14 - ENG
TO REPLACE REGULATOR
1. Release all air pressure from air tank. See
To Drain Tank
in the
Maintenance
section.
2. Unplug unit.
3. Using an adjustable wrench remove the gauges, quick connects, and safety
valve from the regulator manifold.
4. Remove the hose by removing the hose clamp.
NOTE:
The hose clamp is not
reusable. You must purchase a new hose clamp, see
Replacement Parts
in
the
Service
section or purchase a standard hose clamp at a local hardware
store.
5. Loosen the nut on the outlet tube and move the outlet tube to the side.
Safety
Valve
Regulator
Manifold
Quick
Connects
Gauges
6. Remove pump mounting screws securing pump (one on each side).
Pump
Mounting
Screw
Hose Clamp
Pump shown
moved out of
the way
Regulator
Manifold
7. Carefully slide pump from brackets and out of the way.
8. Using an adjustable wrench remove the regulator manifold.
9. Apply pipe sealant to new regulator manifold and assemble, tighten with
wrench.
10. Reapply pipe sealant to gauges, quick connects, and safety valve.
11. Reassemble all components in reverse order of removal. Make sure to orient
gauges to read correctly and use wrenches to tighten all components.