OPERATION WARNINGS

SAFE OPERATION

1)  Not for use by children
2)  Not for use by persons with reduced physical, sensory or mental capabilities
3)  Not for use by persons who have not reviewed the owner’s manual and familiarized themselves with the operation of the product

To reduce the risk of electric shock, fire or injury:

•  Do not operate any evaporative cooler with a damaged cord 

or plug. 

•  Do not run power cord under carpeting or cover with 

throwrugs, runners or similar coverings. Arrange power cord 

away from traffic areas to avoid tripping hazards.  

•  Read the evaporative cooler’s instructions, owner’s manual 

and labels thoroughly before use.

•  Always unplug the power cord to the evaporative cooler 

before performing inspections or repairs.

•  Do not step on or roll over power cord with heavy or sharp 

objects.

•  Do not operate evaporative cooler unless all KUUL

®

 

evaporative media is securely in place.

•  Test the GFCI receptacle or breaker monthly to ensure it is 

functioning properly.

•  Remove the plug from the electrical receptacle by pulling on 

the plug, not the power cord.

•  Operation near open flames or sparks is not recommended.

•  If operating near open flame or sparks, ensure the pump 

is continuously running in order to saturate and wet KUUL    

evaporative media.

•  When cleaning your evaporative cooler, ensure water does 

not get into the motor or electrical system to prevent 

damage.

•  The use of extension cords with your evaporative cooler is 

not recommended. However, if the owner determines that 

his or her circumstance or intended use requires the use of 

an extension cord, the following requirements must be met:

 

- Extension cord must be 14 gauge or greater;

 

- Extension cord must not exceed 50 (15.24 meters) 

            feet in length; and

 

- Extension cord must be properly grounded.

•  Evaporative coolers should not be modified in any way 

(other than repairs made by qualified individuals with 

Portacool replacement parts). 

•  If the evaporative cooler is damaged or malfunctions, 

do not continue to operate it. Refer to the warranty, 

troubleshooting or FAQ sections of this owner’s manual, 

call Portacool, LLC Customer Service at 

(936) 598-5651 or 

(800) 695-2942

, or email [email protected].

SAFETY

Содержание CYCLONE PACCY110

Страница 1: ...PORTACOOL CYCLONE OWNER S MANUAL PAC2KCYC01 PACCYC02 PACCY110 PACCY120 PACCY130 PACCY160 Applies to all 120 and 240V products for global configurations...

Страница 2: ...before use Turn to the left to increase water flow If entrainment occurs water is spitting from the front of the product use the valve to decrease the water flow until entrainment ceases 4 5 Your Port...

Страница 3: ...ove the plug from the electrical receptacle by pulling on the plug not the power cord Operation near open flames or sparks is not recommended If operating near open flame or sparks ensure the pump is...

Страница 4: ...OL CYCLONE 2000 Drain located in back Casters Adjustable louvers Control panel Water adjustment valve Power cord with GFCI KUUL Comfort evaporative media Serial plate Hose connection Fill door Liquid...

Страница 5: ...OL CYCLONE 3000 Drain located in back Casters Control panel Water adjustment valve Hose connection Power cord with GFCI KUUL Comfort evaporative media Adjustable louvers Serial plate Fill door Liquid...

Страница 6: ...select distributors Drain located in back Recessed casters Fill door Adjustable louvers Control panel Liquid Level Indicator Hose connection Power cord with GFCI OVERVIEW KUUL Comfort evaporative med...

Страница 7: ...rough select distributors OVERVIEW Drain located in back Casters Fill door Adjustable louvers Control panel Liquid Level Indicator Hose connection Power cord with GFCI KUUL Comfort evaporative media W...

Страница 8: ...rough select distributors OVERVIEW Drain located in back Casters Fill door Adjustable louvers Control panel Liquid Level Indicator Hose connection Power cord with GFCI KUUL Comfort evaporative media W...

Страница 9: ...Sold only through select distributors OVERVIEW Drain located on bottom Casters Control panel Liquid Level Indicator Hose connection Power cord with GFCI KUUL Comfort evaporative media Water adjustmen...

Страница 10: ...ow leakage currents Portacool Cyclone models PAC2KCYC01 PACCYC02 PACCY160 PACCY130 PACCY120 and PACCY110 use a GFCI which is built into the power cord The GFCI on these models will automatically reset...

Страница 11: ...and alert the user that the pump has shut off This light may cycle on and off for a few minutes to draw attention to the low water condition as it tries to exhaust the remaining water In order to res...

Страница 12: ...G THE WATER FLOW Once the tank is full of water flip the pump switch into the on position The water level in the tank may drop suddenly and restart the flow of supply water This is a normal condition...

Страница 13: ...L evaporative media in correct airflow direction referring to the label on the KUUL evaporative media If conditions such as hard water warrant Portacool Hard Water Treatment can be purchased at www po...

Страница 14: ...2 Replace motor 1 Move evaporative cooler at least three feet from the wall 2 Replace fan motor 3 Replace capacitor 1 Replace float valve 2 Tighten plug 1 Check and tighten where needed 2 Inspect and...

Страница 15: ...agnant water in tank 2 KUUL evaporative media is mildewed or clogged 1 Too much water delivered to KUUL evaporative media 2 Leaking hose REMEDY 1 Drain flush and clean tank 2 Replace KUUL evaporative...

Страница 16: ...does not cover ordinary wear and tear and is non transferrable If the Equipment and or its original component parts including product housings develop a defect covered by this limited warranty within...

Страница 17: ...e following components are included with your Portacool Cyclone series product For complete warranty information and limitations please see Warranty page Beyond these aspects of Portacool Protect we a...

Страница 18: ...uld be below 75 However Portacool evaporative coolers will reduce the temperature in almost any environment making it more comfortable Q How often should my KUUL ComfortTM evaporative media be replace...

Страница 19: ...a safe place to prevent damage while out of the evaporative cooler Once all the KUUL Comfort evaporative media has been removed you should have access to the inside of the evaporative cooler and inter...

Страница 20: ...LCYC00A PARCTLCYC00A PARCTLCYC00A PARCTLCYC00A PARCTLCY160A COVER PAC CVR C2 PAC CVR 02 PARCVRCYC06 PAC CVR C2 PAC CVR 02 PAC CVR 01 HARD WATER TREATMENT PARPACHWTB00 PARPACHWTB00 PARPACHWTB00 PARPACH...

Страница 21: ...NOTES...

Страница 22: ...NOTES...

Страница 23: ...NOTES...

Страница 24: ...s 75935 936 598 5651 www portacool com www theKUULeffect com The manual is available in other languages To download a digital copy please visit www portacool com El manual est disponible en otros idio...

Отзывы: