background image

Instruction

manual

IMPORTANT

Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.

Part No. D28469-032-0

ESPAÑOL: PÁGINA 29
FRANÇAIS: PAGE 57

To learn more about Porter-Cable 

visit our website at: 

http://www.porter-cable.com

Model

H1000IS

Copyright © 2003 Porter-Cable Corporation

The Model and Serial No. plate is located on the frame.
Record these numbers in the spaces below and retain for
future reference.

Model No. 

Type

Serial No. 

Generator

Содержание H1000IS

Страница 1: ...operations Part No D28469 032 0 ESPA OL P GINA 29 FRAN AIS PAGE 57 To learn more about Porter Cable visit our website at http www porter cable com Model H1000IS Copyright 2003 Porter Cable Corporation...

Страница 2: ...f not avoided will result in death or serious injury indicates a potentially hazardous situation which if not avoided could result in death or serious injury indicates a potentially hazardous situatio...

Страница 3: ...rdsets could prevent operation of circuit breakers and result in electrical shock Always use a cordset having a grounding wire with an appropriate grounding plug DO NOT use an ungrounded plug Use prop...

Страница 4: ...gasoline or gasoline vapors to ignite Turn engine off and allow it to cool before adding fuel to the tank Equip area of operation with a fire extinguisher certified to handle gasoline or fuel fires Ad...

Страница 5: ...lt Fuel or oil leaks will damage carpet paint or other surfaces in vehicles or trailers If generator is equipped with a fuel shut off valve turn the valve to the off position before transporting to av...

Страница 6: ...Any gasoline operated household generator will incur voltage variations causing damage to voltage sensitive ap pliances or could result in fire Always use a U L listed voltage sensitive surge protect...

Страница 7: ...VENT IT HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT RISK OF MOVING PARTS Never operate generator with guarding or cover plates removed Avoid wearing loose fitting clothing or jewelry which could be caugh...

Страница 8: ...d our many Authorized Warranty Service Centers are conveniently located and equipped to handle all in warranty and out of warranty service For the location of the nearest Authorized Warranty Service C...

Страница 9: ...he parts carton and set aside for later use 2 Cut wire ties holding generator to pallet and remove protective wrapping 3 Remove all packaging leaving generator on pallet IMPORTANT DO NOT remove genera...

Страница 10: ...2 Place handle grips on handle assemblies 3 Place one 5 8 washer into the bottom of each end cap Push end caps onto the end of the handle assemblies 4 Attach handle assemblies to frame using four scr...

Страница 11: ...placed under frame with hole facing outward 9 Using a hammer tap axle cap onto end of axle without the hole 10 Slide wheel onto axle with valve stem to the outside 11 Slide spacer onto axle against w...

Страница 12: ...er brackets 4 Bolts 5 16 18 x 7 8 4 Lockwashers 5 16 4 Nuts Whizlock 5 16 1 Close fuel shut off valve on tank by turning clockwise until it stops 2 Remove four screws and washers securing fuel tank to...

Страница 13: ...label NOTE Bracket should not overlap onto weld a Failure to properly position skyhook can cause property damage serious injury or death and void the manufacturer s warranty 10 Torque four bolts to 11...

Страница 14: ...acid can cause an explosion To prevent explosive fumes from accumulating do not charge in an enclosed area Sulfuric acid is a flammable and explosive chemical that is harmful to the skin eyes and clot...

Страница 15: ...d be installed by a licensed electrician and in com pliance with all state and local electrical codes When installing a Double Throw Transfer Switch a minimum of 10 gauge wiring must be used The elect...

Страница 16: ...OW OIL SHUTDOWN Your generator engine is equipped with Low Oil Shutdown Low Oil Shutdown is a safety device designed to protect your engine from damage in the event the oil level in the crankcase is l...

Страница 17: ...ive 12V DC cable to the generators positive 12V DC outlet 3 Connect the black negative 12V DC cable to the battery s negative terminal 4 Attach the other end of the black negative 12V DC cable to the...

Страница 18: ...equipment 2 Connect inductive load equipment first inductive loads consist of refrigerators freezers water pumps air conditioners or small hand tools Connect the items that require the most wattage f...

Страница 19: ...serves the right to inspect the electrical connections at the customer s site of operation and test the generator for proper opera tion before any determination of liability is made Failure to maintai...

Страница 20: ...GENERATOR MAINTENANCE Your generator should be kept clean and dry at all times The generator should not be stored or operated in environments that includes excessive moisture dust or any corrosive va...

Страница 21: ...Add one teaspoon of oil through the spark plug hole 6 Place rag over spark plug hole and pull the recoil a few times to lubricate the combustion chamber 7 Replace the spark plug but do not connect the...

Страница 22: ...iguring your total wattage to be used C Always start your largest electric motor first and then plug in other items one at a time NOTE On 120 volt loads the maximum starting wattage should NOT exceed...

Страница 23: ...was calculated by 2 to 4 times to assure adequate generator capacity If the nameplate information is not available use the values on the following chart as a guide 3 Remember that the starting and run...

Страница 24: ...TARTING INDUCTIVE LOADS RUN WATTS TIMES X START FACTOR DO NOT CONNECT VOLTAGE SENSITIVE ELECTRONIC EQUIPMENT TV SET COMPUTER ETC DIRECTLY TO YOUR GENERATOR IF YOU USE THE GENERATOR TO POWER SENSITIVE...

Страница 25: ...nd reset 7 Spark plug wire loose 7 Attach wire to spark plug No electrical output 1 Overload 1 Reduce load 2 Faulty cords or equipment 2 Check for damaged bare or frayed wires on equipment Replace Rep...

Страница 26: ...essors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service cal...

Страница 27: ...27 ENG D28469 NOTES...

Страница 28: ...et settings and damage anything connected to the generator Be sure a volt amp surge protector is used when sensitive electronic equipment is used such as televisions computers stereos and etc The dama...