Porter-Cable CPLMC7580V2C Скачать руководство пользователя страница 7

7- ENG

D24225

Model No.

CPLMC7580V2C

Horsepower

7.5

Voltage/Hertz/Phase

240/60/1

Minimum Branch Circuit Requirement

30 Amp

*Fuse Type

Time Delay

Air Tank Capacity (Gallon)

80  ASME, Vertical

Approximate Cut-in Pressure

145 PSIG

Approximate Cut-out Pressure

175 PSIG

SCFM @ 175 PSIG

23.5

Magnetic Starter

Included

SPECIFICATIONS

GLOSSARY

Become familiar with these terms before operating the unit.

CFM

:  Cubic feet per minute.

SCFM:

Standard cubic feet per minute; a unit of measure of air delivery.

PSIG:

Pounds per square inch gauge; a unit of measure of pressure.

Code Certification: 

Products that bear one or more of the following marks:

UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent
safety laboratories and meet the applicable Underwriters Laboratories
Standards for Safety.

Cut-In Pressure:

While the motor is off, air tank pressure drops as you

continue to use your accessory. When the tank pressure drops to a certain low
level the motor will restart automatically.  The low pressure at which the motor
automatically restarts is called "cut-in" pressure.

Cut-Out Pressure:

When an air compressor is turned on and begins to run,

air pressure in the air tank begins to build.  It builds to a certain high pressure
before the motor automatically shuts off - protecting your air tank from
pressure higher than its capacity.  The high pressure at which the motor shuts
off is called "cut-out" pressure.

Branch Circuit: 

Circuit carrying electricity from electrical panel to outlet.

DUTY CYCLE

Air compressors should be operated on not more than a 50% duty cycle. This
means an air compressor that pumps air more than 50% of one hour is
considered misuse, because the air compressor is undersized for the required
air demand.  Maximum compressor pumping time per hour is 30 minutes.

Accessories for this unit are available at the store the unit was purchased.

ACCESSORIES

* A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same
rating as the branch circuit on which the air compressor is operated. If
compressor is connected to a circuit protected by fuses, use only time delay
fuses. Time delay fuses should be marked "D" in Canada and "T" in the US.

Содержание CPLMC7580V2C

Страница 1: ...tions before starting operations Part No D24225 049 2 ESPA OL P GINA 27 FRAN AIS PAGE 53 To learn more about Porter Cable visit our website at http www porter cable com CPLMC7580V2C Copyright 2004 Por...

Страница 2: ...State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are G lead from lead based paints G crystalline silica from bricks and cement and other ma...

Страница 3: ...M ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS OPERATE COMPRESSOR IN A CLEAN DRY WELL VENTILATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AR...

Страница 4: ...BALLS BASKETBALLS ETC 1 FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATION...

Страница 5: ...ARTICLES FROM THE TANK BREATHING THESE CONTAMINANTS CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOLVENTS PAINT REMOVER INSECTICIDES WEED KILLERS CONTAIN HARMFUL VAPORS AND...

Страница 6: ...TEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN HAZARD HOW TO PREVENT IT WHAT CAN...

Страница 7: ...low pressure at which the motor automatically restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It...

Страница 8: ...essor without first adding oil to the crankcase Serious damage can result from even limited operation unless filled with oil and broken in correctly Make sure to closely follow initial start up proced...

Страница 9: ...ion of the Air Compressor Locate the air compressor in a clean dry and well ventilated area Located the air compressor at least 12 away from the wall or other obstructions that will interfere with the...

Страница 10: ...product specification found in the front of this manual for the voltage and minimum branch circuit requirements RISK OF ELECTRICAL SHOCK Improper electrical grounding can result in electrical shock T...

Страница 11: ...nd main air distribution line to allow for vibration A separate regulator is recommended to control the air pressure Air pressure from the tank is usually to high for individual air driven tools DRAIN...

Страница 12: ...air discharge valve Turn knob counter clockwise to open and clockwise to close Drain Valve The drain valve is located at the base of the air tank and is used to drain condensation at the end of each u...

Страница 13: ...s See Maintenance How to Use Your Unit How to Stop 1 Set the On Auto Off lever to OFF Check Valve Pressure Release Valve Before Starting Break in Procedure Serious damage may result if the following b...

Страница 14: ...o operate a sprayer DO NOT place compressor near the spray area Before Each Start Up 1 Place On Auto Off lever to OFF 2 Close the globe valve 3 Attach hose and accessories NOTE A regulator MUST be ins...

Страница 15: ...Before performing any maintenance or repair disconnect power source from the compressor and bleed off all air pressure To Check Safety Valve If the safety valve does not work properly over pressuriza...

Страница 16: ...capacity is approximately 40 fluid ounces 1 2 L Overfilling with oil will cause premature compressor failure Do not overfill 5 Replace oil fill plug A and tighten securely To Drain Tank NOTE Operation...

Страница 17: ...weight is applied at the midway point 3 When proper belt tension is achieved tighten all four motor mounting screws See Parts manual for torque specifications NOTE Once the engine pulley has been move...

Страница 18: ...belt guard 3 Place a straightedge against the outside of the flywheel and the motor drive pulley 4 Measure the distance between the edge of the belt and the straightedge at points A1 and A2 in figure...

Страница 19: ...ressure Allow the air compressor to cool To Replace or Clean Check Valve 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Turn air compressor off lock out the po...

Страница 20: ...This motor has a manual thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting To res...

Страница 21: ...slowly bleed from the air tank until tank pressure is approximately 20 psi 6 Drain water from air tank by opening drain valve counter clockwise on bottom of tank Water will condense in the air tank If...

Страница 22: ...s where air can be heard escaping Check fittings with soapy water solution DO NOT OVERTIGHTEN Air leaks at fittings Air leaks at pressure switch release valve if equipped Defective pressure switch rel...

Страница 23: ...ction Pressure reading on the regulated pressure gauge if equipped drops when an accessory is used It is normal for some pressure drop to occur If there is an excessive amount of pressure drop when th...

Страница 24: ...load switch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Loose electr...

Страница 25: ...ained Service Technician Belt to tight Check belt tension see Adjusting Belt Tension in the Maintenance section Excessive belt wear Loose belt Tight belt Loose pulley Have checked by a Trained Service...

Страница 26: ...and materials or other contaminants Expendable items that become worn during normal use such as drain valves fuses filters belts air cleaners spark plugs engine oil and pump oil Cosmetic defects that...

Отзывы: