22- ENG

A01787

Regulator will
not shut off air
outlet.

Damaged regulator.

Replace.

PROBLEM

CAUSE

CORRECTION

Motor will not
run.

Fuse blown, circuit breaker
tripped.

1. Check fuse box for blown

fuse and replace as
necessary. Reset circuit
breaker. Do not use a fuse
or circuit breaker with
higher rating than that
specified for your particular
branch circuit.

2. Check for proper fuse. You

should use a time delay
fuse.

3. Check for low voltage

conditions and/or proper
extension cord.

4. Disconnect the other

electrical appliances from
circuit or operate the
compressor on its own
branch circuit.

Motor overload protection
switch has tripped.

Let motor cool off and
overload switch will
automatically reset.

Tank pressure exceeds
pressure switch "cut-in"
pressure.

Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.

Extension cord is wrong
length or gauge.

Check for proper gauge wire
and cord length.

Loose electrical connections. Check wiring connection

inside pressure switch and
terminal box area.

Have checked by a Trained
Service Technician.

Check valve stuck open.

Remove and clean, or
replace.

Possible defective motor or
starting capacitor.

Have checked by a Trained
Service Technician.  Do not
operate the compressor in
the paint spray area.  See
flammable vapor warning.

Paint spray on internal motor
parts.

Bleed the line by pushing the
lever on the pressure switch
to the "off" position; if the
valve does not open, replace
switch.

Pressure release valve on
pressure switch has not
unloaded head pressure.

Содержание JOB BOSS CFFC350B

Страница 1: ...efore starting operations Part No A01787 0312 0 ESPA OL P GINA 25 FRAN AIS PAGE 49 To learn more about Porter Cable visit our website at http www porter cable com Copyright 2001 Porter Cable Corporati...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...pressure in the air tank begins to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high pressure...

Страница 9: ...before each use Do not use if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the instal...

Страница 10: ...OT USE 14 OR 16 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit...

Страница 11: ...ank pressure Tank Pressure Gauge E The tank pressure gauge indicates the reserve air pressure in the tank Regulator F Controls the air pressure shown on the outlet pressure gauge Pull the knob out and...

Страница 12: ...ways be clean and ventilation openings free from obstructions See Maintenance Check Valve L When the air compressor is operating the check valve is open allowing compressed air to enter the air tank W...

Страница 13: ...tank during the break in period 4 Move the On Auto Off lever to ON AUTO position The compressor will start 5 Run the compressor for 15 minutes Make sure the drain valve is open and there is minimal ai...

Страница 14: ...he console brackets d or be temporarily mounted using the mounting hole c Can cause serious injury or death Tank may contain 150 PSI of air pressure Never connect accessories to unregulated air Never...

Страница 15: ...carrying handle a to lift unit 2 Slide handle b out until it locks into place 3 Pull unit as shown do not push unit NOTE When transporting do not lift the unit to the point where it would tip over bac...

Страница 16: ...operation and the working environment Compressor outfits in an extremely dirty and or hostile environment will require a greater frequency of all maintenance checks Unit cycles automatically when powe...

Страница 17: ...from filter cover 3 Place new air filter into filter cover Refer to the Repair Parts for the correct part number 4 Replace air filter cover and lock into place To Drain Tank 1 Set the On Auto Off lev...

Страница 18: ...ch holds the valve disc in the closed position If not the check valve needs to be cleaned or replaced 8 Clean or replace the check valve A solvent such as paint or varnish remover can be used to clean...

Страница 19: ...y 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the air tank ca...

Страница 20: ...ttings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pressure switch release va...

Страница 21: ...essor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air...

Страница 22: ...ch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wro...

Страница 23: ...23 ENG A01787 NOTES...

Страница 24: ...essors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service cal...

Отзывы: