4
SAFETY INSTRUCTIONS
BEFORE USE
1. Before using this product, read the operator's manual
completely and familiarize yourself thoroughly with the
product, its components and recognize the hazards
associated with its use. Prepare the pump for use
(see Figure 2).
2. Verify that the product and the application are
compatible. Inspect before each use. Do not use if
bent, broken, leaking or damaged components are
noted.
3. Carefully remove the threaded plug in oil output port.
4. Connect coupler or hose of matching threads (refer to
specifications on page 3).
5. Check for leaks in the system and have repaired by
qualified personnel as needed. Before repairs are
made, depressurize system by opening the release
valve counterclockwise, but no more than 2 full turns.
6. Replace worn or damaged parts and assemblies
with Porto-Power Blackhawk Authorized Replace-
ment Parts only (See Replacement Parts Section).
Lubricate as instructed in Maintenance Section.
7. Ensure method of confirming load is accurate and
working properly. Have gauge or load cell accuracy
verified by qualified personnel on a yearly basis.
8. Pumps should be stored where protected from the
elements, abrasive dust, and damage. Pumps can
be stored horizontally or vertically, but preferably not
upside down. Storing or using a pump upside down
increases the risk of losing fluid from the reservoir
through the vented oil filler plug. If application calls for
use in upside down position, it may be advisable to
reinstall the shipping plug.
Figure 2
- Before Use Illustration
Remove shipping plug and replace with air vent
plug (included) before initial use.
Pull stem upward before use, press down when
moving or storing pump .
B
C
Pull spring loaded lock pin, pivot torward
rear of
pump
to avoid scratching pump piston.
A
• Study, understand, and follow all instructions provided with and on this device before use.
• Do not exceed rated capacity.
• Burst hazard exists if hose or connection pressure exceeds rated pressure.
• Use gauge or other load measuring instrument to verify load.
• Always inspect hoses and connections for damage prior to use.
• Always wear protective clothing and eye protection when operating this equipment.
• Always ensure that the chosen application is stable to work on and around.
• Do not work under a lifted load without adequately rated support devices such as jack stands.
• This device is not suitable for use as support device!
• Do not subject the pump and its components to shock loads.
• Do not connect to application, which can return more oil to the reservoir than the pump reservoir can hold.
• Failure to heed these warnings may result in personal injury as well as property damage.
!
WARNING
Содержание B65122