3) If placed near a wall or other obstruction, position the product a minimum of 3 feet (0.9 meters) from the wall or obstruction with pads facing the wall. This
allows the unrestricted flow of warm air to the cooling pad side of the product. When using multiple products in close proximity, be sure to aim the product so the
air flows complement each other to achieve maximum cooling capacity.
S
WDUWLQJ
WKH
P
XPS
DQG
A
GMXVWLQJ
WKH
W
DWHU
)ORZ
Once the water tank is full, moving the pump switch to the “ON” position will turn on the pump. When initially turning on the pump, the level in the water tank will drop suddenly
and restart the flow of supply water. This is a normal condition, as the cooling pads re
T
uire a large amount of water for proper wetting.
When the Portacool evaporative cooler is new, the new pads will re
T
uire an initial
Ҋ
breaking-in
ҋ
period. This period is re
T
uired for the pads to begin readily absorbing water. It
may re
T
uire up to a week to achieve maximum efficiency.
It is important to ensure that the spray bar is properly adjusted when first starting the water flow in the Portacool evaporative cooler. Increasing the flow using the water flow valve
(see Quick Setup on page 2) makes this adjustment. Proper water adjustment should leave the pads saturated with water, but not flooded. Pads should appear wet. However,
cascading amounts of water can actually reduce cooling efficiency. Proper adjustment will prevent problems and increase cooling capacity. When properly adjusted, one or two dry
streaks will appear across the pads.
When turning the evaporative cooler off at the end of the day or week, the pump should be turned off about 15 minutes before the fan to allow the cooling pads to dry. This will
increase the life of the pads.
S
WDUWLQJ
WKH
P
RUWDFRRO
E
YDSRUDWLYH
C
RROHU
COOLING PADS MUST BE INSTALLED AND CASTER LOCKS MUST BE ENGAGED
Start the fan by turning the fan switch to the
Ҋ
ON
ҋ
position. Step slowly through the speeds allowing the fan to obtain its full speed at the LOW speed before
going to HIGH.