6- ENG

A10055

WARNING: Risk of Burns

Touching exposed metal 

such as the 

compressor head or outlet tubes,

 can 

result in serious burns.

Never touch any exposed metal parts 

on compressor 

during or immediately 

after operation. 

Compressor will remain 

hot 

for several minutes after operation.

Do not 

reach around protective shrouds 

or 

attempt maintenance until unit has 

been allowed to cool.

WARNING: Risk from Moving Parts

Never operate the compressor with 

guards 

or covers which are

 damaged or 

removed.

Moving parts 

such as the pulley, flywheel, 

and belt

 can cause serious injury 

if 

they come into contact with you or your 

clothing.

WARNING: Risk of Falling

A portable 

compressor can fall

 from 

a table, workbench, or roof c

ausing 

damage to the compressor and could 
result in serious injury or death to the 
operator.

Always 

operate compressor in a stable 

secure position

 to prevent accidental 

movement of the unit. 

Never operate 

compressor on a roof or other elevated 
position. Use additional air hose to 
reach high locations.

HAZARD

HAZARD

HAZARD

Any

 repairs 

required on this product 

should be performed by authorized 

service center personnel.

Attempting to operate

 compressor 

with 

damaged or missing parts

 or attempting 

to repair compressor with protective 

shrouds removed can expose you to 

moving parts and 

can result in serious 

injury.

How To Prevent It

What Could Happen

How To Prevent It

What Could Happen

How To Prevent It

What Could Happen

Содержание CLFRP350

Страница 1: ...structions before starting operations Part No A10055 051 0 ESPA OL P GINA 25 FRAN AIS PAGE 49 To learn more about Porter Cable visit our website at http www porter cable com Copyright 2005 Porter Cabl...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...run air pressure in the air tank begins to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high...

Страница 9: ...only NOTE Use an oil specifically formulated for use in an air compressor such as Porter Cable PAS1 air compressor oil Oil may be found at the store where the air compressor was purchased 1 Place unit...

Страница 10: ...se if there are signs of damage 4 If these grounding instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qual...

Страница 11: ...NOT USE 14 OR 16 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit...

Страница 12: ...pressure Tank Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure gauge Pull the knob out and turn cl...

Страница 13: ...the side of the pressure switch is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches cut out pressure or is shut off The pr...

Страница 14: ...accessories to prevent hose backlash NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket Risk of Bursting Too much air pressure caus...

Страница 15: ...e checks To Check Safety Valve Risk of Bursting If the safety valve does not work properly over pressurization may occur causing air tank rupture or an explosion 1 Before starting compressor pull the...

Страница 16: ...e to air compressor and possible personal injury See Troubleshooting for correction Risk of Unsafe Operation Overfilling with oil will cause premature compressor failure Do not overfill Checking 1 Set...

Страница 17: ...lock into place Motor The motor has an automatic reset thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to coo...

Страница 18: ...c in the closed position if not the check valve needs to be cleaned or replaced 8 Clean or replace the check valve A solvent such as paint or varnish remover can be used to clean the check valve 9 App...

Страница 19: ...to bleed from the tank until tank pressure is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense...

Страница 20: ...nk welds Defective air tank Air tank must be replaced Do not repair the leak Risk of Bursting Do not drill into weld or otherwise modify air tank or it will weaken The tank can rupture or explode Air...

Страница 21: ...rained Service Technician Regulator knob has continuous air leak Regulator will not shut off air outlet Damaged regulator Have checked by a Trained Service Technician Possible defect in safety valve O...

Страница 22: ...xceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Loose electrical connections Check wiring connection inside pres...

Страница 23: ...ee Parts manual for torque specifications Carbon build up in pump Have checked by a Trained Service Technician Squealing sound Compressor pump has no oil See Oil Checking paragraph in the Maintenace s...

Страница 24: ...purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service c...

Отзывы: