Porter-Cable FCP350 Скачать руководство пользователя страница 6

6

EMPLOYER’S RESPONSIBILITIES

DANGER: Employer must enforce compliance with the safety warnings

and all other instructions contained in this manual.

Keep this manual available for use by all people assigned to use this tool.

For personal safety and proper operation of this tool, read and understand
tool labels and manual. Failure to follow warnings could result in DEATH or
SERIOUS INJURY. Read and follow all of these instructions carefully.

FUNCTIONAL DESCRIPTION

FOREWORD

Porter-Cable Model FCP350 is a high pressure heavy duty pneumatic
framing nailer. It is designed to install 30 - 34 degree clipped head paper
tape collated framing nails .113" - .131" dia. of various lengths from 2" to
3

1

/

2

" long. 

WARNING: Use approved Porter-Cable fasteners only.

POWER SOURCE

This tool is designed to operate on clean, dry, compressed air at regulated
pressures between 80 and 150 PSI (Pounds per Square Inch)(5.5 to 10.3
BAR). The preferred system would include a filter, a pressure regulator, and an
automatic oiler located as close to the tool as possible, within 15 ft/4.6 m is
ideal.

All compressed air contains moisture and other contaminates that are
detrimental to internal components of the tool. An air line filter will remove
most of these contaminates and significantly prolong the life of the tool. If an
in-line oiler is not available: place five or six drops of Porter-Cable Air Tool Oil
into the tool’s air inlet at the beginning of each workday.

The tool is equipped with a 

3

/

8

" male "quick connector”. A 

3

/

8

" supply line (and

fittings) are required for maximum tool performance. The tool must always be
connected to the air supply with a coupling such that all pressure is removed
from the tool when the coupling is disconnected.

DANGER: All air line components (hoses, connectors, filters, regulators,
etc.) must have a minimum working pressure rating of at least 300 PSI
(20.7 BAR) or 150% of maximum system potential, whichever is
greater.

Do not connect tool to pressure which potentially exceeds 200 PSI

(13.7 BAR).

Only connect tool to air supply hose with a coupling that

automatically removes all pressure from the tool when the coupling
is disconnected.

Disconnect tool from air supply before performing maintenance,

clearing a jammed fastener, leaving work area, moving tool to
another location, or handing the tool to another person.

TECHNICAL SPECIFICATIONS

Noise level

 . . . . . . . . . . . . . . . . . .

Typical Mean 

A - Weighted sound impulse

 . . .

effective Acceleration  . . . . 4.9 m/s

2

power level  . . . . . . 105 dBA

P - Emission sound pressure

pressure level . . . . . . 98 dBA

906388 - 10-28-02.qxd  10/28/02  11:50 AM  Page 6

Содержание FCP350

Страница 1: ..._______________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instr...

Страница 2: ...in conformity with the regulations EN292 2 section 3 of 1992 EN292 1 section 5 of 1992 EN1050 1993 EN792 13 2000 E ESPANOL DECLARACION DE CONFORMIDAD CE Declaramos bajo nuestra sola responsabilidad q...

Страница 3: ...tool labels and manual Failure to follow warnings could result in DEATH or SERIOUS INJURY Fig 1 2 Operator and others in work area MUST wear safety glasses with side shields These safety glasses must...

Страница 4: ...amaged Do not alter or remove safety trigger or springs Make daily inspections for free movement of trigger and safety mechanism Fig 8 15 Do not use tool without safety warning label If label is missi...

Страница 5: ...other fasteners or with the tool at too steep an angle the fasteners can ricochet causing personal injury Fig 15 26 Do not drive fasteners close to the edge of the workpiece The workpiece is likely to...

Страница 6: ...of the tool An air line filter will remove most of these contaminates and significantly prolong the life of the tool If an in line oiler is not available place five or six drops of Porter Cable Air T...

Страница 7: ...es repair 2 Orient a strip of approved fasteners with points down A Fig 19 align and insert into the magazine T slot points first DANGER Do not load fastener strip into magazine backwards 3 Observe fa...

Страница 8: ...ion nose of tool onto work surface depress safety and squeeze trigger to fire a fastener Allow tool to recoil away from work surface as fastener is driven This single sequential actuation method provi...

Страница 9: ...ted to a nominal setting Test fire a fastener and check depth If a change is desired rotate the adjustment knob A Fig 25 The adjustment knob has detents every 1 4 turn Rotate the knob A Fig 25 clockwi...

Страница 10: ...fasteners to the rear and remove from magazine see Fig 22 3 Use a pair of needle nose pliers and or a flat screwdriver to free bent fastener from back of nosepiece A Fig 30 If fastener cannot be remo...

Страница 11: ...against defective material and workmanship We cannot guarantee repairs made or attempted by anyone other than these agencies Should you have any questions about your tool feel free to write us at any...

Страница 12: ...ease write to PORTER CABLE CORPORATION 4825 Highway 45 North Jackson Tennessee 38305 Attention Product Service THE FOREGOING OBLIGATION IS PORTER CABLE S SOLE LIABILITY UNDER THIS OR ANY IMPLIED WARRA...

Страница 13: ...r obtenir de l aide pour en rep rer un Pour obtenir des pi ces et accessoires pour les produits Porter Cable Delta s adresser tout distributeur Porter Cable Delta centre de service agr ou centre de se...

Отзывы: