background image

6- ENG

D25798

D25798

Dried material is clog-
ging side-port “A” and
causing side-port “B”
to blow spray towards
the clogged side

A.

Soak side-ports in thinner to
clean clog. 

DO NOT 

poke any

opening with hard objects.

B.

Dried material at fluid
nozzle “C” restricts air
flow

Loose air nozzle
Air pressure set too
high

Remove air nozzle.  Wipe off fluid
tip using a cloth soaked in thinner
or by soft brush

Fasten nozzle securely
Reduce air pressure

C. Spitting, 

irregular

or fluttering spray

Fluid nozzle cracked or worn
Leak at thread of fluid nozzle
Leak at fluid needle

Needle packing worn out
Insufficient fluid in cup
Vent hole in container cover
clogged

Tighten or replace
Tighten fluid nozzle
Tighten compression nut
assembly or replace needle
packing
Replace packing
Fill cup with fluid
Clean Out

D.

Split spray pattern

Air pressure too high

Turn pattern control knob
clockwise to decrease fan width.
Turn fluid needle adjusting nut
counterclockwise to increase fluid
flow

Material too heavy

Insufficient air pressure

Fluid pressure too high
Dried material on tip of fluid noz-
zle or air jets of air cap

Thin material or use larger orifice
fluid nozzle set

Increase pressure to within limit

Reduce pressure

Clean

Air needle partially closed
Dried material in air jets or air cap
Obstruction in air line

Remove obstruction
Reduce air pressure and/or open
fluid control knob

Air pressure to high for viscosity
of fluid

Loose cup or foreign substances
on/between cup thread and fluid
inlet

Tighten and clean or replace it

F.

Inadequate air de-
livery

E.

Unatomized or
spattered spray

G. Excessive 

fog

I.

Material leaking
from nozzle when
trigger is released

H.

Material leaking
from fluid inlet of
cup.

Worn fluid needle
Dried material in tip of nozzle
Loose packing nut

Replace
Clean
Tighten needle packing nut by
turning counterclockwise

Defective Pattern

Likely Cause

Suggested Remedy

TROUBLESHOOTING

Open control knob
Clean

NOTICE:

See parts list to identify parts referred to in these Troubleshooting steps.

Содержание PSH1

Страница 1: ...la ESPAÑOL PÁGINA 9 FRANÇAIS PAGE 17 Copyright 2003 Porter Cable Corporation Instruction manual Manual de Instrucciones Manuel d instructions MODEL PSH1 MODÈLE PSH1 MODELO PSH1 To learn more about Porter Cable visit our website at http www porter cable com Pour de plus amples renseignements concernant Porter Cable consultez notre site Web à l adresse suivante http www porter cable com Para obtener...

Страница 2: ...and PREVENTING EQUIPMENT PROBLEMS To help you recognize this informa tion we use the symbols below Please read the manual and pay attention to these sections IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE READ AND UN DERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT HAZARD WHAT COULD HAPPEN HOW TO PREVENT IT Risk of e...

Страница 3: ...IT Risk of injection Certain parts are under pressure whenever the gun is connected to a pressurized air line These parts may be propelled if the gun is disassembled Disconnect the gun from the air line or completely depressurize the air line whenever the gun is to be disassembled Compressed air may propel dirt metal shavings etc and possibly cause an injury Never point any nozzle or sprayer towar...

Страница 4: ...y is governed by B pattern adjustment knob Turn knob counter clockwise to increase or clockwise to decrease air flow c Air quantity is controlled by C air volume control knob Turn knob counterclockwise to increase or clockwise to decrease the air flow NOTE Care should be exercised when handling spray gun to avoid damage to the orifice of the air cap and tip of fluid nozzle Damage to these parts re...

Страница 5: ...ze trigger to prevent dam age of fluid needle tip when unscrewing nozzle Lubrication Lubrication procedures must be observed after thoroughly cleaning the gun to ensure effective high quality performance of spray gun 1 Lubricate working points with straight mineral oil or castor oil 2 Periodically place a few drops of oil on tapered sections of fluid nozzle to ensure easy op eration of air cap Whe...

Страница 6: ... fluid needle adjusting nut counterclockwise to increase fluid flow Material too heavy Insufficient air pressure Fluid pressure too high Dried material on tip of fluid noz zle or air jets of air cap Thin material or use larger orifice fluid nozzle set Increase pressure to within limit Reduce pressure Clean Air needle partially closed Dried material in air jets or air cap Obstruction in air line Re...

Страница 7: ...ly D25167 16 Teflon Ring D25168 17 O Ring D25169 18 Spring D25170 19 Spray Nut Assembly D25171 20 E Ring D25172 21 Spray Regulating Nut D25173 22 O Ring D25174 23 Spray Regulating Screw D25175 24 Gasket D25176 25 Control Knob D25177 26 Paint Needle Complete D25178 27 Spring for Paint Needle D25179 28 Lock to Fluid Control Knob D25180 29 Fluid Control Knob D25181 30 Trigger D25182 31 Trigger Pin D2...

Страница 8: ...ompressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service call arrangements If the purchaser does not receive satisfactory results from the Porter Cable Authorized Warranty Service Center the purchaser should contact Porter Cable THIS WARRANTY DOES NOT COVE...

Отзывы: