Porter-Cable CLFCP350 Скачать руководство пользователя страница 8

8- ENG

A02212

GLOSSARY

Become familiar with these terms before operating the unit.

CFM

:  Cubic feet per minute.

SCFM:

Standard cubic feet per minute; a unit of measure of air delivery.

PSIG:

Pounds per square inch gauge; a unit of measure of pressure.

Code Certification: 

Products that bear one or more of the following marks:

UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent
safety laboratories and meet the applicable Underwriters Laboratories
Standards for Safety.

Cut-In Pressure:

While the motor is off, air tank pressure drops as you

continue to use your accessory. When the tank pressure drops to a certain low
level the motor will restart automatically.  The low pressure at which the motor
automatically restarts is called “cut-in” pressure.

Cut-Out Pressure:

When an air compressor is turned on and begins to run,

air pressure in the air tank begins to build.  It builds to a certain high pressure
before the motor automatically shuts off - protecting your air tank from
pressure higher than its capacity.  The high pressure at which the motor shuts
off is called “cut-out” pressure.

Branch Circuit: 

Circuit carrying electricity from electrical panel to outlet.

DUTY CYCLE

This air compressor pump is capable of running continuously. However, to
prolong the life of your air compressor, it is recommended that a 50%-75%
average duty cycle be maintained; that is, the air compressor pump should not
run more than 30-45 minutes in any given hour.

SPECIFICATIONS

Model No.

CLFCP350

Horsepower Peak

2.5

Bore

2.363”

Stroke

.890”

Voltage-Single Phase

120

* * Minimum Branch Circuit Requirement

15 amps

*

Fuse Type

Time Delay

Air Tank Capacity (Gallon)

4.3

Approximate Cut-in Pressure

150 PSIG

Approximate Cut-out Pressure

180 PSIG

SCFM @ 40 PSIG

5.7

SCFM @ 90 PSIG

4.4

Risk of Unsafe Operation. 

These compressors can be

operated on a 15 amp circuit if:

1.

Voltage supply to circuit must comply with the National Electrical Code.

2.

Circuit is not used to supply any other electrical needs (lights, appliances, etc.).

3.

Extension cords comply with specifications in owners manual.

4.

Circuit is equipped with 15 amp circuit breaker or 15 amp time delay fuse.

If any of the above conditions cannot be met, or if operation of the compressor repeated-
ly causes interruption of the power it may be necessary to operate it from a 20 amp
circuit. It is not necessary to change the cord set.

* * A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating

as the branch circuit on which the air compressor is operated. If compressor is
connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses
should be marked "D" in Canada and "T" in the US.

Содержание CLFCP350

Страница 1: ...structions before starting operations Part No A02212 043 1 ESPA OL P GINA 25 FRAN AIS PAGE 49 To learn more about Porter Cable visit our website at http www porter cable com Copyright 2004 Porter Cabl...

Страница 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Страница 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Страница 4: ...ondensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairsto the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Страница 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Страница 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Страница 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Страница 8: ...ntinuously However to prolong the life of your air compressor it is recommended that a 50 75 average duty cycle be maintained that is the air compressor pump should not run more than 30 45 minutes in...

Страница 9: ...nly NOTE Use an oil specifically formulated for use in an air compressor such as Porter Cable PAS1 air compressor oil Oil may be found at the store where the air compressor was purchased 1 Place unit...

Страница 10: ...instructions are not completely understood or if in doubt as to whether the compressor is properly grounded have the installation checked by a qualified electrician Risk of Electrical Shock IMPROPER...

Страница 11: ...NOT USE 14 OR 16 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit...

Страница 12: ...essure Tank Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure gauge Pull the knob out and turn cloc...

Страница 13: ...re release valve located on the side of the pressure switch is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches cut out pre...

Страница 14: ...accessories to prevent hose backlash NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket Risk of Bursting Too much air pressure cause...

Страница 15: ...e checks To Check Safety Valve Risk of Bursting If the safety valve does not work properly over pressurization may occur causing air tank rupture or an explosion 1 Before starting compressor pull the...

Страница 16: ...essure can build in crankcase causing damage to air compressor and possible personal injury See Troubleshooting for correction Risk of Unsafe Operation Overfilling with oil will cause premature compre...

Страница 17: ...lock into place Motor The motor has an automatic reset thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to coo...

Страница 18: ...c in the closed position if not the check valve needs to be cleaned or replaced 8 Clean or replace the check valve A solvent such as paint or varnish remover can be used to clean the check valve 9 App...

Страница 19: ...to bleed from the tank until tank pressure is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense...

Страница 20: ...nk welds Defective air tank Air tank must be replaced Do not repair the leak Risk of Bursting Do not drill into weld or otherwise modify air tank or it will weaken The tank can rupture or explode Air...

Страница 21: ...rained Service Technician Regulator knob has continuous air leak Regulator will not shut off air outlet Damaged regulator Have checked by a Trained Service Technician Possible defect in safety valve O...

Страница 22: ...xceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Loose electrical connections Check wiring connection inside pres...

Страница 23: ...ee Parts manual for torque specifications Carbon build up in pump Have checked by a Trained Service Technician Squealing sound Compressor pump has no oil See Oil Checking paragraph in the Maintenace s...

Страница 24: ...purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service c...

Отзывы: