GLOSSARY

DUTY CYCLE

Accessories for this unit are available at the store the unit was purchased.

ACCESSORIES

Become familiar with these terms
before operating the unit.

CFM

:  Cubic feet per minute.

SCFM:

Standard cubic feet per

minute; a unit of measure of air
delivery.

PSIG:

Pounds per square inch

gauge; a unit of measure of pressure.

Code Certification: 

Products that

bear one or more of the following
marks: UL, CUL, ETL, CETL, have
been evaluated by OSHA certified
independent safety laboratories and
meet the applicable Underwriters
Laboratories Standards for Safety.

Cut-In Pressure:

While the motor is

off, air tank pressure drops as you
continue to use your accessory.

When the tank pressure drops to a
certain low level the motor will restart
automatically.  The low pressure at
which the motor automatically
restarts is called "cut-in" pressure.

Cut-Out Pressure:

When an air

compressor is turned on and begins
to run, air pressure in the air tank
begins to build.  It builds to a certain
high pressure before the motor
automatically shuts off - protecting
your air tank from pressure higher
than its capacity.  The high pressure
at which the motor shuts off is called
"cut-out" pressure.

Branch Circuit: 

Circuit carrying

electricity from electrical panel to
outlet.

This air compressor pump is capable
of running continuously. However, to
prolong the life of your air
compressor, it is recommended that a

50%-75% average duty cycle be
maintained; that is, the air compressor
pump should not run more than 30-45
minutes in any given hour.

SPECIFICATIONS

Model No.

CPFAC2040P

Horsepower Peak

2.0

Bore

1.875"

Stroke

1.250"

Voltage-Single Phase

120

Minimum Branch Circuit Requirement

15 amps

Fuse Type

Time Delay

Air Tank Capacity (Gallon)

4

Approximate Cut-in Pressure

110 PSIG

Approximate Cut-out Pressure

135 PSIG

SCFM @ 40 PSIG

3.7

SCFM @ 90 PSIG

2.6

Содержание C2000

Страница 1: ...______________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations Part No D26130 041 1 ESPAÑOL PÁGINA 19 FRANÇAISE PAGE 37 To learn more about Porter Cable visit our website at http www porter cable com MODEL CPFAC2040P Copyright 20...

Страница 2: ... the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints crystalline silica from br...

Страница 3: ...property damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If spraying flammable materials locate compressor at least 20 feet away from spray area An additional length of hose may be required Store flammable materials in a secure location away from comp...

Страница 4: ...ondensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure Never drill into weld or make any modifications to the tank or its attachments Excessive vibration can weaken the air tank and cause rupture or explosion The tank is desi...

Страница 5: ...rect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials such as paint paint solvents paint remover insecticides weed killers may contain harmful vapors and poisons Air o...

Страница 6: ...othing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate compressor in a stable secure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations HAZARD ...

Страница 7: ... parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Transporting Compressor Oil can leak or spill and could result in fire or breathing hazard serious injury or death can result oil leaks will damage carpet paint or other surfaces in vehicles or trailers ...

Страница 8: ... restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off is called cut out pressure Branch Circuit Circuit carrying ...

Страница 9: ...rounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly grounded The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug see following illustrations 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The out...

Страница 10: ... NOT USE 16 OR 18 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other electrical needs 3 Extension cords comply with...

Страница 11: ...Safety Valve Pressure Switch Tank Pressure Gauge Outlet Pressure Gauge Regulator Quick Connect Description of Operation Become familiar with these controls before operating the unit On Auto Off Switch Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use Pressure Switch The pressure switch automatically starts the motor when the air ta...

Страница 12: ...he compressor will start 5 Run the compressor for 15 minutes Make sure the drain valve is open and there is minimal air pressure build up in tank 6 After 15 minutes close the drain valve The air receiver will fill to cut out pressure and the motor will stop The compressor is now ready for use Air Compressor Pump not shown Compresses air into the air tank Working air is not available until the comp...

Страница 13: ... tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety Valve Drain Tank NOTE See Operation section for the location of controls Unit cycles automatically when power is on When performing maintenance you may be exposed to voltage sources compressed air or moving par...

Страница 14: ...d the reinstalled Open Drain Valve Closed Drain Valve To Replace or Clean Check Valve 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug unit 3 Remove the hose by removing the hose clamp NOTE The hose clamp is not reusable You must purchase a new hose clamp see the Parts List Manual or purchase a standard hose clamp at a local hardware store SERVICE AND ...

Страница 15: ...Apply pipe sealant tape to the nipple on the standpipe 6 Assemble the regulator and orient as shown NOTE Arrow indicates flow of air Make sure it is pointing in the direction of air flow 7 Reapply pipe sealant to outlet pressure gauge and quick connect 8 Reassemble outlet pressure gauge and quick connect Orient outlet pressure gauge to read correctly Tighten connect with wrench To Replace Regulato...

Страница 16: ... is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 7 After the water has been drained close the drain or drain valve NOTE If drain valve is plugged release all air pressure The valve ca...

Страница 17: ...17 ENG D26130 NOTES ...

Страница 18: ...aser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service call arrangements If the purchaser does not receive satisfactory results from the Porter Cable Authorized Warranty Service Center the purchaser should contact Porter Cable THIS WARRANTY DOE...

Отзывы: