background image

01474 761 051 

www.portablepowertech.com 

10 

IMPORTANT NOTE : The black wire must be terminated to chassis for the in vehicle charging 

to work. 

 

NOTE  :  In  vehicle  charging  from  either  alternator  or  solar  is  independent  of  the  isolator 

switch position – both the DC-DC charger and MPPT solar controller are directly connected 

to the Vehicle Power Hub battery. 

 

Charging from Solar 

Vehicle Power Hub has an integrated MPPT solar charge controller making solar charging easy. 
 

TIP :

 Solar will also top up and maintain the starter battery when the Hub battery is full 

 
1. 30A MPPT Solar Charger built-in - ensure the max charging current from the solar panel or 
array is not more than 30A, and open circuit voltage is not more than 25Vdc 

– therefore a 

12V 

solar panel only

 can be used (typically open circuit voltage would be around 20V to 23V) 

 
2. Place the solar panel in direct sun 
 
3. Using the supplied solar cable (Red/Black MC4 to Anderson) connect the solar panel with the 
YELLOW port marked 

“12V SOLAR INPUT” 

Содержание Vehicle Power Hub 1300

Страница 1: ...VEHICLE POWER HUB Lithium Power Supply with in built DC DC charger and solar controller USER MANUAL...

Страница 2: ...Instructions 6 General Precaution 7 Charging the Vehicle Power Hub 8 Operating Instructions 11 Multi Function Display 13 Troubleshooting 14 Specifications 15 In the Box 16 Maintenance 17 Warranty 18 P...

Страница 3: ...provides high energy storage burn less fuel and reduce CO2 emissions when running high loads for long periods Fast efficient in vehicle charging means less idling is required to maintain loads Flexibl...

Страница 4: ...ion battery pack Before using or storing please charge the Vehicle Power Hub by the lithium ion AC charger supplied until it s fully charged Don t leave the Vehicle Power Hub stored for extended peri...

Страница 5: ...ITCH B MULTI FUNCTION DISPLAY C EXTERNAL DC12V INVERTER OUTLET D 50A INPUT OUTPUT E IN VEHICLE CHARGE INPUT BLUE F 12V SOLAR INPUT YELLOW G USB 5V 2 X 2 1A H DC 12V 10A SOCKET I IGN SIGNAL CONNECTION...

Страница 6: ...ehicle Power Hub DC isolator is turned off before opening and servicing This manual contains information concerning the storage and operation of the Vehicle Power Hub All relevant parts of the manual...

Страница 7: ...wires are exposed Do not place foreign objects inside the power outlets or ventilation holes Always keep and use the device out of the reach of children Do not open the unit without permission and pr...

Страница 8: ...witch is always turned ON during charging 2 Plug AC charger into wall outlet using the included power cord 3 Connect the Anderson plug of AC charger to 50AMP INPUT OUTPUT outlet 4 During the charging...

Страница 9: ...is burnt out or the DC DC charger is not working The integrated battery to battery charger is compatible with both older conventional alternators and new variable voltage alternators EU6 fitted to ne...

Страница 10: ...n integrated MPPT solar charge controller making solar charging easy TIP Solar will also top up and maintain the starter battery when the Hub battery is full 1 30A MPPT Solar Charger built in ensure t...

Страница 11: ...independent of the isolator switch DC Operation Max 250A Total output BMS limited 1 Please ensure the TOTAL discharging current is not more than 250A or else it may trigger the main internal power br...

Страница 12: ...terminated with large Anderson connector and M8 ring terminals 1 Turn off power hub using main isolator 2 Connect the correct red and black ring terminals to the corresponding and terminals on the pow...

Страница 13: ...ain Switch isolator to ON to power the multi function display 2 Please press ON OFF button to check the Battery Capacity and Voltage Turning the Isolator switch to OUT allows the isolator switch to be...

Страница 14: ...n vehicle charger and MPPT Solar Charger Under permission and instruction from PPT remove the screws and open the lid to inspect 40A inline fuse holder Replace 40A fuse if needed with the same size fu...

Страница 15: ...Max discharge 250A BMS over current and over temperature limited max 200A continuous Output Specification DC Outlet Dual 5V 2 1A USB 2X 12V 10A DC socket 2x 12V 50A connector input output 1x External...

Страница 16: ...ted with large Anderson connector M8 ring terminals x1 and inline 225A circuit breaker Starter battery connection cable for in vehicle charging 1 metre 10mm cable red and black Blue Anderson connector...

Страница 17: ...ully recharge the Vehicle Power Hub every 3 months especially when not in use 3 Turn the main battery isolator to OFF when the Vehicle Hub is not in use 4 Check the lid bolts are tight every 6 months...

Страница 18: ...ability for any 3rd party damage however so caused Under this warranty we will replace or repair any parts found to be defective due to manufacturers defect We are not responsible in any way for damag...

Страница 19: ...ech com 19 Portable Power Technology Ltd Unit 2 Meadow House Business Centre Meadow House London Road West Kingsdown Kent TN15 6ER United Kingdom Tel 44 0 1474 761 051 Email sales portablepowertech co...

Отзывы: