background image

Instruction

manual

IMPORTANT

Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.

Part No. D27243-028-0

ESPAÑOL: PÁGINA 23
FRANÇAIS: PAGE 45

To learn more about Porter-Cable 

visit our website at: 

http://www.porter-cable.com

Model

H451CS

Copyright © 2002 Porter-Cable Corporation

The Model and Serial No. plate is located on the frame.
Record these numbers in the spaces below and retain for
future reference.

Model No. 

Type

Serial No. 

Generator

Содержание D27243-028-0

Страница 1: ...operations Part No D27243 028 0 ESPA OL P GINA 23 FRAN AIS PAGE 45 To learn more about Porter Cable visit our website at http www porter cable com Model H451CS Copyright 2002 Porter Cable Corporation...

Страница 2: ...o cause cancer birth defects or other reproductive harm CONSUMER GENERAL AND SERVICE INFORMATION Please read and follow these instructions for proper use and maintenance If you experience any problems...

Страница 3: ...warnings and operating instructions before using RISK OF ELECTROCUTION AND FIRE HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT Attempting to connect generator directly to the electrical system of any build...

Страница 4: ...harged components can transmit electricity to the frame and other surfaces resulting in electrical shock to anyone con tacting them Operate generator in a clean dry well ventilated area Make sure hand...

Страница 5: ...PERATE UNIT INDOORS OR IN ANY CONFINED AREA Materials placed against or near the generator or operating the generator in areas where the temperature exceeds 104 F am bient such as storage rooms or gar...

Страница 6: ...sed areas such as garages basements storage sheds or in any location occupied by humans or animals Keep children pets and others away from area of operat ing unit Gasoline engines produce toxic carbon...

Страница 7: ...surge protector Raising or suspending generators equipped with lift rings improperly Generator could fall causing serious injury or death to you or others Always use proper connecting procedures as de...

Страница 8: ...vered by guarding to prevent injury Contact with moving parts can result in serious injury RISK FROM LIFTING The generator is too heavy to be lifted by one person Obtain as sistance from others before...

Страница 9: ...sed in accordance with appropriate local electrical code regulations Refer to instructions enclosed with each plug for proper installation 3 12V DC cables to be used with the 12V DC outlets See Operat...

Страница 10: ...ck into the utility company s system causing possible electrocution of workers who are repairing the electrical lines To avoid back feeding of electricity into utility systems a double throw transfer...

Страница 11: ...the Low Oil Protection will prevent the engine from restarting until sufficient oil has been added NOTE The Low Oil Protection mechanism is very sensitive You must fill the engine to the full mark on...

Страница 12: ...s Manual for correct grade and quantity of oil 2 Check fuel level fill as required Make sure generator is turned off and has been allowed time to cool down Use clean fresh regular unleaded gasoline w...

Страница 13: ...sition on warm engine starts 4 Move the ON OFF switch on engine to the ON position 5 Grasp handle on rope starter and pull slowly until resistance is felt Let the rope rewind slowly Pull rope with a r...

Страница 14: ...he warranty on your generator Follow the wattage calculation table in the Wattage Calculation section of this manual Overloading the generator will cause power fluctuations and can damage equipment an...

Страница 15: ...The warranty of the generator does not cover items that have been subjected to operator abuse or negligence To receive full value from the warranty operator must maintain the generator as instructed i...

Страница 16: ...adding stabilizer to allow it to enter the fuel system 3 Next shut off engine 4 Disconnect the spark plug wire and remove the spark plug 5 Add one teaspoon of oil through the spark plug hole 6 Place...

Страница 17: ...half of the rated generator wattage Example a 5000 rated wattage generator 2500 maximum starting wattage IMPORTANT DETERMINING WATTAGE REQUIREMENTS Before operating this generator list all of the appl...

Страница 18: ...a 100 watt light bulb requires only 100 watts to start Most resistive loads will be listed in wattage The wattage ratings shown are averages Wattage requirements may vary with different brands of appl...

Страница 19: ...TARTING INDUCTIVE LOADS RUN WATTS TIMES X START FACTOR DO NOT CONNECT VOLTAGE SENSITIVE ELECTRONIC EQUIPMENT TV SET COMPUTER ETC DIRECTLY TO YOUR GENERATOR IF YOU USE THE GENERATOR TO POWER SENSITIVE...

Страница 20: ...g No electrical output 1 Overload 1 Reduce load 2 Faulty cords or equipment 2 Check for damaged bare or frayed wires on equipment Replace Repeated circuit breaker tripping 1 Generator overloaded 1 Red...

Страница 21: ...essors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service cal...

Страница 22: ...et settings and damage anything connected to the generator Be sure a volt amp surge protector is used when sensitive electronic equipment is used such as televisions computers stereos and etc The dama...

Отзывы: