TROUBLESHOOTING
CAUTION:
Disconnect tool from air supply before performing any
Service Procedure.
SYMPTOM PROBLEMS
SOLUTIONS
1. Air leak near top of
Loose screws.
Tighten screws.
tool or in trigger area.
Worn or damaged
Install “OVERHAUL” Maintenance Kit.
o-rings or seals.
2. Tool does nothing or
Inadequate air supply.
Verify adequate air supply.
operates sluggishly.
Inadequate lubrication.
Put 10 to 15 drops of oil into air inlet.
Worn or damaged
Install “DRIVER” Maintenance Kit.
o-rings or seals.
Install “OVERHAUL” Maintenance Kit.
3. Air leak near bottom
Loose screws.
Tighten screws.
of tool.
Worn or damaged
Install “OVERHAUL” Maintenance Kit.
o-rings or bumper.
4. Tool jams frequently.
Incorrect fasteners.
Verify approved fasteners of
correct size.
Damaged fasteners.
Replace w/undamaged fasteners.
Magazine or nose
Tighten screws.
screws loose.
Magazine is dirty.
Clean magazine.
Pusher spring damaged.
Replace spring.
Driver is worn or damaged.
Install “DRIVER” Maintenance Kit.
5. Other.
Contact a Porter-Cable
Service Facility.