background image

12- ENG

D25805

STARTING

Prior to starting, refer to your engine manual for proper starting procedures
for your engine type.
1.

In a well ventilated outdoor area 

Add fresh high quality unleaded gasoline

with a pump octane rating of 86 or higher.  Do not overfill. Wipe up spilled
fuel before starting the engine. Refer to engine manual for correct procedure.

2.

Check engine oil level.

See Engine Operators Manual for correct procedure. 

NOTE: There will be a slight amount of oil in the engine from factory testing.
3.

Verify the filter screen

is in water inlet of pump. 

NOTE:

Cone side faces out.

4.

Connect

water source to pump inlet.

NOTE:

Water source must provide a minimum of 5

gallons per minute at 20 p.s.i. 

5.

Connect

high pressure hose to pump outlet.

6.

If applying a chemical or cleaning solution

, see How

To Siphon Chemicals/Cleaning Solvents in Operation
section of this manual.

7.

Turn water source on. NOTE:

Make sure water

supply is turned on.

8.

Start engine.

See Engine operators Manual for

correct procedure. 

NOTE: 

If the engine does not

start after two pulls, pull the trigger to relieve the
pressure. 

9.

Depress trigger on gun to start water flow. NOTE:
Stand on a stable surface

and grip gun/wand firmly

with both hands. Expect the gun to kick when
triggered.

10. Release trigger to stop water flow.
11. Adjust nozzle spray for the task

being performed or change quick connect

tip. See 

How To Use Wand

instructions in this section.

TO SHUT DOWN

IMPORTANT: Read and understand how to shut down the pressure washer
before operating.

1.

If you have siphoned chemicals, siphon a bucket of clean water through the
chemical hose.  

NOTE: 

Failure to do so will cause damage to the pump.

2.

Refer to engine manual for correct engine shut down procedure.

NOTE:  NEVER turn the water off with the engine running.

3.

Turn water source off.  

4.

Pull trigger on spray gun to relieve any water pressure in hose or spray gun.

5.

See Storage section in this manual for proper storage procedures.

Filter Screen

High Pressure Hose

Water
Source

Содержание D25805-025-1

Страница 1: ...No D25805 025 1 ESPA OL P GINA 21 FRAN AIS PAGE 41 To learn more about Porter Cable visit our website at http www porter cable com PCH3500C Copyright 2002 Porter Cable Corporation The Model and Seria...

Страница 2: ...ality product from America s leading manufacturer of pressure washers This pressure washer when properly used and maintained will provide trouble free service Please read and follow these instructions...

Страница 3: ...the tank Use care in filling tank to avoid spilling fuel Move pressure washer away from fueling area before starting engine Heat will expand fuel in the tank which could result in spillage and possib...

Страница 4: ...sure washer from vehicle immediately upon arrival at your destination Your washer operates at fluid pressures and velocities high enough to penetrate human and animal flesh which could result in amput...

Страница 5: ...essure Pull starter cord slowly until resistance is felt Then pull cord rapidly to avoid kickback and prevent hand or arm injury The spray gun wand is a powerful cleaning tool that could look like a t...

Страница 6: ...nt auto striping and trim and delicate objects such as flowers and shrubs Before spraying check the item to be cleaned to assure yourself that it is strong enough to resist damage from the force of th...

Страница 7: ...OTE There will be a slight amount of oil in the engine from factory testing NOTE The high pressure pump was filled with oil at the factory There is no need to add oil at this time see the Maintenance...

Страница 8: ...patterns and change to the soap nozzle for low pressure and chemical soap applications See Operation section Chemical Hose not shown Allows cleaners or cleaning solvents to be mixed with the pressuri...

Страница 9: ...ing agents into the pump to mix with the pressurized water and help in cleaning Water Supply All pressure washers must have a source of water The minimum requirements for a water supply are 20 PSI and...

Страница 10: ...e it is secure in coupler Risk Of Injury Ensure nozzle is completely inserted in QC socket and QC snap ring is fully engaged forward before squeezing gun trigger 0 nozzle Red This nozzle delivers a pi...

Страница 11: ...s injury Leaks caused by loose fittings or worn or damaged hoses can result in injection injuries DO NOT TREAT FLUID INJECTION AS A SIMPLE CUT See a physician immediately Never fill fuel tank when eng...

Страница 12: ...TE Make sure water supply is turned on 8 Start engine See Engine operators Manual for correct procedure NOTE If the engine does not start after two pulls pull the trigger to relieve the pressure 9 Dep...

Страница 13: ...ALL WATER PRESSURE THE ENGINE CONTAINS FLAMMABLE FUEL DO NOT SMOKE OR WORK NEAR OPEN FLAMES WHILE PERFORMING MAINTENANCE To ensure efficient operation and longer life of your pressure washer a routin...

Страница 14: ...l pulsate Clean the nozzle immediately using the nozzle kit supplied and the following instructions 1 Shut off the pressure washer and turn off the water supply 2 Disconnect spark plug wire 3 Pull tri...

Страница 15: ...with a male hose connector attached to one end Use only RV antifreeze Any other antifreeze is corrosive and can damage pump 2 Disconnect spark plug wire 3 Disconnect high pressure hose from pump and f...

Страница 16: ...pressure See How to Use Wand paragraph in the Operation Section Low water supply Water supply must be at least 5 GPM 20 PSI Leak at high pressure hose Repair leak Apply sealant tape if necessary Nozz...

Страница 17: ...iston Have replaced by AWSC Worn E Z start valve Check and replace Loose hose connection Loose connections Tighten Piston packings worn Have replaced by AWSC Worn or broken o rings Have replaced by AW...

Страница 18: ...essors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service cal...

Страница 19: ...19 ENG D25805 NOTES...

Страница 20: ...water overheats this valve will open and allow a gush of water to escape Once the water is released the valve closes allowing the pump to operate normally Don t allow hoses to contact the HOT engine m...

Отзывы: