3.1 Battery Information
3.2 Output
3.3 Charging
3.4 General Information
3. Product Specification
4. Caution Advice
1. Do not short-circuit the product. To avoid short-circuiting, keep the product away from small metal
objects. (e.g. Coins, hair-pins, keys, paper clips)
2. Do not heat the product or dispose it in fire, water or other liquids. Keep the product away from high
ambient temperature. Do not leave the product unattended in direct sunlight.
3. Keep the product away from humid or dusty places.
4. Do not disassemble / reassemble this product as this will void any warranty given on the product.
5. Do not drop or place heavy objects on this product. Avoid any strong impacts with the product.
6. This product is not intended to be used by any person with reduced physical, sensory or mental
capabilities. Please keep the product away from children.
7. This is not a licensed medical product and is not intended to be used with medical devices.
8. Portable Power Technology LTD is not responsible for any loss of life that may occur when using
this powerpack for medical purposes. (e.g. Using the product to power a respiratory machine)
9. Do not cover the product with towels, clothing or other items that may restrict airflow or create heat.
10. Please ensure not to overcharge the powerpack.
11. When fully charged, disconnect the product from the power source immediately.
12. While charging, keep away from TV, radio and other equipment to avoid radio wave interference.
13. If you are not going to use this product for a long time, we advise fully recharging the powerpack
before storage. Then to ensure battery life, fully recharging at least once every 3 months.
14. To charge some portable electronic devices you may need to set those devices into charge mode.
Refer to the corresponding user manual of those devices for confirmation.
7. Warranty Service
Your 1000R-LF is supplied with a 12-month warranty from the date of purchase against defects in
material and workmanship under normal use and service.
Should your Powerpack 1000R-LF prove defective within 1 year from the date of purchase, please
contact us for a returns number wuoting the serial number and return the product, along with a copy
of the prrof of purchase and an explanation of the fault.
We do not accept liablity for any 3
rd
part damage however so caused.
Under this warranty we will replace or rpair any parts found to be defective due to manufacturers
defect.
We are not responsible in any way for damages, losses, or invinencience caused by equipment
failure or by user negligence, abuse, or use not in accordance with the “User Manual” or any other
additional safety, use, or warnings included in the product materials.
Furthermore we are not liable for incidental, data loss, or consequential damages of any nature
resulting from the use of this product and any liability shall not exceed the purchase price of the
products.
Cell Type
LiFePO4
Battery Capacity
1382Wh (25.6V / 54Ah)
Life Cycle
>2000 Cycles at 80%
Shelf-life
Charge to full every 3 months minimum.
Fault Code
Fault Name
Fault
E01
Inverter short circuit protection
Check if the output port is overloaded or
shorted
E02
Inverter overload protection
Check if the output port is overloaded or
shorted
E03
Inverter over temperature protection
Check whether the enviroment temperature is
higher than 45°C. Check to see if unit is close
to a heat source, and whether it is placed to
accommodate ventilation and heat dissipation
E04
Overload protection
Remove Load
E05
Battery damage
Restart product, if problem persists contact us
E06
Battery charge low temperature
protection
Check if the enviroment temperature is
below -0°C.
E07
Battery discharge low temperature
protection
Check if the enviroment temperature is
below -20°C.
E08
Battery discharge high temperature
protection
Check whether the enviroment temperature is
higher than 45°C. Check to see if unit is close
to a heat source, and whether it is placed to
accommodate ventilation and heat dissipation
E09
Battery discharge high temperature
protection
Check whether the enviroment temperature is
higher than 45°C. Check to see if unit is close
to a heat source, and whether it is placed to
accommodate ventilation and heat dissipation
E10
Inverter hardware error
Inspect the internal inverter part
E11
Discharge hardware error
Inspect the internal charging hardware
E12
Charger hardware error
Inspect the charger
E13
Communication error
Inspect the internal comms of the inverter
AC Adapter
DC 28V / 7A
Solar PV Input (MPPT)
12V-36V / 8A Max, 240W Max
DC In-Vehicle
12 / 24V
USB 2.0
5V @ 2.4A Max
USB 3.0
(x2)
5V @ 0 ~ 3A 18W Max
(9V @ 2A) (12V @ 1.5A)
USB Type-C
5V ~ 20V @ 3A, 60W Max
(Supports PD)
DC 12V Port
(x3)
DC5521
12V @ 10A Max
DC 24V Port
DC5525
18V~29V @ 5A Max
AC 230V UK sockets
12V @ 10A Max
Net Weight
20Kg
Product Dimensions
392mm x 208mm x 267mm
Storage Temperature
-20~65°C
Operating Temperature
0~55°C
Relative humidity
65
±
20%RH
2.3 Buttons and Functions
Note:
Each button has a key LED light built in that will illuminate when in the Active state.
A. Power On / Off
This is located on the front of the powerpack, directly above the left most AC 230V socket.
To turn the unit on or off press and hold the power button for up to 5 seconds. Once powered on the
powerpack will turn off after 5 minutes if none of the AC, DC or USB outputs have been activated.
You can power off the unit to turn off any of the following functions.
B. AC On / Off
This is located on the front of the powerpack, directly above the two AC 230V sockets.
To activate / deactivate AC functionality, press and hold this button for 1 second. If the AC is enabled
the AC indicator
(G)
will be set to ON and you’ll be able to draw 230V from both AC sockets.
You can monitor the power consumption
(J)
from any loads connected to the AC 230V socket.
Note:
Please ensure that any 230V AC loads connected do not exceed 1000W max shared .
C. LED Torch On / Off
This is located on the rear of the powerpack, at the very top, indicated by a green flash light icon.
To activate ensure the powerpack is powered on then press and hold this button for 3 seconds.
Once on, you can long press (1 second) this button again to activate S.O.S mode.
Long press again to switch back to standard torch mode.
To power off the torch, press and hold the button for 5 seconds, until the light is turned off.
Note:
S.O.S mode may activate while the holding down the flash light button to turn off.
D. USB Output On / Off
This is located on the rear of the powerpack, above the USB outputs.
To activate / deactivate USB functionality, press and hold this button for 1 second. If USB power is
Enabled the DC indicator
(F)
will be set to ON. You will notice no change if DC power is already on.
You can monitor the total power consumption
(I)
from any DC and USB loads connected.
The top USB 2.0 port provides a maximum output current of 2.4A.
The following 2x USB 3.0 ports output the following: [ 5V / 3A ] [ 9V / 2A ] [ 12V / 1.5A ]
Type-C USB port supports PD (Power transfer) 5V-20V with a maximum output current of 3A.
E. DC Output On / Off (12V / 24V)
This is located on the rear of the powerpack, above the 4 DC ports.
To activate 12V functionality, press and hold this button for 1 second. (Long Press)
This will provide power to the large 12V socket and 3x 12V DC ports on the back of the unit.
Long press this button a second time to activate the 24V functionality to the 24V DC port.
Long pressing a third time will turn both 12V and 24V functionality off.
If DC is activate, the indicator
(F)
will be set to ON. If the unit is in 12V mode, you can see this on the
LCD display (H). If in 24V mode, both 12V and 24V indicators will be active.
You can monitor the total power consumption
(I)
from any DC and USB loads connected.
Note:
The three DC5521, 12V ports (diameter 5.5mm) , are connected in parallel and provide a
maximum output current of 10A shared across these ports.
The single 24V DC5525 port has a maximum rated output current of 5A.
The large DC car socket should only be used for loads up to a maximum of 90W.
This provides voltage 13V,
±
1V, rated current at 10A output and automatically distributes current
according to the external equipment plugged into the socket.
2.3 Automatic Shutdown Mode
While the powerpack is in automatic shutdown mode, it will automatically deactivate the AC, DC and
USB outputs from the powerpack, if no consumption is detected after 5 minutes. The powerpack will
then shut down after 5 minutes if no buttons are pressed and the powerpack is not charging.
To enable / disable DC Automatic shutdown mode, ensure the powerpack is on and the display is
illuminated. Then simply hold the Power button and the DC button simultaneously for 5 seconds.
You will see the OUTPUT icon flash intermittently if you have done this correctly.
Repeating this process will deactivate the DC Automatic shutdown mode.
If the powerpack shuts down, automatic shutdown mode will be reactivated each time the
powerpack starts up, and will need to be disabled should you not want this to happen on start up.
More information can be found on our website www.portablepowertech.com.
Should your equire further information please contact Portable Power Technology;
You can reach us by emailing [email protected],
Or call us directly on 01474 761051.
5. Contact Information
Below are a list of error codes that appear on the front LCD planel.
Please contact Portable power technology for further assistance.
Note:
Do not attempt to dissasemble the product. Error codes
E10-13
are for internal use only.
6. Fault codes