9- ENG

D25802

BASIC ELEMENTS OF ENGINE

Refer to the engine manual for location and operation of engine controls.

Choke Control:

Opens and closes carburetor choke valve 

Throttle Control Lever:

Controls engine speed. 

Starter Grip:

Pulling starter grip operates recoil starter to crank engine.

Fuel Valve Lever

: Opens / closes connection between fuel tank and carburetor.

Engine Switch:

Enables and disables ignition system pressure washer operating

features

PRESSURE WASHER TERMINOLOGY

PSI:

Pounds per Square Inch. The unit of measure for water pressure. Also used

for air pressure, hydraulic pressure, etc.

GPM:

Gallons Per Minute. The unit of measure for the flow rate of water through

the pressure washer.

CU: 

Cleaning Units. GPM multiplied by PSI.

Bypass Mode: 

In Bypass Mode, the pump is recirculating water because the

trigger of the spray gun is not pulled. If unit is left in bypass mode for more than
two (2) minutes, the water temperature can rise to a dangerous level and may
damage internal components of the pump. Any damage to pump due to these
causes will not be covered under warranty. 

DO NOT allow your unit to operate in bypass mode for more
than two minutes at any time.  Overheating of pump can

cause damage to pump.

Thermal Relief Valve: 

In an effort to prevent extreme damage, pumps are

equipped with a thermal relief valve. This valve will open when the temperature
inside the pump rises too high. This valve will then release a gush of water in an
effort to lower the temperature inside the pump. Immediately after this occurs,
the valve will close. The thermal relief valve is part of the pump and is not visible
to the user.

Chemical Injection:

Feeds cleaning agents into the pump to mix with the

pressurized water and help in cleaning.

Water Supply:

All pressure washers must have a source of water. The minimum

requirements for a water supply are 20 PSI and 5 gallons per minute. 

PRESSURE WASHER OPERATING FEATURES

PRESSURE ADJUSTMENTS

The pressure setting is preset at the factory to achieve optimum pressure and
cleaning. If you need to lower the pressure, it can be accomplished by these 
methods. 

1.  Back away from the surface to be cleaned.

The further away you are, the

less the pressure will be on the surface to be cleaned.

DO NOT attempt to increase pump pressure. A higher pressure
setting than the factory set pressure may damage pump.

2.

Change to a wider spray pattern nozzle.

See How to Use Wand

paragraph in this section.

Содержание PCV2250

Страница 1: ...se instructions before starting operations Part No D25802 025 1 ESPAÑOL PÁGINA 21 FRANÇAIS PAGE 41 To learn more about Porter Cable visit our website at http www porter cable com PCV2250 Copyright 2002 Porter Cable Corporation The Model and Serial No plate is located on the frame Record these numbers in the spaces below and retain for future reference Model No Type Serial No ...

Страница 2: ...quality product from America s leading manufacturer of pressure washers This pressure washer when properly used and maintained will provide trouble free service Please read and follow these instructions for proper use and maintenance All sales of pressure washers are final Do not return this product to the retailer Call 1 888 559 8550 If you experience any problems and need assistance please call ...

Страница 3: ...o the tank Use care in filling tank to avoid spilling fuel Move pressure washer away from fueling area before starting engine Heat will expand fuel in the tank which could result in spillage and possible fire explosion Keep maximum fuel level below top of tank to allow for expansion Operating the pressure washer in an explosive environment could result in a fire Operate and fuel equipment in well ...

Страница 4: ...ssure washer from vehicle immediately upon arrival at your destination Your washer operates at fluid pressures and velocities high enough to penetrate human and animal flesh which could result in amputation or other serious injury Leaks caused by loose fittings or worn or damaged hoses can result in injection injuries DO NOT TREAT FLUID INJECTION AS A SIMPLE CUT See a physician immediately Never p...

Страница 5: ...ressure Pull starter cord slowly until resistance is felt Then pull cord rapidly to avoid kickback and prevent hand or arm injury The spray gun wand is a powerful cleaning tool that could look like a toy to a child Keep children away from the pressure washer at all times Contact with hot surfaces such as engines exhaust components could result in serious burn During operation touch only the contro...

Страница 6: ...iping and trim and delicate objects such as flowers and shrubs Before spraying check the item to be cleaned to assure yourself that it is strong enough to resist damage from the force of the spray Avoid the use of the concentrated spray stream except for very strong surfaces like concrete and steel Operating without flow of water will result in equipment damage Operating the pressure wash er with ...

Страница 7: ... frame and connect handle to frame 4 Assemble grommet kit and quick connect nozzles as described in instructions supplied 5 Add engine oil supplied to engine Refer to engine manual supplied by engine manufacturer for correct procedure NOTE There will be a slight amount of oil in the engine from factory testing ASSEMBLY INSTRUCTIONS ...

Страница 8: ...y change out high pressure nozzles for different spray patterns and change to the soap nozzle for low pressure and chemical soap applications See Operation section Chemical Hose not shown Allows cleaners or cleaning solvents to be mixed with the pressurized water stream See How To Siphon Chemicals Cleaning Solvents in Operation section of this manual READ THIS OWNER S MANUAL AND SAFETY RULES BEFOR...

Страница 9: ...e in bypass mode for more than two minutes at any time Overheating of pump can cause damage to pump Thermal Relief Valve In an effort to prevent extreme damage pumps are equipped with a thermal relief valve This valve will open when the temperature inside the pump rises too high This valve will then release a gush of water in an effort to lower the temperature inside the pump Immediately after thi...

Страница 10: ...l quick connect coupler back and insert nozzle 2 Release quick connect coupler and twist nozzle to make sure it is secure in coupler Risk Of Injury Ensure nozzle is completely inserted in QC socket and QC snap ring is fully engaged forward before squeezing gun trigger 0º nozzle Red This nozzle delivers a pinpoint stream and is extremely powerful It covers a very small area of cleaning This nozzle ...

Страница 11: ...netrate human and animal flesh which could result in amputation or other serious injury Leaks caused by loose fittings or worn or damaged hoses can result in injection injuries DO NOT TREAT FLUID INJECTION AS A SIMPLE CUT See a physician immediately Never fill fuel tank when engine is running or hot Do not smoke when filling fuel tank Never fill fuel tank completely Fill tank to 1 2 below bottom o...

Страница 12: ...ection of this manual 7 Turn water source on NOTE Make sure water supply is turned on 8 Start engine See Engine operators Manual for correct procedure NOTE If the engine does not start after two pulls pull the trigger to relieve the pressure 9 Depress trigger on gun to start water flow NOTE Stand on a stable surface and grip gun wand firmly with both hands Expect the gun to kick when triggered 10 ...

Страница 13: ...turer s recommendations for any and all maintenance MAINTENANCE WAND If the nozzle becomes clogged with foreign materials such as dirt excessive pressure may develop If the nozzle becomes partially clogged or restricted the pump pressure will pulsate Clean the nozzle immediately using the nozzle kit supplied and the following instructions 1 Shut off the pressure washer and turn off the water suppl...

Страница 14: ...ould be checked periodically and cleaned if necessary 1 Remove filter by grasping end and removing it from water inlet of pump as shown 2 Clean filter by flushing it with water on both sides 3 Re insert filter into water inlet of pump NOTE Cone side faces out Filter Screen ...

Страница 15: ...roximately 12 inches of garden hose with a male hose connector attached to one end Use only RV antifreeze Any other antifreeze is corrosive and can damage pump 2 Disconnect spark plug wire 3 Disconnect high pressure hose from pump and from spray gun 4 Connect 12 inch length of hose to water inlet of pump 5 Add RV antifreeze to hose as shown 6 Pull engine starter rope slowly several times until ant...

Страница 16: ...gh pressure See How to Use Wand paragraph in the Operation Section Low water supply Water supply must be at least 5 GPM 20 PSI Leak at high pressure hose Repair leak Apply sealant tape if necessary Nozzle obstructed Clean nozzle with paper clip or nozzle cleaning tool pour water into nozzle end to flush out ob struction Water filter screen clogged Remove and clean filter Defective E Z start valve ...

Страница 17: ...ssure hose Chemical build up in chemical injector Have parts cleaned or replaced by AWSC Worn seal or packing Have replaced by AWSC Worn or obstructed valves Have replaced by AWSC Worn unloader piston Have replaced by AWSC Worn E Z start valve Check and replace Loose hose connection Loose connections Tighten Piston packings worn Have replaced by AWSC Worn or broken o rings Have replaced by AWSC Pu...

Страница 18: ...ressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service call arrangements If the purchaser does not receive satisfactory results from the Porter Cable Authorized Warranty Service Center the purchaser should contact Porter Cable THIS WARRANTY DOES NOT COVER M...

Страница 19: ...19 ENG D25802 NOTES ...

Страница 20: ...hon RV antifreeze into pump for cold weather storage or long term storage Never leave unit running for more than 2 minutes without pulling gun trigger doing so will destroy pump and void warranty Pump is equipped with a thermal relief valve If the water overheats this valve will open and allow a gush of water to escape Once the water is released the valve closes allowing the pump to operate normal...

Отзывы: