or damaged threads Under certain conditions the use of an extension with a hydraulic ram may not be advisable and could present a dangerous condition Avoid pinch points or crush points that can be created by the load or parts of ram To help prevent material fatigue if the ram is to be used in a continuous application the load shou...

Страница 6: ...e 1 2 Fill until oil is within 1 4 6 mm of the hole opening reinstall oil filler screw Changing oil For best performance and increased system life replace the complete fluid supply at least once per year 1 With ram fully lowered remove the oil filler screw from the pump reservoir as above 2 Lay the pump on its side and drain the fluid into a suitable container Note Dispose of hydraulic fluid in ac...

Страница 7: ...proximate load capacity of each function setup is illustrated below When two or more extension tubes are used together be sure to position the shortest tube further away from the ram Note Not all accessories in the illustrations provided in the Porto Power Kit A Push Stretch Extension Tube Clamp Ram Extension Tube Male Connector Flat Base Male Connector Ram Combination Head 900 Extension Tube iii ...

Страница 8: ...h new coupler Figure 4 Pump and ram illustration to bleed air TROUBLESHOOTING Symptom Possible Causes Corrective Action Ram will not extend Ram will not lift to full extension Spongy effect Ram bleeds off after lift Handle kick back Ram will not lower after unloading Poor performance Release valve not tightly closed Overload condition Fluid level low Air trapped in system Release valve not tightly...

Страница 9: ...56 Flat Base 1 10 B65154 Plunger Toe offset 1 11 B65155 Ram Toe offset 1 12 B65178 Rubber Head 1 13 B65152 Combination Head 900 1 14 B65123 1 2 Ton Spreader 1 15 434 6 3313 101 Dust Cover Hose 1 16 434 6 3312 109 Dust Cover Ram 1 17 B69478 Hose Coupler Male 1 18 B69477 Ram Coupler Female 1 19 B65187 4 Ton Hydraulic Ram 1 20 426 3 1301 203 Release Valve Knob 1 21 431 6 1702 404 Pump Handle 1 22 B65...

Страница 10: ... 1 9 B65172 Plunger Toe offset 1 10 B65169 Ram Toe offset 1 11 B65180 Rubber Head 1 12 B65173 Combination Head 90o 1 13 B65123 1 2 Ton Spreader 1 14 434 6 3313 101 Dust Cover Hose 1 15 434 6 3312 109 Dust Cover Ram 1 16 B69478 Hose Coupler Male 1 17 B69477 Ram Coupler Female 1 18 B65189 10 Ton Hyd Ram 1 19 426 3 1301 203 Release Valve Knob 1 20 430 6 1702 407 Pump Handle 1 21 B65291 Hose w Coupler...

Страница 11: ...Load lbs P Hydraulic working pressure psi and A Ram effective area in Example2 Model B65115 operating at 6 000 psi will generate what force Force 6 000 psi x 2 411 in2 14 466 lbs Load lbs Pressure of 4 Ton Ram where A 0 998 in2 psi Pressure of 10 Ton Ram where A 2 411 in2 psi 1 000 1002 415 2 000 2004 830 3 000 3006 1244 4 000 4008 1659 5 000 5010 2074 6 000 6012 2489 7 000 7014 2903 8 000 8016 33...

Страница 12: ...memo ...

Отзывы: