DIP SWITCH SHOWN IN
PROGRAM MODE (ALL
SWITCHES CLOSED)
DIP SWITCH ON
TOUCHPAD
Q
UICK
P
ROGRAMMING
&
E
RASE
G
UIDE
N
O
.
2550
P
OWR
-T
OUCH
®
II
C
ONTROL
S
YSTEM
This guide assists individuals who are familiar with the Powr-Touch
®
II system. It provides a quick reference for all steps required to
program the relay panels, and to erase device assignments. For more detailed information, please refer to the primary Installation,
Operation & Maintenance Manual.
Before beginning any programming, you must be able to identify what equipment is connected to which relay set. Refer to the
gymnasium floor plan or the Custom Equipment Legend for device number assignment. Relay Set Terminal Assignment Worksheets
illustrating the relay panels are included with each relay panel – they are to be filled in by the electrician to annotate the equipment
number assignments (an example is shown on page 3).
Programming Guide
For systems with more than one TouchPad, programming can be done from any TouchPad in the system.
Note – While programming, you do not have to enter the password to activate the system.
Set the TouchPad to Address 0 (Program mode) by pushing all three dip switches on the back of the
TouchPad to the closed position. See detail at right.
Each piece of equipment is programmed at the TouchPad with the same sequence:
1.
Tell the system which Relay Set you are programming (
001
through
128
).
2.
Tell the system what type of equipment is to be operated (
Backstops, Curtains, MISC.
).
3.
Tell the system the pre-assigned number of the Device being controlled (
01
through
99
).
4.
Press the
DOWN / Off
button.
If the programming sequence has been performed properly, the TouchPad LED will illuminate
red
for half a second. After
programming is complete, the TouchPad dip switch must be reset to its previous valid address (1 thru 7).
Note – When punching in the Relay Set number, you must enter it as a three-digit number (
001
, not
1
). When punching in the Device
number, you must enter it as a two-digit number (
01
, not
1
).
Suggestion – With the TouchPad set to Program mode, it will be easier to program all equipment in succession. After all
programming has been completed, all equipment can then be tested in succession.
If programming cannot be performed successfully, double-check the following:
Verify all relay panel address settings (see chart on page 14 of the manual). Verify that one panel is set to Address 0. This panel
is the Master panel – one Master panel must be present in the system.
Verify that the four communication wires are present between each touchpad and a relay panel. Also verify that the ends of each
wire are connected to matching terminals: +12V, GND, COMM+, COMM–. See wiring diagram on page 16 or 17 of the manual.
Continue to pages 2 and 3 for additional programming notes.
INST 00387 084
2004 PORTER ATHLETIC EQUIPMENT COMPANY. ALL RIGHTS RESERVED.
8-1-2004
KEY PAD ON TOUCHPAD
Step 2: Press to select
type of equipment
Back-
stops
3
1
2
Use numbered keys to:
Step 1: Enter Relay Set number
Step 3: Enter Device number
AUX.
On
UP
MISC.
7
0
Off
DOWN
8
9
4
Curtains
6
5
Step 4: Press to